Numerical test on polystyrene tunnel seismic-isolation material

被引:9
|
作者
He, Jianping [1 ]
Chen, Weizhong [2 ]
Zhao, Wusheng [2 ]
Huang, Sheng [3 ]
Yao, Yunlong [1 ]
机构
[1] Shandong Univ, Weihai 264209, Peoples R China
[2] Chinese Acad Sci, State Key Lab Geomech & Geotech Engn, Inst Rock & Soil Mech, Wuhan 430071, Peoples R China
[3] China Railway Siyuan Survey & Design Grp Co Ltd, Wuhan 430063, Peoples R China
关键词
polystyrene plastic foam; constitutive model; high intensity; tunnel; seismic-isolation layer;
D O I
10.1515/pjct-2016-0058
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
Stress-strain mechanical properties of polystyrene foam plastic material were tested under different loading conditions. An empirical constitutive model for describing metal materials was proposed for the polystyrene plastic foam. The static and dynamic tests results show that the ductility and watertightness of the polystyrene plastic foam are significantly improved. At the same time, in order to check its seismic-isolation property, the high-performance foam concrete as filling materials of Galongla tunnel in Tibet was simulated by FEM. The simulated results show that the polystyrene plastic foam can remarkably decrease the stress and the plastic zone in final lining, so it can effectively reduce the seismic damage of the tunnel. Considering the seismic-isolation property and low price of polystyrene plastic foam, it is a good reference for the anti-seismic design of tunnels in high intensity zones.
引用
收藏
页码:122 / 127
页数:6
相关论文
共 50 条
  • [1] Current State of Seismic-Isolation Design
    Kani, Nagahide
    JOURNAL OF DISASTER RESEARCH, 2009, 4 (03) : 175 - 181
  • [2] Seismic-isolation design of a residence.
    Jin, JM
    Huang, XY
    Zhou, FL
    Luo, XH
    PROCEEDINGS OF THE THIRD INTERNATIONAL CONFERENCE ON EARTHQUAKE ENGINEERING: NEW FRONTIER AND RESEARCH TRANSFORMATION, 2004, : 668 - 671
  • [4] Seismic running safety of trains and a new type of seismic-isolation railway structure
    Luo, Xiu
    TRANSPORTATION SAFETY AND ENVIRONMENT, 2021, 3 (02): : 152 - 165
  • [5] Seismic isolation effect of a tunnel covered with coating material
    Kim, DS
    Konagai, K
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2000, 15 (04) : 437 - 443
  • [6] A New Seismic-Isolation Device Applied in Continuous Beam Bridge
    Yan, Bin
    ADVANCED ENGINEERING MATERIALS, PTS 1-3, 2011, 194-196 : 2008 - 2013
  • [7] Seismic running safety of trains and a new type of seismic-isolation railway structure
    Xiu Luo
    Transportation Safety and Environment, 2021, 3 (02) : 152 - 165
  • [8] Onset of Motion of Curved Surface Sliders Used in Seismic-Isolation Systems
    Ormando, Chiara
    Clemente, Paolo
    Ianniruberto, Ugo
    Scafati, Federico
    PRACTICE PERIODICAL ON STRUCTURAL DESIGN AND CONSTRUCTION, 2021, 26 (03)
  • [9] Comparative analysis on seismic-isolation design methods for ridge frame bridge
    Yan, B.
    Du, X. L.
    BRIDGE MAINTENANCE, SAFETY, MANAGEMENT AND LIFE EXTENSION, 2014, : 2215 - 2220
  • [10] Relaxation Test and Numerical Modeling of Rubber for Seismic Base Isolation
    Habieb, A. B.
    Milani, G.
    Quaglini, V
    Milani, F.
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE OF COMPUTATIONAL METHODS IN SCIENCES AND ENGINEERING 2019 (ICCMSE-2019), 2019, 2186