A Generator-Produced Gallium-68 Radiopharmaceutical for PET Imaging of Myocardial Perfusion

被引:25
|
作者
Sharma, Vijay [1 ,2 ]
Sivapackiam, Jothilingam [1 ]
Harpstrite, Scott E. [1 ]
Prior, Julie L. [1 ]
Gu, Hannah [1 ]
Rath, Nigam P. [5 ]
Piwnica-Worms, David [1 ,3 ,4 ]
机构
[1] Washington Univ, Sch Med, Edward Mallinckrodt Inst Radiol, BRIGHT Inst,Mol Imaging Ctr, St Louis, MO 63110 USA
[2] Washington Univ, Sch Med, Dept Biomed Engn, St Louis, MO USA
[3] Washington Univ, Sch Med, Dept Cell Biol & Physiol, St Louis, MO 63110 USA
[4] Washington Univ, Sch Med, Dept Dev Biol, St Louis, MO USA
[5] Univ Missouri, Dept Chem & Biochem, St Louis, MO 63121 USA
来源
PLOS ONE | 2014年 / 9卷 / 10期
基金
美国国家卫生研究院;
关键词
MDR1; P-GLYCOPROTEIN; BLOOD-BRAIN-BARRIER; MULTIDRUG-RESISTANCE; GALLIUM(III) COMPLEXES; BIOLOGICAL EVALUATION; TRANSPORT; AGENTS; METAL; TECHNETIUM-99M-SESTAMIBI; MITOCHONDRIAL;
D O I
10.1371/journal.pone.0109361
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Lipophilic cationic technetium-99m-complexes are widely used for myocardial perfusion imaging (MPI). However, inherent uncertainties in the supply chain of molybdenum-99, the parent isotope required for manufacturing Mo-99/Tc-99m generators, intensifies the need for discovery of novel MPI agents incorporating alternative radionuclides. Recently, germanium/gallium (Ge/Ga) generators capable of producing high quality Ga-68, an isotope with excellent emission characteristics for clinical PET imaging, have emerged. Herein, we report a novel Ga-68-complex identified through mechanism-based cell screening that holds promise as a generator-produced radiopharmaceutical for PET MPI.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] RAPID SEPARATION OF GENERATOR-PRODUCED GALLIUM-68 FROM EDTA ELUATE
    CARLTON, JE
    HAYES, RL
    [J]. INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1971, 22 (01): : 44 - &
  • [2] Gallium-68 Based Positron Emission Tomography (PET) Probes for Myocardial Perfusion Imaging
    Singh, Ajay N.
    Mody, Vicky V.
    Engels, Ingo H.
    Cox, Arthur
    [J]. CURRENT MEDICAL IMAGING, 2015, 11 (03) : 167 - 176
  • [3] PET lung ventilation/perfusion imaging using Gallium-68 aerosol (Galligas) and Gallium-68 labeled macroaggregated albumin (MAA)
    Ament, Stephan
    Maus, Stephan
    Buchholz, Hans
    Reber, Helmut
    Bausbacher, Nicole
    Schreckenberger, Mathias
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [4] Evaluation of the new generator-produced pet radiopharmaceutical Cu62-ETS versus Cu62-PTSM for myocardial perfusion imaging.
    Lacy, JL
    Haynes, NG
    Nayak, N
    Martin, CS
    Dai, D
    Green, MA
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (05) : 171P - 171P
  • [5] A processing method of generator-produced Ga-68 for radiopharmaceutical labeling
    Li, Ming-Hsin
    Chen, Jenn-Tzong
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [6] Gallium-68 PET/CT Ventilation Perfusion Imaging for Acute Pulmonary Embolism
    Hofman, M. S.
    Beauregard, J.
    Barber, T.
    Neels, O. C.
    Eu, P.
    Hicks, R. J.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 : S101 - S102
  • [7] GALLIUM-68 CITRATE PET INFECTION IMAGING
    Schembri, G.
    Kotsiou, G.
    Snowden, G.
    Aslani, A.
    Bailey, E.
    Bailey, D.
    [J]. INTERNAL MEDICINE JOURNAL, 2016, 46 : 21 - 21
  • [8] Regional myocardial perfusion assessed with generator-produced copper-62-PTSM and PET
    Herrero, P
    Hartman, JJ
    Green, MA
    Anderson, CJ
    Welch, MJ
    Markham, J
    Bergmann, SR
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (08) : 1294 - 1300
  • [9] Synthesis of novel gallium-68 labeled rhodamine: A potential PET myocardial perfusion agent
    Al Jammaz, I.
    Al-Otaibi, B.
    Al-Hokbani, N.
    Okarvi, S. M.
    [J]. APPLIED RADIATION AND ISOTOPES, 2019, 144 : 29 - 33
  • [10] Synthesis of Novel Gallium-68 Labeled Rhodamine: a Potential PET Myocardial Perfusion Agent
    Aljammaz, I.
    Alotaibi, B.
    Okarvi, S.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S418 - S418