Variability in Human Cone Topography Assessed by Adaptive Optics Scanning Laser Ophthalmoscopy

被引:82
|
作者
Zhang, Tianjiao [1 ]
Godara, Pooja [2 ]
Blanco, Ernesto R. [2 ]
Griffin, Russell L. [3 ]
Wang, Xiaolin [2 ]
Curcio, Christine A. [2 ]
Zhang, Yuhua [2 ]
机构
[1] Univ Alabama Birmingham, Dept Biomed Engn, Birmingham, AL 35294 USA
[2] Univ Alabama Birmingham, Dept Ophthalmol, Birmingham, AL 35294 USA
[3] Univ Alabama Birmingham, Dept Epidemiol, Birmingham, AL 35294 USA
关键词
PHOTORECEPTOR PACKING DENSITY; HUMAN FOVEA; IN-VIVO; VISUAL RESOLUTION; HUMAN RETINA; EYE; RELIABILITY; VISION; LIMIT; AGE;
D O I
10.1016/j.ajo.2015.04.034
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To assess between- and within-individual variability of macular cone topography in the eyes of young adults. DESIGN: Observational case series. METHODS: Cone photoreceptors in 40 eyes of 20 subjects aged 19-29 years with normal maculae were imaged using a research adaptive optics scanning laser ophthalmoscope. Refractive errors ranged from - 3.0 diopters (D) to 0.63 D and differed by < 0.50 D in fellow eyes. Cone density was assessed on a 2-dimensional sampling grid over the central 2.4 mm x 2.4 mm. Between-individual variability was evaluated by coefficient of variation (COV). Within-individual variability was quantified by maximum difference and root mean square (RMS). Cones were cumulated over increasing eccentricity. RESULTS: Peak densities of foveal cones are 168 162 +/- 23 529 cones/mm(2) (mean +/- SD) (COV = 0.14). The number of cones within the cone-dominated foveola (0.8-0.9 mm diameter) is 38 311 +/- 2319 (COV = 0.06). The RMS cone density difference between fellow eyes is 6.78%, and the maximum difference is 23.6%. Mixed-model statistical analysis found no difference in the association between eccentricity and cone density in the superior/nasal (P = .8503), superior/temporal (P = .1551), inferior/nasal (P = .8609), and inferior/temporal (P = .6662) quadrants of fellow eyes. CONCLUSIONS: New instrumentation imaged the smallest foveal cones, thus allowing accurate assignment of foveal centers and assessment of variability in macular cone density in a large sample of eyes. Though cone densities vary significantly in the fovea, the total numbers of foveolar cones are very similar both between and within subjects. Thus, the total number of foveolar cones may be an important measure of cone degeneration and loss. ((C) 2015 by Elsevier Inc. All rights reserved.)
引用
收藏
页码:290 / 300
页数:11
相关论文
共 50 条
  • [1] Variability in human cone topography enabled by adaptive optics scanning laser ophthalmoscopy (AOSLO) imaging of foveal centers
    Zhang, Tianjiao
    Curcio, Christine A.
    Zhang, Yuhua
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [2] In situ Densitometry of Cone Photoreceptors in Human Eyes by Adaptive Optics Scanning Laser Ophthalmoscopy
    Hirota, Masakazu
    Miyagawa, Suguru
    Kanda, Hiroyuki
    Endo, Takao
    Lohmann, Tibor Karl
    Morimoto, Takeshi
    Fujikado, Takashi
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [3] Adaptive optics scanning laser ophthalmoscopy
    Roorda, A
    Romero-Borja, F
    Donnelly, WJ
    Queener, H
    Hebert, TJ
    Campbell, MCW
    OPTICS EXPRESS, 2002, 10 (09): : 405 - 412
  • [4] Modeling the foveal cone mosaic imaged with adaptive optics scanning laser ophthalmoscopy
    Putnam, Nicole M.
    Hammer, Daniel X.
    Zhang, Yuhua
    Merino, David
    Roorda, Austin
    OPTICS EXPRESS, 2010, 18 (24): : 24902 - 24916
  • [5] Cone Integrity in Glaucoma: An Adaptive-Optics Scanning Laser Ophthalmoscopy Study
    Hasegawa, Tomoko
    Ooto, Sotaro
    Takayama, Kohei
    Makiyama, Yukiko
    Akagi, Tadamichi
    Ikeda, Hanako O.
    Nakanishi, Hideo
    Suda, Kenji
    Yamada, Hiroshi
    Uji, Akihito
    Yoshimura, Nagahisa
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2016, 171 : 53 - 66
  • [6] Changes in Cone Reflectivity and Regularity Assessed by Adaptive Optics Scanning Laser Ophthalmoscopy (AOSLO) Correlate with Presence of Diabetic Retinopathy
    Lammer, Jan
    Ahmed, Amel
    Prager, Sonja
    Cheney, Michael
    Burns, Stephen
    Silva, Paolo
    Aiello, Lloyd
    Sun, Jennifer
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [7] Intergrader agreement of foveal cone topography measured using adaptive optics scanning light ophthalmoscopy
    Wynne, Niamh
    Cava, Jenna A.
    Gaffney, Mina
    Heitkotter, Heather
    Scheidt, Abigail
    Reiniger, Jenny L.
    Grieshop, Jenna
    Yang, Kai
    Harmening, Wolf M.
    Cooper, Robert F.
    Carroll, Joseph
    BIOMEDICAL OPTICS EXPRESS, 2022, 13 (08) : 4445 - 4454
  • [8] Applications of Adaptive Optics Scanning Laser Ophthalmoscopy
    Roorda, Austin
    OPTOMETRY AND VISION SCIENCE, 2010, 87 (04) : 260 - 268
  • [9] Adaptive optics scanning laser ophthalmoscopy of the human iridocorneal angle in vivo
    King, Brett
    Gast, Thomas
    Sapoznik, Kaitlyn
    Luo, Ting
    Burns, Stephen A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [10] Comparison of adaptive optics scanning laser ophthalmoscopy and high-magnification scanning laser ophthalmoscopy
    Bartsch, Dirk-Uwe
    Jhingan, Mahima
    Zawaydeh, Qais
    Cordeiro, Melina
    Freeman, William
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2021, 62 (08)