Wigner-Ville distribution applied to cardiac motion estimation

被引:0
|
作者
Meyering, WI [1 ]
Gutierrez, MA [1 ]
Furuie, SS [1 ]
Rebelo, MS [1 ]
Melo, CP [1 ]
机构
[1] Univ Sao Paulo, Sch Med, InCor, Sao Paulo, Brazil
来源
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Some heart abnormalities like ischemia and infarction of myocardium can produce significant changes in cardiac wall motion and decrease severely the cardiac function. For this reason the cardiac motion estimation and quantification have been the focus of many investigations. The aim of this work is to study cardiac motion by means a dense velocity vector field based on the computation of the Wigner-Ville distribution, a common transformation used in the spatiotemporal-frequency (STF) analysis. The major motivation for considering the use of STF comes from observations in mammalian vision This paper describes a method to obtain a 3D-frequency spectrum, based on the computation of the Wigner-Ville distribution and a procedure to determine, automatically, the velocity of pixels in a temporal series of images. The method is also applied to synthetic images and real images obtained from gated-SPECT.
引用
收藏
页码:619 / 622
页数:4
相关论文
共 50 条
  • [1] The Wigner-Ville distribution and the cross Wigner-Ville distribution of noisy signals
    Chen Guanhua
    Ma Shiwei
    Qin Tinghao
    Wang Jian
    Cao Jialin
    2006 8TH INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING, VOLS 1-4, 2006, : 231 - +
  • [2] Statistical Performance of the Wigner-Ville Distribution and the Cross Wigner-Ville Distribution
    陈光化
    曹家麟
    Journal of Shanghai University, 2003, (04) : 379 - 383
  • [4] Wigner-Ville distribution and cross Wigner-Ville distribution of noisy signals
    Chen Guanghua
    Ma Shiwei
    Liu Ming
    Zhu Jingming
    Zeng Weimin
    JOURNAL OF SYSTEMS ENGINEERING AND ELECTRONICS, 2008, 19 (05) : 1053 - 1057
  • [5] Statistical performance of Wigner-Ville distribution and windowed Wigner-Ville distribution
    Qui, Lunji
    IEEE Transactions on Signal Processing, 1993, 41 (11)
  • [6] Motion estimation of magnetic resonance cardiac images using the Wigner-Ville and Hough Transforms
    Carranza, N.
    Cristobal, G.
    Bayerl, P.
    Neumann, H.
    OPTICS AND SPECTROSCOPY, 2007, 103 (06) : 877 - 885
  • [7] Motion estimation of magnetic resonance cardiac images using the Wigner-Ville and hough transforms
    N. Carranza
    G. Cristóbal
    P. Bayerl
    H. Neumann
    Optics and Spectroscopy, 2007, 103 : 877 - 885
  • [8] Spatio-temporal motion estimation using the Wigner-Ville distribution and the Hough transform
    Carranza-Herrezuelo, N.
    Gil-Rodrigo, E.
    Cristobal, G.
    Ledesma-Carbayoo, M. J.
    Santos, A.
    PERCEPTION, 2007, 36 : 214 - 214
  • [9] Wigner-Ville and polynomial wigner-ville transforms in the estimation of nonlinear FM signal parameters
    De Luigi, C
    Moreau, E
    2002 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING, VOLS I-IV, PROCEEDINGS, 2002, : 1433 - 1436
  • [10] BIAS ERROR DUE TO WINDOWS FOR THE WIGNER-VILLE DISTRIBUTION ESTIMATION
    PARK, YK