Retinal and Corneal Changes Associated with Intraocular Silicone Oil Tamponade

被引:26
|
作者
Ferrara, Mariantonia [1 ]
Coco, Giulia [2 ,3 ]
Sorrentino, Tania [4 ]
Jasani, Kirti M. [1 ]
Moussa, George [1 ]
Morescalchi, Francesco [5 ,6 ]
Dhawahir-Scala, Felipe [1 ]
Semeraro, Francesco [5 ,6 ]
Steel, David H. W. [7 ,8 ]
Romano, Vito [5 ,6 ]
Romano, Mario R. [4 ,9 ]
机构
[1] Manchester Royal Eye Hosp, Oxford Rd, Manchester M13 9WL, Lancs, England
[2] Univ Roma Tor Vergata, Dept Clin Sci & Translat Med, I-00133 Rome, Italy
[3] Royal Liverpool Univ Hosp, Dept Corneal Dis, St Pauls Eye Unit, Liverpool L7 8XP, Merseyside, England
[4] Humanitas Univ, Dept Biomed Sci, I-20090 Pieve Emanuele, Italy
[5] Univ Brescia, Dept Med & Surg Specialties, Radiol Sci & Publ Hlth, Eye Clin, I-25121 Brescia, Italy
[6] ASST Civil Hosp Brescia, I-25123 Brescia, Italy
[7] Newcastle Univ, Biosci Inst, Catherine Cookson Bldg, Newcastle Upon Tyne NE2 4HH, Tyne & Wear, England
[8] Sunderland Eye Infirm, Queen Alexandra Rd, Sunderland SR2 9HP, England
[9] Humanitas Gavazzeni Castelli, Eye Ctr, I-24128 Bergamo, Italy
关键词
confocal microscopy; cornea; corneal endothelial cell count; optical coherence tomography; pars plana vitrectomy; retina; retinal layer segmentation; silicone oil; silicone oil emulsification; silicone oil-induced keratopathy; OPTICAL COHERENCE TOMOGRAPHY; NERVE-FIBER-LAYER; PARS-PLANA VITRECTOMY; UNEXPLAINED VISUAL-LOSS; ENDOTHELIAL-CELL DENSITY; DETACHMENT REPAIR; PERFLUOROCARBON LIQUIDS; PROLIFERATIVE VITREORETINOPATHY; MACULAR MICROSTRUCTURE; CONFOCAL MICROSCOPY;
D O I
10.3390/jcm11175234
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Silicone oils (SO) are used as long-term intraocular tamponades and have an irreplaceable role in vitreoretinal surgery. They can, however, be associated with multiple and potentially severe complications, involving different ocular tissues, in particular retina and cornea. Recent advances in ophthalmic imaging have allowed the precise characterization of retinal and corneal microstructural changes, at a subclinical level. This detailed analysis of SO-related retinal and corneal changes has improved our understanding of their pathogenesis and offer the potential for optimized monitoring and management of patients with SO-filled eyes. This review aims to provide clinicians and ophthalmic scientists with an updated and comprehensive overview of the corneal and retinal changes associated with SO tamponade.
引用
收藏
页数:24
相关论文
共 50 条
  • [1] Intraocular silicone oil tamponade in rhegmatogenous retinal detachment
    Eibenberger, Katharina
    Sacu, Stefan
    Rezar-Dreindl, Sandra
    Schmidt-Erfurth, Ursula
    Georgopooulos, Michael
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [2] Migration of silicone oil into the brain: A complication of intraocular silicone oil for retinal tamponade
    Eller, AW
    Friberg, TR
    Mah, F
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2000, 129 (05) : 685 - 688
  • [3] Acute Central Retinal Artery Occlusion Associated with Intraocular Silicone Oil Tamponade
    Teke, Mehmet Yasin
    Elgin, Ufuk
    Ozdal, Pinar
    Ozturk, Faruk
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2012, 42 (03): : 238 - 240
  • [4] Retinal redetachment after removal of intraocular silicone oil tamponade
    Jonas, JB
    Knorr, HLJ
    Rank, RM
    Budde, WM
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2001, 85 (10) : 1203 - 1207
  • [5] Retinal Nerve Fiber Layer Changes after Intraocular Silicone Oil Tamponade in Rhegmatogenous Retinal Detachment
    Chikmah, Fitri Annur
    Ichsan, Andi Muhammad
    Islam, Itzar Chaidir
    Hendarto, Joko
    Muhiddin, Habibah Setyawati
    Budu
    VISION, 2023, 7 (01)
  • [6] 1000 cSt silicone oil vs heavy silicone oil as intraocular tamponade in retinal detachment associated to myopic macular hole
    Mete, Maurizio
    Parolini, Barbara
    Maggio, Emilia
    Pertile, Grazia
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2011, 249 (06) : 821 - 826
  • [7] CHANGES IN CORNEAL ENDOTHELIUM AFTER TREATMENT OF RETINAL-DETACHMENT WITH INTRAOCULAR SILICONE OIL
    SETALA, K
    RUUSUVAARA, P
    PUNNONEN, E
    LAATIKAINEN, L
    ACTA OPHTHALMOLOGICA, 1989, 67 (01): : 37 - 43
  • [8] 1000 cSt silicone oil vs heavy silicone oil as intraocular tamponade in retinal detachment associated to myopic macular hole
    Maurizio Mete
    Barbara Parolini
    Emilia Maggio
    Grazia Pertile
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2011, 249 : 821 - 826
  • [9] Unexplained Vision Loss Associated With Intraocular Silicone Oil Tamponade in Rhegmatogenous Retinal Detachment Repair
    Pakravan, Parastou
    Shaheen, Abdulla
    Patel, Veshesh
    Villalba, Maria F. F.
    Dib, Bernard
    Lai, James
    Rohowetz, Landon
    Chau, Viet
    Patel, Nimesh A. A.
    Tzu, Jonathan H. H.
    Wang, Angeline L. L.
    Alhoyek, Sandra
    Scott, Nathan
    Samara, Wasim A. A.
    Goduni, Lediana
    Jung, Jesse J. J.
    Russell, Jonathan F. F.
    Mantopoulos, Dimosthenis
    Hajrasouliha, Amir R. R.
    Savoie, Brian T. T.
    Haddock, Luis J. J.
    Berrocal, Audina M. M.
    Sridhar, Jayanth
    West, Matthew R. R.
    Yannuzzi, Nicolas A. A.
    JOURNAL OF VITREORETINAL DISEASES, 2023, 7 (04) : 299 - 304
  • [10] Corneal endothelial changes induced by pars plana vitrectomy with silicone oil tamponade for retinal detachment
    Coman , Corina Cristina
    Malita, Daniel
    Stanca, Simona
    Patoni , Stella Ioana
    Musat, Ovidiu
    Negru, Serban
    Feier, Horea
    Karancsi, Olimpiu Ladislau
    Rosca, Cosmin
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2021, 22 (03)