Convection-enhanced high-flux hemodialysis

被引:14
|
作者
Lee, Kyungsoo
Jeong, Jae Hoon
Mun, Cho Hae
Lee, Sa Ram
Yoo, Kyu Jae
Park, Yong Woo
Won, Yong Soon
Min, Byoung Goo
机构
[1] Seoul Natl Univ, Coll Med, Dept Biomed Engn, Seoul 110744, South Korea
[2] Seoul Natl Univ, Interdisciplinary Program Biomed Engn, Seoul 110744, South Korea
[3] Seoul Natl Univ, Inst Med Engn, Med Res Ctr, Seoul 110744, South Korea
[4] Korea Artificial Organ Ctr, Seoul, South Korea
[5] Seoul Natl Univ Hosp, Inst Canc Res, Seoul 110744, South Korea
[6] Soonchunhyang Univ, Dept Thorac & Cardiovasc Surg, Puchon, South Korea
关键词
hemodialysis; hemodiafiltration; internal filtration; convection; backfiltration; hemodialyzer;
D O I
10.1111/j.1525-1594.2007.00436.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Internal filtration contributes to convective clearance in high-flux hemodialysis but its contribution is limited by low pressure gradients. Therefore, a modification using a conventional dialyzer was conceived to enhance internal filtration and backfiltration (BF) rates. The modified dialyzer includes two longitudinal independent regions for blood flow, which were created by redesigning dialyzer caps. Blood pressures remained higher than dialysate pressures in one region and lower in the other region, allowing continuous internal filtration and BF in these respective regions. Modified and conventional dialyzers were compared in terms of pressure gradients and solute clearances. Thus, our experiments involved two groups: the modified dialyzer group and the conventional dialyzer group. A renal failure model was established using a dog weighing 25-30 kg by renal artery and vein ligation. With the exception of the dialyzers, experimental conditions were identical in the two groups. The pressure gradients between blood and dialysate were much higher for the modified dialyzer than for the conventional dialyzer. No significant differences were observed with respect to small solute clearances between the two groups, but mid-range solute clearances were significantly higher in the modified group. More optimization is required before the devised unit can be used clinically. However, the devised unit offers a straightforward means of regulating internal filtration and BF rates.
引用
收藏
页码:653 / 658
页数:7
相关论文
共 50 条
  • [1] Mathematical analysis for internal filtration of convection-enhanced high-flux hemodialyzer
    Lee, Jung Chan
    Lee, Kyungsoo
    Kim, Hee Chan
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2012, 108 (01) : 68 - 79
  • [2] Warning of high-flux hemodialysis
    Takenaka, T
    Kobayashi, K
    Suzuki, H
    RENAL FAILURE, 2001, 23 (06) : 819 - 825
  • [3] A Dual-Chambered Hemodialyzer for Convection-Enhanced Hemodialysis
    Lee, Kyungsoo
    Mun, Cho Hae
    Min, Byoung Goo
    Won, Yong Soon
    ARTIFICIAL ORGANS, 2012, 36 (03) : E78 - E82
  • [4] UREA KINETICS IN HIGH-FLUX HEMODIALYSIS
    PROBST, W
    FIKLOCKI, C
    BINSWANGER, U
    KIDNEY INTERNATIONAL, 1991, 39 (06) : 1329 - 1329
  • [5] VANCOMYCIN PHARMACOKINETICS IN HIGH-FLUX HEMODIALYSIS
    BARTH, RH
    DEVINCENZO, N
    ZARA, AC
    BERLYNE, GM
    CLINICAL RESEARCH, 1990, 38 (02): : A339 - A339
  • [6] HIGH-FLUX (HF) HEMODIALYSIS (HD)
    ACCHIARDO, S
    BURK, L
    BANNISTER, D
    KIDNEY INTERNATIONAL, 1987, 31 (01) : 226 - 226
  • [7] COMPARING UREMIC SOLUTES REMOVAL FOR HIGH-FLUX HEMODIALYSIS, HEMODIAFILTRATION AND HIGH-FLUX HEMODIALYSIS WITH EXERCISE DURING DIALYSIS
    Maheshwari, Vaibhav
    Haroon, Sabrina
    Loy, Yijun
    Samavedham, Lakshminarayanan
    Rangaiah, Gade P.
    Lau, Titus
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2013, 28 : 203 - 203
  • [8] Convection enhanced high flux hemodialysis:: Ex vivo study
    Lee, K
    Jeong, JH
    Mun, CH
    Yoo, KJ
    Park, YW
    Won, YS
    Min, BG
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2006, 29 (05): : 501 - 501
  • [9] High-Flux and Low-Flux Membranes in Hemodialysis
    Oshvandi, Khodayar
    Kavyannejad, Rasol
    Borzuo, Sayed Reza
    Gholyaf, Mahmoud
    NURSING AND MIDWIFERY STUDIES, 2014, 3 (03)
  • [10] Enhanced functional performance characteristics of a new polysulfone membrane for high-flux hemodialysis
    Klingel, R
    Ahrenholz, P
    Schwarting, A
    Röckel, A
    BLOOD PURIFICATION, 2002, 20 (04) : 325 - 333