An ultrasensitive micropillar-based quartz crystal microbalance device for real-time measurement of protein immobilization and protein-protein interaction

被引:33
|
作者
Su, Junwei [1 ]
Esmaeilzadeh, Hamed [1 ]
Zhang, Fang [2 ]
Yu, Qing [2 ]
Cernigliaro, George [3 ]
Xu, Jin [2 ]
Sun, Hongwei [1 ]
机构
[1] Univ Massachusetts, Dept Mech Engn, One Univ Ave, Lowell, MA 01854 USA
[2] Univ Massachusetts Lowell, Dept Chem, One Univ Ave, Lowell, MA 01854 USA
[3] MicroChem Corp, 200 Flanders Rd, Westborough, MA 01581 USA
来源
关键词
QCM; Micropillar; PMMA; Physical adsorption; Mass sensitivity improvement; Affinity; SURFACE-PLASMON RESONANCE; IMAGING MEASUREMENTS; HYBRIDIZATION ADSORPTION; STICKING PROBABILITIES; OPTICAL BIOSENSORS; DNA; LIQUID; MONOLAYERS; DESIGN;
D O I
10.1016/j.bios.2017.07.074
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A new sensing device was developed to achieve ultrahigh sensitivity, by coupling polymer micropillars with a quartz crystal microbalance (QCM) substrate to form a two-degree-of-freedom resonance system (QCM-P). The sensitivity of these QCM-P devices was evaluated by measuring mass changes for both deposited gold film and adsorption of bovine serum albumin (BSA), respectively, on poly(methyl methacrylate) (PMMA) micropillar surfaces, as well as assessing ligand-analyte binding interactions between anti-human immunoglobulin G (antihIgG) and human immunoglobulin G (hIgG). The anti-hIgG and hIgG binding results show QCM-P achieved an eightfold improvement in sensitivity relative to conventional QCM sensors. In addition, the binding affinity obtained from the QCM-P device for anti-hIgG and hIgG proteins was found in good agreement with that measured by surface plasmon resonance (SPR) for the same binding reaction.
引用
收藏
页码:325 / 331
页数:7
相关论文
共 50 条
  • [1] Lowest Detectable Protein Immobilization Measurement Using an Ultrasensitive Micropillar-Based Quartz Crystal Microbalance (QCM-P) Device
    Esmaeilzadeh, Hamed
    Su, Junwei
    Ji, Siqi
    Cernigliaro, George
    Gehring, Frank K.
    Sun, Hongwei
    IEEE SENSORS JOURNAL, 2019, 19 (21) : 9672 - 9679
  • [2] Protein-protein resistance investigated by quartz crystal microbalance
    Ma, Chunfeng
    Wu, Bo
    Zhang, Guangzhao
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2013, 104 : 5 - 10
  • [3] Real-time heterogeneous protein-protein interaction between αA-crystallin N-terminal mutants and αB-crystallin using quartz crystal microbalance (QCM)
    Ramkumar, Srinivasagan
    Fujii, Noriko
    Sakaue, Hiroaki
    Fujii, Norihiko
    Thankappan, Bency
    Kumari, Rasiah Pratheepa
    Natarajaseenivasan, Kalimuthusamy
    Anbarasu, Kumarasamy
    AMINO ACIDS, 2015, 47 (05) : 1035 - 1043
  • [4] Molecular aptamers for real-time protein-protein interaction study
    Cao, ZH
    Tan, WH
    CHEMISTRY-A EUROPEAN JOURNAL, 2005, 11 (15) : 4502 - 4508
  • [5] Covalent immobilization of protein on sensor crystals for the quartz crystal microbalance
    Sha, Xue
    Sun, Chengjun
    Alexander, Laura
    Loll, Patrick J.
    Penn, Lynn S.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2012, 244
  • [6] Real-time molecular recognition between protein and photosensitizer of photodynamic therapy by quartz crystal microbalance sensor
    Yang, Yu
    Long, Yuanyuan
    Li, Zhiyu
    Li, Na
    Li, Kean
    Liu, Feng
    ANALYTICAL BIOCHEMISTRY, 2009, 392 (01) : 22 - 27
  • [7] DEVELOPMENT OF A REAL-TIME GLUCOSE BIOSENSOR BY ENZYME IMMOBILIZATION ON THE QUARTZ CRYSTAL MICROBALANCE
    LASKY, SJ
    BUTTRY, DA
    AMERICAN BIOTECHNOLOGY LABORATORY, 1990, 8 (02): : 8 - &
  • [8] The use of a quartz crystal microbalance with dissipation for the measurement of protein-protein interactions:: a qualitative and quantitative analysis of the interactions between molecular chaperones
    Limson, J
    Odunuga, OO
    Green, H
    Höök, F
    Blatch, GL
    SOUTH AFRICAN JOURNAL OF SCIENCE, 2004, 100 (11-12) : 678 - 682
  • [9] An Automated Real Time System for FRET Based Protein-Protein Interaction Analysis
    Bernardini, A.
    Wotzlaw, C.
    Lipinski, H. -G.
    Fandrey, J.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 4: IMAGE PROCESSING, BIOSIGNAL PROCESSING, MODELLING AND SIMULATION, BIOMECHANICS, 2010, 25 : 1056 - 1058
  • [10] A quartz crystal microbalance biosensor for real-time detection of Salmonella Typhimurium based on antibody immobilization
    Min, Hyun Jung
    Cordoba, Hansel M.
    Deering, Amanda J.
    Robinson, J. Paul
    Bae, Euiwon
    SENSING FOR AGRICULTURE AND FOOD QUALITY AND SAFETY XIV, 2022, 12120