Comparison of hemostatic properties between collagen and synthetic buttress materials used in staple line reinforcement in a swine splenic hemorrhage model

被引:5
|
作者
Spector, David [1 ]
Perry, Zvi [2 ]
Konobeck, Tracy [3 ]
Mooradian, Daniel [3 ]
Shikora, Scott [1 ]
机构
[1] Tufts Med Ctr, Dept Surg, Boston, MA 02111 USA
[2] Soroka Univ Med Ctr, Dept Surg, Beer Sheva, Israel
[3] Synovis Life Technol, St Paul, MN USA
关键词
Staple-line reinforcement; Buttress; Hemostasis; Collagen; Synthetic polymer; Staple-line bleeding; Y GASTRIC BYPASS; N-ACETYL GLUCOSAMINE; LAPAROSCOPIC SLEEVE GASTRECTOMY; MORBID-OBESITY; ACHIEVING HEMOSTASIS; DUODENAL SWITCH; EXPERIENCE; MEMBRANE; AGENTS;
D O I
10.1007/s00464-010-1331-4
中图分类号
R61 [外科手术学];
学科分类号
摘要
The use of staplers in gastrointestinal surgery is widespread, especially in advanced laparoscopic procedures. Staple line reinforcement with a buttress reduces bleeding and associated complications through a combination of factors. The intrinsic hemostatic properties of buttress materials have not been examined. This study examined the intrinsic hemostatic properties of two different types of material used in buttressing in an accepted hemostasis model that does not involve stapling or its effects by compression. An acellular collagen buttress (Veritas(A (R))) and a synthetic polymer buttress (Duet (TM)) were compared to two commonly used hemostatic agents, Syvek(A (R)) and Surgicel(A (R)), with gauze as control. In a swine capsular stripping hemostasis model, a 1 x 1 cm section of spleen capsule was removed and used as a source of bleeding, with one patch of material tested per bleeding site. A total of 51 wounds were created in five pigs (each patch n = 10, control n = 11). Hemostatic efficacy was assessed by quantitating the number of applications and total time needed for bleeding to stop. The mean time needed for hemostasis for Syvek(A (R)) and Veritas(A (R)) patches was significantly less than gauze, Duet (TM) and Surgicel(A (R)) (4.02, 4.51 vs. 8.97, 9.22, and 10.30 min respectively; p < 0.05). The Syvek(A (R)) and Veritas(A (R)) patches required significantly fewer applications than gauze, Duet (TM) and Surgicel(A (R)) (1.7, 2.2 vs. 4.1, 4.6, and 4.9 respectively; p < 0.01). The intrinsic hemostatic properties of different buttressing materials vary widely. In this study, a collagen buttress was significantly better at promoting hemostasis than the synthetic buttress material in a nonstapling model. This could be another factor to consider when choosing a buttress for staple line reinforcement.
引用
收藏
页码:1148 / 1152
页数:5
相关论文
共 8 条
  • [1] Comparison of hemostatic properties between collagen and synthetic buttress materials used in staple line reinforcement in a swine splenic hemorrhage model
    David Spector
    Zvi Perry
    Tracy Konobeck
    Daniel Mooradian
    Scott Shikora
    Surgical Endoscopy, 2011, 25 : 1148 - 1152
  • [2] Tissue response to biomaterials used for staple-line reinforcement in lung resection - A comparison between expanded polytetrafluoroethylene and bovine pericardium
    Vaughn, CC
    Vaughn, PL
    Vaughn, CC
    Sawyer, P
    Manning, M
    Anderson, D
    Roseman, L
    Herbst, TJ
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1998, 13 (03) : 259 - 265
  • [3] Air leaks after surgical stapling in lung resection: A comparison between stapling alone and stapling with staple-line reinforcement materials in a canine model
    Roberson, LD
    Netherland, DE
    Dhillon, R
    Heath, BJ
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1998, 116 (02): : 353 - 354
  • [4] Tissue response to biomaterials used for staple-line reinforcement in lung resection - A comparison between expanded polytetrafluoroethylene and bovine pericardium - Appendix A. Conference discussion
    Von Segesser, L
    Vaughn, C
    Wolner, E
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1998, 13 (03) : 265 - 265
  • [5] Comparison of poly-N-acetyl glucosamine (P-GlcNAc) with absorbable collagen (Actifoam), and fibrin sealant (Bolheal) for achieving hemostasis in a swine model of splenic hemorrhage
    Chan, MW
    Schwaitzberg, SD
    Demcheva, M
    Vournakis, J
    Finkielsztein, S
    Connolly, RJ
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2000, 48 (03): : 454 - 457
  • [6] Comparison of poly-N-acetyl glucosamine (P-GlcNAc) with absorbable collagen (Actifoam), and fibrin sealant (Bolheal) for achieving hemostasis in a swine model of splenic hemorrhage -: Discussion
    Pasquale, MD
    Agarwal
    Holcomb
    Bergstein, JM
    Chan, M
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2000, 48 (03): : 457 - 458
  • [7] Comparison of Hemostatic Durability between N-Butyl Cyanoacrylate and Gelatin Sponge Particles in Transcatheter Arterial Embolization for Acute Arterial Hemorrhage in a Coagulopathic Condition in a Swine Model
    Takafumi Yonemitsu
    Nobuyuki Kawai
    Morio Sato
    Tetsuo Sonomura
    Isao Takasaka
    Motoki Nakai
    Hiroki Minamiguchi
    Shinya Sahara
    Yasuhiro Iwasaki
    Toshio Naka
    Masahiro Shinozaki
    CardioVascular and Interventional Radiology, 2010, 33 : 1192 - 1197
  • [8] Comparison of Hemostatic Durability between N-Butyl Cyanoacrylate and Gelatin Sponge Particles in Transcatheter Arterial Embolization for Acute Arterial Hemorrhage in a Coagulopathic Condition in a Swine Model
    Yonemitsu, Takafumi
    Kawai, Nobuyuki
    Sato, Morio
    Sonomura, Tetsuo
    Takasaka, Isao
    Nakai, Motoki
    Minamiguchi, Hiroki
    Sahara, Shinya
    Iwasaki, Yasuhiro
    Naka, Toshio
    Shinozaki, Masahiro
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2010, 33 (06) : 1192 - 1197