Optimization of vortex-assisted ionic liquid dispersive liquid-liquid microextraction by experimental design prior to hydride generation atomic absorption spectrometry for determination of selenium species in food, beverage and water samples

被引:18
|
作者
Altunay, Nail [1 ]
Elik, Adil [2 ]
Katin, Konstantin [3 ]
机构
[1] Sivas Cumhuriyet Univ, Fac Sci, Dept Biochem, TR-58140 Sivas, Turkey
[2] Sivas Cumhuriyet Univ, Fac Sci, Dept Chem, TR-58140 Sivas, Turkey
[3] Natl Res Nucl Univ MEPhI, Inst Nanoengn Elect Spintron & Photon, Kashirskoe Shosse 31, Moscow 115409, Russia
关键词
Selenium; Experimental design; Food analysis; Food composition; Room temperature ionic liquid; Hydride generation atomic absorption spectrometry; DEEP EUTECTIC SOLVENT; INORGANIC SELENIUM; SPECTROPHOTOMETRIC DETERMINATION; SPECIATION; EXTRACTION; PRECONCENTRATION; PLASMA;
D O I
10.1016/j.jfca.2021.103871
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
We applied novel vortex-assisted ionic liquid dispersive liquid-liquid microextraction (VA-IL-DLLME) method to preconcentration and extraction of Se(IV) ions from water, beverage and food samples. The method was optimized using central composite design combined with the response surface analysis. After extraction, inorganic selenium species (total Se, Se(IV) and Se(VI)) were determined by hydride generation atomic absorption spectrometry. 1-n-Octyl-3-methylimidazolium bis(trifluoromethane)-sulfonamide [C8mim NTf2] and tetrahydrofuran were used as the extraction and dispersive solvents, respectively. Applied vortex assisted the extractant dispersion and accelerated the mass transfer process. Obtained optimum conditions for microextraction procedure are as follows: mass of [C8mim NTf2], pH, extraction time and THF volume should be equal to 85 mg, 6.8, 15 min and 730 mu L, respectively. Under these conditions, we observed linear range, limit of detection and enrichment factor equal to 5-500ng L-1, 1.5 ng L-1 and 120, respectively. We also fount linear regression coefficients in the dependence between Absorbance and Se(IV) concentration: Absorbance = 0.0652 C-Se(IV) + 0.0185. We added 200 mu g kg(-1) of Se(IV) to selected food samples and 100 ng L-1 of Se(IV) to selected waters and beverages. Relative standard deviations and recovery values were within the ranges of 2.4-3.5 % and 92.7 divided by 103.4 %, respectively. The optimized VA-IL-DLLME method reported here provides high extraction efficiency, fast extraction and lower detection limit without a heating step than alternative microextraction methods. This method also requires environmental solvents for determination and preconcentration of trace Se species in the selected samples. In addition, the reported VA-IL-DLLME procedure is the first method which use [C8mim NTf2] as extraction solvent for the preconcentration and separation of Se(IV) ions.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Liquid-Liquid Microextraction with Vortex-Assisted for Determination of Palladium and Gold in Water Samples by Flame Atomic Absorption Spectrometry
    Zhao, Jiao
    Meng, Lifen
    Cheng, Jia Xi
    Yang, Yaling
    ASIAN JOURNAL OF CHEMISTRY, 2014, 26 (07) : 2027 - 2030
  • [2] Determination and Speciation of Selenium Species in Real Water and Food Samples Using Dispersive Liquid-liquid Microextraction and Electrothermal Atomic Absorption Spectrometry
    Uluozlu, Ozgur Dogan
    ATOMIC SPECTROSCOPY, 2019, 40 (04) : 133 - 138
  • [3] Vortex-assisted switchable liquid-liquid microextraction for the preconcentration of cadmium in environmental samples prior to its determination with flame atomic absorption spectrometry
    Merve Fırat
    Süleyman Bodur
    Büşra Tışlı
    Cansu Özlü
    Dotse Selali Chormey
    Fatma Turak
    Sezgin Bakırdere
    Environmental Monitoring and Assessment, 2018, 190
  • [4] Vortex-assisted switchable liquid-liquid microextraction for the preconcentration of cadmium in environmental samples prior to its determination with flame atomic absorption spectrometry
    Firat, Merve
    Bodur, Suleyman
    Tisli, Busra
    Ozlu, Cansu
    Chormey, Dotse Selali
    Turak, Fatma
    Bakirdere, Sezgin
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2018, 190 (07)
  • [5] Determination of Total Arsenic in Water and Food Samples by Pressure-induced Ionic Liquid-based Dispersive Liquid-Liquid Microextraction Method Prior to Analysis by Hydride Generation Atomic Absorption Spectrometry
    Ali, Jamshed
    Tuzen, Mustafa
    Kazi, Tasneem Gul
    ATOMIC SPECTROSCOPY, 2017, 38 (02) : 57 - 64
  • [6] Ionic liquid-assisted separation and determination of selenium species in food and beverage samples by liquid chromatography coupled to hydride generation atomic fluorescence spectrometry
    Grijalba, Alexander Castro
    Fiorentini, Emiliano F.
    Wuilloud, Rodolfo G.
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1491 : 117 - 125
  • [7] Optimization of magnetic ionic based dispersive liquid-liquid microextraction of cadmium in water and food samples using experimental design prior to flame atomic absorption spectrophotometry
    Elik, Adil
    Altunay, Nail
    SUSTAINABLE CHEMISTRY AND PHARMACY, 2022, 27
  • [8] A simple and sensitive vortex-assisted ionic liquid-dispersive microextraction and spectrophotometric determination of selenium in food samples
    Bagda, Esra
    Tuezen, Mustafa
    FOOD CHEMISTRY, 2017, 232 : 98 - 104
  • [9] Extraction and preconcentration of trace Al and Cr from vegetable samples by vortex-assisted ionic liquid-based dispersive liquid-liquid microextraction prior to atomic absorption spectrometric determination
    Altunay, Nail
    Yildirim, Emre
    Gurkan, Ramazan
    FOOD CHEMISTRY, 2018, 245 : 586 - 594
  • [10] Determination of Copper in Food and Water by Dispersive Liquid-Liquid Microextraction and Flame Atomic Absorption Spectrometry
    Al Othman, Zeid
    Unsal, Yunus Emre
    Habila, Mohamed
    Shabaka, Aza
    Tuzen, Mustafa
    Soylak, Mustafa
    ANALYTICAL LETTERS, 2015, 48 (11) : 1738 - 1750