Experimental Study on Combustion Characteristics and NOx Emissions of Pulverized Anthracite Preheated by Circulating Fluidized Bed

被引:28
|
作者
Wang Jun [1 ,2 ]
Zhu Jian-guo [1 ]
Lu Qing-gang [1 ]
机构
[1] Chinese Acad Sci, Inst Engn Thermophys, Beijing 100190, Peoples R China
[2] Chinese Acad Sci, Graduated Univ, Beijing 100049, Peoples R China
基金
中国国家自然科学基金;
关键词
circulating fluidized bed; preheat; pulverized anthracite; NOx; COAL COMBUSTION; AIR; TEMPERATURE;
D O I
10.1007/s11630-011-0481-6
中图分类号
O414.1 [热力学];
学科分类号
摘要
A 30 kW bench-scale rig of pulverized anthracite combustion preheated by a circulating fluidized bed (CFB) was developed. The CFB riser has a diameter of 90 mm and a height of 1,500 mm. The down-fired combustion chamber (DFCC) has a diameter of 260 mm and a height of 3,000 mm. Combustion experiments were carried out using pulverized anthracite with 6.74% volatile content. This low volatile coal is difficult to ignite and burn out. Therefore, it requires longer burnout time and higher combustion temperature, which results in larger NOx emissions. In the current study, important factors that influence the combustion characteristics and NOx emissions were investigated such as excess air ratio, air ratio in the reducing zone, and fuel residence time in the reducing zone. Pulverized anthracite can be quickly preheated up to 800 degrees C in CFB when the primary air is 24% of theoretical air for combustion, and the temperature profile is uniform in DFCC. The combustion efficiency is 94.2%, which is competitive with other anthracite combustion technologies. When the excess air ratio ranges from 1.26 to 1.67, the coal-N conversion ratio is less than 32% and the NOx emission concentration is less than 371 mg/m(3) (@6% O-2). When the air ratio in the reducing zone is 0.12, the NOx concentration is 221 mg/m(3) (@6% O-2), and the coal-N conversion ratio is 21%, which is much lower than that of other boilers.
引用
收藏
页码:355 / 361
页数:7
相关论文
共 50 条