Determination of cardamonin using a chemiluminescent flow-injection method

被引:6
|
作者
Zhang, QL [1 ]
Myint, A [1 ]
Cui, H [1 ]
Ge, XW [1 ]
Liu, LJ [1 ]
Chou, GX [1 ]
机构
[1] Univ Sci & Technol China, Dept Chem, Hefei 230026, Anhui, Peoples R China
关键词
flow injection; chemiluminescence; cardamonin; cerium (IV); rhodamine; 6G; Alpinia katsumadai Hayata;
D O I
10.1002/pca.867
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A sensitive and selective flow injection chemiluminescence method for the determination of cardamonin over the range 1.0 x 10(-8) to 8.0 x 10(-6) g/mL is described. The method is based on the enhancement by cardamonin of the chemiluminescence of the reaction between cerium (TV) and rhodamine 6G in sulphuric acid medium. The optimised flow injection procedure yielded a detection limit for cardamonin of 8.8 x 10(-9) g/mL, whilst the relative standard deviations of intraday and inter-day precision were below 2.5%. The method has the advantages of high sensitivity and a wide linear range. It was successfully applied to the determination of cardamonin in Alpinia katsumadai Hayata. The mechanism of the chemiluminescence reaction is proposed. Copyright (c) 2005 John Wiley & Sons, Ltd.
引用
收藏
页码:440 / 445
页数:6
相关论文
共 50 条
  • [1] Determination of tiopronin in pharmaceuticals using a chemiluminescent flow-injection method
    Perez-Ruiz, T
    Martinez-Lozano, C
    Baeyens, WRG
    Sanz, A
    San-Miguel, MT
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 17 (4-5) : 823 - 828
  • [2] DETERMINATION OF VOLATILE PHENOLS BY A FLOW-INJECTION CHEMILUMINESCENT QUENCH METHOD
    ZHUANG, HS
    ZHANG, F
    WANG, QE
    [J]. ANALYST, 1995, 120 (01) : 121 - 124
  • [3] Photokinetic determination of phenothiazine dyes by a flow-injection chemiluminescent method
    PerezRuiz, T
    MartinezLozano, C
    Tomas, V
    Sanz, A
    [J]. QUIMICA ANALITICA, 1996, 15 (04): : 326 - 333
  • [4] SENSITIZED DETERMINATION OF SULFITE USING FLOW-INJECTION WITH CHEMILUMINESCENT DETECTION
    PAULLS, DA
    TOWNSHEND, A
    [J]. ANALYST, 1995, 120 (02) : 467 - 469
  • [5] SENSITIVE DETERMINATION OF MANGANESE USING FLOW-INJECTION AND CHEMILUMINESCENT DETECTION
    BOWIE, AR
    FIELDEN, PR
    LOWE, RD
    SNOOK, RD
    [J]. ANALYST, 1995, 120 (08) : 2119 - 2127
  • [6] Determination of carbofuran by flow-injection with chemiluminescent detection
    Xie, ZH
    Ouyang, XQ
    Guo, LQ
    Lin, XC
    Chen, GN
    [J]. LUMINESCENCE, 2005, 20 (03) : 226 - 230
  • [7] CHEMILUMINESCENT METHOD FOR FLOW-INJECTION ANALYSIS OF ANIONS
    COOPER, MM
    SPURLIN, SR
    [J]. ANALYTICAL LETTERS, 1986, 19 (23-24) : 2221 - 2230
  • [8] CHEMILUMINESCENT AND SPECTROPHOTOMETRIC DETERMINATION OF PEROXIDASE AND LACTOPEROXIDASE IN FOODS USING FLOW-INJECTION
    PUCHADES, R
    MAQUIEIRA, A
    PLANTA, M
    RUIZ, D
    [J]. ANALUSIS, 1994, 22 (02) : 76 - 81
  • [9] Flow-injection determination of glucose by a photoinduced chemiluminescent reaction
    Pérez-Ruíz, T
    Martínez-Lozano, C
    Tomás, V
    Sanz, A
    [J]. ANALYTICAL LETTERS, 1998, 31 (11) : 1837 - 1855
  • [10] Flow-injection chemiluminescent determination of trace nitrite in water
    Wang, XF
    Shi, X
    Pi, YQ
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2005, 33 (06) : 865 - 868