Determinants of nitrogen dioxide concentrations in indoor ice skating rinks

被引:27
|
作者
Levy, JI
Lee, K
Yanagisawa, Y
Hutchinson, P
Spengler, JD
机构
[1] Harvard Univ, Sch Publ Hlth, Dept Environm Hlth, Boston, MA 02115 USA
[2] Queensland Univ Technol, Sch Publ Hlth, Brisbane, Qld, Australia
[3] Univ Tokyo, Fac Engn, Tokyo 113, Japan
[4] Metropolitan Dist Commiss, Boston, MA USA
关键词
D O I
10.2105/AJPH.88.12.1781
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Objectives. The combination of poor ventilation and fuel-powered ice resurfacers has resulted in elevated nitrogen dioxide (NO2) concentrations in many indoor ice skating rinks. This study examined the factors influencing; concentrations and the effects of various engineering controls in ice rinks with different resurfacer fuels. Methods. Indoor NO2 concentrations were measured in 19 enclosed ice skating rinks over 3 winters by means of passive samplers, with 1-week average measurements during the first winter pilot study and single-day working-hour measurements in the final 2 winters. Personal exposures to drivers also were assessed during the last winter. Results. Rinks in which propane-fueled resurfacers were used had a daily mean indoor NO2 concentration of 206 ppb, compared with 1 32 ppb for gasoline-fueled and 37 ppb for electric-powered resurfacers. Engineering controls, such as increased ventilation and resurfacer tuning, reduced NO2 concentrations by 65% on average, but outcomes varied widely, and concentrations increased in subsequent months. Conclusions. Electric ice resurfacers, increased ventilation; or emission control systems are recommnended to protect the health of workers and patrons, with surveillance programs proposed to track implementation and maintain an observer effect.
引用
收藏
页码:1781 / 1786
页数:6
相关论文
共 50 条
  • [1] NITROGEN-DIOXIDE EXPOSURES INSIDE ICE SKATING RINKS
    BRAUER, M
    SPENGLER, JD
    AMERICAN JOURNAL OF PUBLIC HEALTH, 1994, 84 (03) : 429 - 433
  • [2] Surveillance of indoor air quality in ice skating rinks
    Yoon, DW
    Lee, KY
    Yanagisawa, Y
    Spengler, JD
    Hutchinson, P
    ENVIRONMENT INTERNATIONAL, 1996, 22 (03) : 309 - 314
  • [3] Indoor air quality in ice skating rinks in Hong Kong
    Guo, H
    Lee, SC
    Chan, LY
    ENVIRONMENTAL RESEARCH, 2004, 94 (03) : 327 - 335
  • [4] Nitrogen dioxide in indoor ice skating facilities: An international survey
    Brauer, M
    Lee, KY
    Spengler, JD
    Salonen, RO
    Pennanen, A
    Braathen, OA
    Mihalikova, E
    Miskovic, P
    Nozaki, A
    Tsuzuki, T
    Song, RJ
    Yang, X
    Zeng, QX
    Drahonovska, H
    Kjaergaard, S
    JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1997, 47 (10): : 1095 - 1102
  • [5] MODERNIZING AND RETROFITTING ICE SKATING RINKS
    BLADES, RW
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1992, 34 (04): : 34 - &
  • [6] Influence of Advertising Banners and Team Logos on the Temperature Regime of Ice of Indoor Ice Skating Rinks, Built Into the Ice Plate
    Livanskiy, D. G.
    SCIENCE & TECHNIQUE, 2023, 22 (06): : 500 - 507
  • [8] CARBON-MONOXIDE IN INDOOR ICE SKATING RINKS - EVALUATION OF ABSORPTION BY ADULT HOCKEY PLAYERS
    LEVESQUE, B
    DEWAILLY, E
    LAVOIE, R
    PRUDHOMME, D
    ALLAIRE, S
    AMERICAN JOURNAL OF PUBLIC HEALTH, 1990, 80 (05) : 594 - 598
  • [9] STUDIES OF PROPERTIES OF ICE IN SPEED-SKATING RINKS
    KOBAYASHI, T
    ASHRAE JOURNAL, 1973, 15 (01) : 51 - 56
  • [10] Blades of Glory ICE SKATING RINKS IN HISTORIC SETTINGS
    Flynn, Katherine
    Keane, Katharine
    PRESERVATION, 2017, 69 (01): : 52 - 53