Regional assessment of carotid artery pulse wave velocity using compressed sensing accelerated high temporal resolution 2D CINE phase contrast cardiovascular magnetic resonance

被引:18
|
作者
Peper, Eva S. [1 ]
Strijkers, Gustav J. [2 ]
Gazzola, Katja [3 ]
Potters, Wouter V. [4 ]
Motaal, Abdallah G. [5 ]
Luirink, Ilse K. [6 ,7 ]
Hutten, Barbara A. [6 ]
Wiegman, Albert [7 ]
van Ooij, Pim [1 ]
van den Born, Bert-Jan H. [3 ]
Nederveen, Aart J. [1 ]
Coolen, Bram F. [2 ]
机构
[1] Univ Amsterdam, Amsterdam UMC, Dept Radiol & Nucl Med, Amsterdam, Netherlands
[2] Univ Amsterdam, Dept Biomed Engn & Phys, Amsterdam UMC, Amsterdam, Netherlands
[3] Univ Amsterdam, Dept Vasc Med, Amsterdam UMC, Amsterdam, Netherlands
[4] Univ Amsterdam, Amsterdam UMC, Dept Neurol, Amsterdam, Netherlands
[5] Philips Healthcare, Image Guided Therapy, Singapore, Singapore
[6] Univ Amsterdam, Amsterdam UMC, Dept Clin Epidemiol Biostat & Bioinformat, Amsterdam, Netherlands
[7] Univ Amsterdam, Amsterdam UMC, Emma Childrens Hosp, Dept Pediat, Amsterdam, Netherlands
关键词
Arterial stiffness; Pulse wave velocity; Compressed sensing; Phasecontrast MRI; Carotid atherosclerosis; MRI; FLOW; RISK; ATHEROSCLEROSIS; REPRODUCIBILITY; PLAQUE;
D O I
10.1186/s12968-018-0499-y
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundCardiovascular magnetic resonance (CMR) allows for non-invasive assessment of arterial stiffness by means of measuring pulse wave velocity (PWV). PWV can be calculated from the time shift between two time-resolved flow curves acquired at two locations within an arterial segment. These flow curves can be derived from two-dimensional CINE phasecontrast CMR (2D CINE PC CMR). While CMR-derived PWV measurements have proven to be accurate for the aorta, this is more challenging for smaller arteries such as the carotids due to the need for both high spatial and temporal resolution. In this work, we present a novel method that combines retrospectively gated 2D CINE PC CMR, high temporal binning of data and compressed sensing (CS) reconstruction to accomplish a temporal resolution of 4ms. This enables accurate flow measurements and assessment of PWV in regional carotid artery segments.MethodsRetrospectively gated 2D CINE PC CMR data acquired in the carotid artery was binned into cardiac frames of 4ms length, resulting in an incoherently undersampled k(y)-t-space with a mean undersampling factor of 5. The images were reconstructed by a non-linear CS reconstruction using total variation over time as a sparsifying transform. PWV values were calculated from flow curves by using foot-to-foot and cross-correlation methods. Our method was validated against ultrasound measurements in a flow phantom setup representing the carotid artery. Additionally, PWV values of two groups of 23 young (303years, 12 [52%] women) and 10 elderly (6210years, 5 [50%] women) healthy subjects were compared using the Wilcoxon rank-sum test.ResultsOur proposed method produced very similar flow curves as those measured using ultrasound at 1ms temporal resolution. Reliable PWV estimation proved possible for transit times down to 7.5ms. Furthermore, significant differences in PWV values between healthy young and elderly subjects were found (4.7 +/- 1.0m/s and 7.9 +/- 2.4m/s, respectively; p<0.001) in accordance with literature.Conclusions>Retrospectively gated 2D CINE PC CMR with CS allows for high spatiotemporal resolution flow measurements and accurate regional carotid artery PWV calculations. We foresee this technique will be valuable in protocols investigating early development of carotid atherosclerosis.
