Safety and efficacy of frequency domain optical coherence tomography in pigs

被引:3
|
作者
Li, Xiankai [1 ,2 ]
Villard, Joseph W. [1 ]
Ouyang, Yongjian
Michalek, Joel E.
Jabara, Refat [3 ,4 ]
Sims, Dan [5 ]
Kemp, Nate [5 ]
Glynn, Tim [5 ]
Banas, Christopher [5 ]
Bailey, Steven R. [1 ]
Feldman, Marc D. [1 ,6 ]
机构
[1] Univ Texas Hlth Sci Ctr San Antonio, Janey Briscoe Div Cardiol, San Antonio, TX 78229 USA
[2] Tongji Univ, Sch Med, Dept Cardiol, Shanghai Peoples Hosp 10, Shanghai 200092, Peoples R China
[3] Hadassah Hebrew Univ, Med Ctr, Jerusalem, Israel
[4] St Josephs Translat Res Inst, Atlanta, GA USA
[5] Volcano Corp, Billerica, MA USA
[6] S Texas Vet Hlth Care Syst, San Antonio, TX USA
关键词
optical coherence tomography; safety; efficacy; frequency domain; CORONARY STENT SYSTEM; NANOTHIN POLYZENE-F; ARTERY LESIONS; PLAQUES;
D O I
10.4244/EIJV7I4A80
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: To determine the safety and efficacy of frequency domain OCT, which can scan at much higher rates and make it possible to avoid an occlusion balloon and image during an angiographic injection through guide catheter. The catheters have diameters ranging from 2.7 to 3.5 Fr. The presence of the imaging catheter increases fluid resistance to the injection of viscous solutions necessary for clearing the blood. Methods and results: The Volcano 3.5 Fr frequency domain OCT catheter system was investigated for safety in (a) n=10 porcine studies using acute and 30-day histology, and (b) for efficacy in n=9 in vivo porcine coronary arteries. We found: (a) frequency domain imaging is safe in the porcine model using histology as an endpoint; (b) the addition of a viscous contrast (iodixonal) to saline is superior for lumen clearance compared to saline alone; (c) hand injection, 4 ml/sec, and 6 ml/sec power injection all provided similar vessel wall clearance; (d) the anticipated loss of vessel wall visualisation with left main injection (due to half the injectate in the non-imaged vessel) was not evident in proximal and middle coronary artery OCT catheter positions. Conclusions: Frequency domain OCT is safe and efficacious in the porcine model.
引用
收藏
页码:497 / 504
页数:8
相关论文
共 50 条
  • [1] Safety and efficacy of frequency-domain optical coherence tomography in evaluating and treating intermediate coronary lesions
    Khurwolah, Mohammad Reeaze
    Meng, Hao-Yu
    Wang, Yong-Sheng
    Wang, Lian-Sheng
    Kong, Xiang-Qing
    WORLD JOURNAL OF CARDIOLOGY, 2018, 10 (11): : 222 - 233
  • [2] A versatile frequency domain multiplexer for optical coherence tomography
    Zurauskas, Mantas
    Podoleanu, Adrian Gh.
    Proceedings of SPIE - The International Society for Optical Engineering, 2013, 8914
  • [3] A versatile frequency domain multiplexer for optical coherence tomography
    Zurauskas, Mantas
    Podoleanu, Adrian Gh.
    INTERNATIONAL SYMPOSIUM ON PHOTOELECTRONIC DETECTION AND IMAGING 2013: FIBER OPTIC SENSORS AND OPTICAL COHERENCE TOMOGRAPHY, 2013, 8914
  • [4] Frequency domain second harmonic optical coherence tomography
    Su, Jianping
    Tomov, I. V.
    Jiang, Y.
    Chen, Zhongping
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE X, 2006, 6079
  • [5] Feasibility and Safety of the Novel Vivolight Frequency Domain Optical Coherence Tomography System: A Multicenter Study
    Jin, Qinhua
    Qian, Juying
    Zhou, Yujie
    Jing, Jing
    Wu, Yizhe
    Liu, Yuyang
    Shen, Hua
    Guo, Jun
    Sun, Zhijun
    Wang, Yu
    Chen, Lian
    Chen, Yundai
    JOURNAL OF INVASIVE CARDIOLOGY, 2021, 33 (06): : E412 - E416
  • [6] Fourier domain optical coherence tomography using optical frequency comb
    Bajraszewski, T.
    Wojtkowski, M.
    Szkulmowska, A.
    Fojt, W.
    Szkulmowski, M.
    Kowalczyk, A.
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE XI, 2007, 6429
  • [7] Assessing the efficacy of saline flush in frequency-domain optical coherence tomography for intracoronary imaging
    Kimura, Masahiro
    Takeda, Teruki
    Tsujino, Yasushi
    Matsumoto, Yuichi
    Yamaji, Masayuki
    Sakaguchi, Tomoko
    Maeda, Keiko
    Mabuchi, Hiroshi
    Murakami, Tomoyuki
    HEART AND VESSELS, 2024, 39 (04) : 310 - 318
  • [8] Assessing the efficacy of saline flush in frequency-domain optical coherence tomography for intracoronary imaging
    Masahiro Kimura
    Teruki Takeda
    Yasushi Tsujino
    Yuichi Matsumoto
    Masayuki Yamaji
    Tomoko Sakaguchi
    Keiko Maeda
    Hiroshi Mabuchi
    Tomoyuki Murakami
    Heart and Vessels, 2024, 39 : 310 - 318
  • [9] Optical coherence tomography by using frequency measurements in wavelength domain
    Seck, Hon Luen
    Zhang, Ying
    Soh, Yeng Chai
    OPTICS EXPRESS, 2011, 19 (02): : 1324 - 1334
  • [10] Depth resolved spectroscopy by frequency domain optical coherence tomography
    Leitgeb, R
    Wojtkowski, M
    Hitzenberger, CK
    Fercher, AF
    Sticker, M
    Kowalczyk, A
    PHOTON MIGRATION, DIFFUSE SPECTROSCOPY AND OPTICAL COHERENCE TOMOGRAPHY: IMAGING AND FUNCTIONAL ASSESSMENT, 2000, 4160 : 57 - 62