Heat flux profile of the furnace wall of a 300 MWe CFB boiler

被引:27
|
作者
Zhang Man [1 ]
Bie Rushan [1 ]
Yu Zezhong [2 ]
Jiang Xiaoguo [2 ]
机构
[1] Harbin Inst Technol, Sch Energy Sci & Engn, Harbin 150006, Peoples R China
[2] Harbin Boiler Co Ltd, Harbin, Peoples R China
关键词
CFB boiler; Heat transfer; Heat flux; Suspension solid density; Temperature; CIRCULATING FLUIDIZED-BED;
D O I
10.1016/j.powtec.2010.06.021
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
It is important to properly understand and calculate the distributions of the heat flux and the heat transfer coefficient in a furnace for designing a circulating fluidized bed (CFB) boiler, especially for one with supercritical parameters. An experimental study of the heat transfer in a commercial 300 MWe CFB boiler was conducted in this work. The heat flux from the bed to the waterwall was measured by a heat flux meter at four different heights. The influence of suspension density and bed temperature was analyzed by measuring the pressure profile and temperature profile in the furnace. In addition a numerical modeling study on the two phase flow in the furnace was carried out. The results indicate that the density of the solids suspension was non-uniform in the cross section at a certain height, and decreased gradually with increasing furnace height. Consequently, the distribution of heat flux in the horizontal plane was non-uniform and decreased along the height of the furnace. The heat flux showed a decreasing trend near the center. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:548 / 554
页数:7
相关论文
共 50 条
  • [1] The Heat Transfer Coefficients of the Heating Surface of 300 MWe CFB Boiler
    WU Haibo1
    2. Graduate University of Chinese Academy of Sciences
    Journal of Thermal Science, 2012, 21 (04) : 368 - 376
  • [2] The heat transfer coefficients of the heating surface of 300 MWe CFB boiler
    Haibo Wu
    Man Zhang
    Qinggang Lu
    Yunkai Sun
    Journal of Thermal Science, 2012, 21 : 368 - 376
  • [3] The Heat Transfer Coefficients of the Heating Surface of 300 MWe CFB Boiler
    Wu Haibo
    Zhang Man
    Lu Qinggang
    Sun Yunkai
    JOURNAL OF THERMAL SCIENCE, 2012, 21 (04) : 368 - 376
  • [4] Heat transfer measurements inside the furnace of a 135MWe CFB boiler
    Zhang, H
    Lu, JF
    Yang, HR
    Yang, JH
    Wang, Y
    Xiao, XB
    Zhao, XM
    Yue, GX
    Circulating Fluidized Bed Technology VIII, 2005, : 254 - 260
  • [5] Experimental investigation and model validation of the heat flux profile in a 300 MW CFB boiler
    Zhang, Ruiqing
    Yang, Hairui
    Hu, Nan
    Lu, Junfu
    Wu, Yuxin
    POWDER TECHNOLOGY, 2013, 246 : 31 - 40
  • [6] Investigation on the operating characteristics of a 350 MWe supercritical CFB boiler with a polygonal furnace
    Song, Guoliang
    Yang, Zhao
    Na, Yongjie
    Lyu, Qinggang
    Zhou, Qi
    APPLIED THERMAL ENGINEERING, 2019, 156 : 178 - 188
  • [7] Investigation of heat transfer characteristics and optimization design of platen superheaters in the furnace of a 350 MWe supercritical CFB boiler
    Yang, Zhao
    Song, Guoliang
    Cai, Jun
    Zhu, Zhiping
    Applied Thermal Engineering, 2025, 258
  • [8] DeNOx Technology Selection and Optimal Design of SNCR System for a 300MWe CFB Boiler
    Huang Weigang
    Li Jingji
    Yang Hairui
    POWER AND ENERGY SYSTEMS III, 2014, 492 : 7 - +
  • [9] DETERMINATION OF BOILER FURNACE HEAT-FLUX
    RAJARAM, S
    ABRAHAM, KU
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1984, 27 (11) : 2161 - 2166
  • [10] DETERMINATION OF BOILER FURNACE HEAT FLUX.
    Rajaram, S.
    Abraham, K.U.
    International Journal of Heat and Mass Transfer, 1984, 27 (11): : 2161 - 2166