Correlation of Six Minute Walk Test with Spirometry Indices in Chronic Obstructive Pulmonary Disease Patients

被引:0
|
作者
Priya, Shanmuga K. [1 ]
Prasanth, G. [1 ]
Aarthi, R. [1 ]
Rosheeni, R. [1 ]
Arshad, Abdul Majeed [1 ]
Rajagopalan, B. [1 ]
机构
[1] Sri Ramachandra Inst Higher Educ & Res, Dept Pulm Med, Chennai, Tamil Nadu, India
关键词
Six Minute Walk Test; 6MWT; Spirometry; PFT; COPD;
D O I
10.14260/jemds/2019/812
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Spirometry is the gold standard for accurate measurement of lung function. However, it is only one way of interpreting COPD disease severity and is effort dependent. Measurement of Peak Expiratory Flow Rate, 6-minute walk test (6-MWT) and quantitative assessment of symptoms like MMRC dyspnoea scale offers cheaper modes of assessing lung function. Six Minute Walk Test is the most commonly used test for assessing the functional capacity of persons with Chronic Obstructive Pulmonary Disease. It is a reliable, repeatable, reproducible and responsive test for measuring the functional exercise capacity of patients with Chronic Obstructive Pulmonary Disease. METHODS It is an observational study conducted in South Indian tertiary care hospital. All consecutive patients with confirmed diagnosis of chronic pulmonary disease attending the department of pulmonology, Sri Ramachandra Institute of Higher Education and Research, from January 2018 to January 2019, were included in the study. Six Minute Walk Test and Spirometry were performed as per American Thoracic Society guidelines. Correlation between Six Minute Walk Test and Spirometry was assessed using statistical software, Statistical Package for Social Sciences (SPSS) version 16.0. RESULTS The variables of Six Minute Walk test like six-minute walk distance and six-minute distance saturation both correlated positively with Spirometry parameters FVC, FEV1, FVC/FEV1 in COPD patients. In this study, we demonstrated that six minute walk test significantly correlated with absolute values of Spirometry. Six Minute Walk Test can replace spirometry in assessment of severity of Chronic Obstructive Pulmonary Disease. CONCLUSIONS Six Minute Walk Test significantly correlated with absolute spirometry values of FEV1/FVC, FVC, FEV1. Thus, we conclude that Six Minute Walk Test can replace spirometry in assessment of severity of Chronic Obstructive Pulmonary Disease. The variables of six-minute walk test varied as the severities of the disease varied. The six- minute walk distance and six-minute distance saturation both correlated with Spirometry parameters FVC/FEV1 (moderate positive correlation or weak positive correlation) in severe, very severe Chronic Obstructive Pulmonary Disease patients and SpO2 correlated with the scale. The predicted percent of FVC/FEV1 and FVC correlated with six-minute walk distance saturation in meters.
引用
收藏
页码:3749 / 3753
页数:5
相关论文
共 50 条
  • [1] Correlation between Six Minute Walk Test and Spirometry in Chronic Pulmonary Disease
    Agrawal, Mitali Bharat
    Awad, Nilkanth Tukaram
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2015, 9 (08) : OC1 - OC4
  • [2] Correlation of Sit to Stand Test with Six Minute Walk Test in Chronic Obstructive Pulmonary Disease Patients
    Rehman, Syed Tabish
    Khan, Mateen Ahmed
    Qureshi, Muhammad Azhar
    INTERNATIONAL JOURNAL OF MEDICAL RESEARCH & HEALTH SCIENCES, 2019, 8 (12): : 86 - 91
  • [3] A STUDY ON SIX MINUTE WALK TEST AMONG CHRONIC OBSTRUCTIVE PULMONARY DISEASE PATIENTS
    Dhanasekar, T.
    Ayub, Irfan Ismail
    Pavithra, M.
    Koganti, Sindhura
    Raja, Koushik Muthu
    Arshad, Abdul Majeed
    Rajagopalan, B.
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2016, 5 (41): : 2620 - 2623
  • [4] Association between Six-Minute Walk Test and Expiratory Spirometry Parameters in Chronic Obstructive Pulmonary Disease
    Naghshin, Roozbeh
    Zaker, Mohammad Massood
    Afshar, Amin Ehteshami
    IRANIAN HEART JOURNAL, 2005, 6 (03): : 59 - 63
  • [5] Correlation of six minute walk test with spirometry in COPD patients
    Sarkar, Prajjwal
    Dey, Atin
    Bhattacharya, Somnath
    Chakrabarti, Rohini
    EUROPEAN RESPIRATORY JOURNAL, 2021, 58
  • [6] Stops and its correlation with new measurements during the six-minute walk test in patients with chronic obstructive pulmonary disease
    Preciado, Carlos Andres Celis
    Fernandez, Maria Jose
    Correa, Ximena
    EUROPEAN RESPIRATORY JOURNAL, 2016, 48
  • [7] Correlation of spirometry with six minute walk test and grading of dyspnea
    Patel, Anand
    EUROPEAN RESPIRATORY JOURNAL, 2015, 46
  • [8] Stops During The Six-Minute Walk Test And Its Correlation With New Measurements In Patients With Chronic Obstructive Pulmonary Disease (COPD)
    Fernandez Sanchez, M.
    Celis Preciado, C.
    Correa Rios, X.
    Garcia, O.
    Canas-Arboleda, A.
    Lasso, J.
    Villaquiran-Torres, C.
    Lutz, J.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2016, 193
  • [9] Correlation of Six Minute Walking Test, Sit to Stand Test and Pulmonary Function Test in Patients with Chronic Obstructive Pulmonary Disease
    Premkumar, Kamatchinathan
    Sivagurunathan, Chinnaian
    Ezhilvanan, Mani
    Vikram, Ashokkumar
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2023, 17 (01) : MC9 - VC8
  • [10] Six Minute Walk Distance in Stable Chronic Obstructive Pulmonary Disease
    Gumus, Aziz
    Kayhan, Servet
    Cinarka, Halit
    Yavuz, Asiye
    Yuce, Suleyman
    JOURNAL OF CLINICAL AND ANALYTICAL MEDICINE, 2015, 6 (03) : 274 - 277