引用
收藏
页数:12
相关论文
共 24 条
  • [1] Regional assessment of carotid artery pulse wave velocity using compressed sensing accelerated high temporal resolution 2D CINE phase contrast cardiovascular magnetic resonance
    Eva S. Peper
    Gustav J. Strijkers
    Katja Gazzola
    Wouter V. Potters
    Abdallah G. Motaal
    Ilse K. Luirink
    Barbara A. Hutten
    Albert Wiegman
    Pim van Ooij
    Bert-Jan H. van den Born
    Aart J. Nederveen
    Bram F. Coolen
    Journal of Cardiovascular Magnetic Resonance, 20
  • [2] Pulse wave dynamics in the carotid artery: assessment with high field velocity-encoded magnetic resonance imaging
    Kroner, E. S. J.
    Lamb, H. J.
    Siebelink, H. J.
    Wall, E. E.
    Van der Grond, J.
    Van Buchem, M. A.
    De Roos, A.
    Westenberg, J. J. M.
    EUROPEAN HEART JOURNAL, 2012, 33 : 257 - 257
  • [3] Use of Compressed Sensing Accelerated, Low-Velocity Encoded, Isotropic Resolution, Phase Contrast Magnetic Resonance Angiography for SEEG Electrode Implantation
    Liu, Qiangqiang
    Lin, Zengping
    Shen, Yiwen
    Zhu, Jiachen
    Song, Jian
    Zhang, Chencheng
    Lu, Yong
    Xu, Jiwen
    WORLD NEUROSURGERY, 2024, 181 : E18 - E28
  • [4] Rapid 2D phase-contrast magnetic resonance angiography reconstruction algorithm via compressed sensing
    Dong-Hoon Lee
    Cheol-Pyo Hong
    Man-Woo Lee
    Bong-Soo Han
    Journal of the Korean Physical Society, 2013, 63 : 1072 - 1076
  • [5] Rapid 2D phase-contrast magnetic resonance angiography reconstruction algorithm via compressed sensing
    Lee, Dong-Hoon
    Hong, Cheol-Pyo
    Lee, Man-Woo
    Han, Bong-Soo
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2013, 63 (05) : 1072 - 1076
  • [6] Accurate assessment of carotid artery stenosis in atherosclerotic mice using accelerated high-resolution 3D magnetic resonance angiography
    Ratering, David
    Baltes, Christof
    Lohmann, Christine
    Matter, Christian M.
    Rudin, Markus
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2011, 24 (01) : 9 - 18
  • [7] Accurate assessment of carotid artery stenosis in atherosclerotic mice using accelerated high-resolution 3D magnetic resonance angiography
    David Ratering
    Christof Baltes
    Christine Lohmann
    Christian M. Matter
    Markus Rudin
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2011, 24 : 9 - 18
  • [8] High spatial and temporal resolution black-blood dynamic contrast-enhanced carotid artery wall MRI using compressed sensing
    Zheng-Wei Zhou
    Behzad Sharif
    Zhaoyang Fan
    Yibin Xie
    Debiao Li
    Journal of Cardiovascular Magnetic Resonance, 16 (Suppl 1)
  • [9] High Spatial and Temporal Resolution Dynamic Contrast-Enhanced Magnetic Resonance Angiography Using Compressed Sensing with Magnitude Image Subtraction
    Rapacchi, Stanislas
    Han, Fei
    Natsuaki, Yutaka
    Kroeker, Randall
    Plotnik, Adam
    Lehrman, Evan
    Sayre, James
    Laub, Gerhard
    Finn, J. Paul
    Hu, Peng
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (05) : 1771 - 1783
  • [10] Quantitative measurements on the human ascending aortic flow using 2D cine phase-contrast magnetic resonance imaging
    Yokosawa, S
    Nakamura, M
    Wada, S
    Isoda, H
    Takeda, H
    Yamaguchi, T
    JSME INTERNATIONAL JOURNAL SERIES C-MECHANICAL SYSTEMS MACHINE ELEMENTS AND MANUFACTURING, 2005, 48 (04) : 459 - 467