Absence of lymphatics at the bone-implant interface - Implications for periprosthetic osteolysis

被引:13
|
作者
Edwards, James [1 ]
Schulze, Eva [1 ]
Sabokbar, Afsie [1 ]
Gordon-Andrews, Helen [1 ]
Jackson, David [2 ]
Athanasou, Nicholas Anthony [1 ]
机构
[1] Univ Oxford, Nuffield Dept Orthopaed Surg, Dept Pathol, Nuffield Orthopaed Ctr, Headington, England
[2] Univ Oxford, John Radcliffe Hosp, Inst Mol Med, Oxford OX3 9DU, England
基金
英国医学研究理事会;
关键词
D O I
10.1080/17453670710015175
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Wear particles, found at the bone-implant interface surrounding a loose prosthesis, are commonly phagocytosed by macrophages. Wear particles and wear particle-containing macrophages are also found in regional lymph nodes draining arthroplasty tissues. The means by which wear particles are transported from arthroplasty tissues to lymph nodes is uncertain, as the presence or absence of lymphatic vessels in periprosthetic tissues has not been established. Methods We determined immunophenotypic expression of LYVE-I and podoplanin, two highly specific lymphatic endothelial cell markers, in the hip arthroplasty pseudocapsule surrounding the false joint and the bone-implant interface of the femoral and acetabular pseudomembrane. Results LYVE-1+/podoplanin+ lymphatic vessels were not identified in the pseudomembrane but were found in the pseudocapsule. Normal bone did not contain lymphatic vessels. Interpretation Our findings suggest that the wear particles shed at the bone-implant interface are not transported to draining lymph nodes by lymphatics directly from the pseudomembrane, but via the pseudocapsule. The absence of a lymphatic clearance mechanism may contribute to accumulation of wear particles at the bone-implant interface and promote periprosthetic osteolysis through stimulation of osteoclast formation and activity.
引用
收藏
页码:289 / 294
页数:6
相关论文
共 50 条
  • [1] Elastography of the bone-implant interface
    Heriveaux, Yoann
    Vu-Hieu Nguyen
    Geiger, Didier
    Haiat, Guillaume
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [2] Elastography of the bone-implant interface
    Yoann Hériveaux
    Vu-Hieu Nguyen
    Didier Geiger
    Guillaume Haïat
    Scientific Reports, 9
  • [3] Strontium in the Bone-Implant Interface
    Vestermark, Marianne Toft
    DANISH MEDICAL BULLETIN, 2011, 58 (05)
  • [4] Engineering the Bone-Implant Interface
    Mangano, Francesco
    Maghaireh, Hassan
    Calvo-Guirado, Jose
    BIOMED RESEARCH INTERNATIONAL, 2018, 2018
  • [5] BONE-IMPLANT INTERFACE CHARACTERISTICS
    ALBREKTSSON, T
    ALBREKTSSON, B
    ACTA ORTHOPAEDICA SCANDINAVICA, 1987, 58 (06): : 715 - 717
  • [6] Proteoglycans at the bone-implant interface
    Klinger, MM
    Rahemtulla, F
    Prince, CW
    Lucas, LC
    Lemons, JE
    CRITICAL REVIEWS IN ORAL BIOLOGY & MEDICINE, 1998, 9 (04) : 449 - 463
  • [7] The bone-implant interface: A dynamic surface
    Goldberg, VM
    Jinno, T
    JOURNAL OF LONG-TERM EFFECTS OF MEDICAL IMPLANTS, 1999, 9 (1-2) : 11 - 21
  • [8] Understanding and controlling the bone-implant interface
    Puleo, DA
    Nanci, A
    BIOMATERIALS, 1999, 20 (23-24) : 2311 - 2321
  • [9] Multiscale Analyses of the Bone-implant Interface
    Cha, J. Y.
    Pereira, M. D.
    Smith, A. A.
    Houschyar, K. S.
    Yin, X.
    Mouraret, S.
    Brunski, J. B.
    Helms, J. A.
    JOURNAL OF DENTAL RESEARCH, 2015, 94 (03) : 482 - 490
  • [10] Stress shielding at the bone-implant interface: Influence of surface roughness and of the bone-implant contact ratio
    Raffa, Maria Letizia
    Nguyen, Vu-Hieu
    Hernigou, Philippe
    Flouzat-Lachaniette, Charles-Henri
    Haiat, Guillaume
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2021, 39 (06) : 1174 - 1183