Potentiometric micro determination of some metal ions using chloranilate PVC matrix membrane electrodes.

被引:10
|
作者
Elmosallamy, MAF
机构
[1] Chemistry Department, Faculty of Science, Zagazig University, Zagazig
关键词
chloranilate ion selective electrodes; solvent mediators; potentiometric titration; metal ion determination;
D O I
10.1080/00032719708001795
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Chloranilate PVC matrix membrane electrodes have been developed. These are based on the use of aliquat-chloranilate ion pair in plasticized PVC matrices. The calibration slope is about 60 mV/decade. The limit of detection is about 10(-5) M, the working pH range is 5-10, the electrodes have been used in the determination of lead, mercury, and cadmium ions with chloranilic acid, separately and in binary mixtures. 2-Nitro phenyl octyl ether, 2-nitro phenyl phenyl ether, dioctyl phthalate, dioctylsebacate, dioctyl phenyl phosphonate plasticizers are used; there were no significant differences in the performance characteristics of membranes for the various plasticizers. The life time of the electrodes is greater than one month.
引用
收藏
页码:475 / 487
页数:13
相关论文
共 50 条
  • [1] PVC membrane electrodes for potentiometric determination of tripelennamine
    ElNemma, EM
    MIKROCHIMICA ACTA, 1997, 127 (3-4) : 259 - 263
  • [2] PVC membrane electrodes for potentiometric determination of tripelennamine
    Eman M. El Nemma
    Microchimica Acta, 1997, 127 : 259 - 263
  • [3] POTENTIOMETRIC DETERMINATION OF CATIONIC SURFACTANTS USING PVC MEMBRANE BASED SURFACTANT ELECTRODES
    ZELENKA, L
    SAKBOSNAR, M
    MAREK, N
    KOVACS, B
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1989, 334 (07): : 706 - 706
  • [4] PVC matrix membrane sensor for potentiometric determination of dodecylsulfate
    Mostafa, Gamal A. E.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2008, 88 (06) : 435 - 446
  • [5] PVC MATRIX MEMBRANE SENSORS FOR POTENTIOMETRIC DETERMINATION OF ARECOLINE
    Abounassif, A.
    Al-Hadiya, B. M.
    Mostafa, Gamal A. E.
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2010, 38 (02) : 165 - 177
  • [6] POTENTIOMETRIC ESTIMATION OF METAL-IONS USING MEMBRANE AS INDICATOR ELECTRODES
    ADHIKARI, M
    GANGOPADHYAY, D
    SEN, G
    JOURNAL OF THE INDIAN CHEMICAL SOCIETY, 1975, 52 (12) : 1136 - 1138
  • [7] PVC matrix membrane sensor for potentiometric determination of metoclopramide hydrochloride in some pharmaceutical formulations
    Mostafa, GAE
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 31 (03) : 515 - 521
  • [8] Potentiometric determination of moxifloxacin in some pharmaceutical formulation using PVC membrane sensors
    Mohammed M Hefnawy
    Atef M Homoda
    Mohammed A Abounassif
    Amer M Alanazi
    Abdulrahaman Al-Majed
    Gamal A Mostafa
    Chemistry Central Journal, 8
  • [9] Potentiometric determination of moxifloxacin in some pharmaceutical formulation using PVC membrane sensors
    Hefnawy, Mohammed M.
    Homoda, Atef M.
    Abounassif, Mohammed A.
    Alanazi, Amer M.
    Al-Majed, Abdulrahaman
    Mostafa, Gamal A.
    CHEMISTRY CENTRAL JOURNAL, 2014, 8
  • [10] PVC Matrix Membrane Sensor for Potentiometric Determination of Cetylpyridinium Chloride
    Gamal A. E. Mostafa
    Analytical Sciences, 2001, 17 : 1043 - 1047