Measurement of crosstalk between crossing superconductor microstrip lines

被引:12
|
作者
Hashimoto, Y
Yorozu, S
Terai, H
Fujimaki, A
机构
[1] NEC Corp Ltd, Fundamental Res Labs, Tsukuba, Ibaraki 3058501, Japan
[2] Commun Res Labs, Kansai Adv Res Ctr, Kobe, Hyogo 6512492, Japan
[3] Nagoya Univ, Dept Quantum Engn, Chikusa Ku, Nagoya, Aichi 4648603, Japan
关键词
superconducting devices; single flux quantum logic; passive transmission line; crosstalk;
D O I
10.1016/S0921-4534(03)01189-4
中图分类号
O59 [应用物理学];
学科分类号
摘要
We experimentally evaluated the effect of crosstalk between crossing microstrip lines (MSLs) on our MSL receiver. The measurement circuit consisted of two crossing MSLs, referred to as the upper MSL and lower MSL. At the crossing area, the upper MSL and lower MSL were separated by a 400-nm thickness Of SiO2 thin film. The parasitic capacitance between them was estimated to be about 0.1 pF. We measured bias margin of the receiver connected to the lower MSL under two conditions: with a pulse train running through the upper MSL, i.e., with crosstalk noise, and without a pulse train in the upper MSL, i.e., without crosstalk noise. Our measurements showed that (i) crosstalk mainly reduced the lower limit of the receiver's bias margin, and (ii) this reduction of bias margin was enhanced by resonance when the repetition frequency of pulses in the upper ring satisfied resonance condition. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:1472 / 1477
页数:6
相关论文
共 50 条
  • [1] Measurement of crosstalk between crossing superconductor microstrip lines
    Hashimoto, Y. (y-hashimoto@cd.jp.nec.com), 1600, (Elsevier): : 392 - 396
  • [2] CROSSTALK BETWEEN MICROSTRIP TRANSMISSION-LINES
    HILL, DA
    CAVCEY, KH
    JOHNK, RT
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 1994, 36 (04) : 314 - 321
  • [3] High frequency crosstalk between two microstrip lines
    Bernal, J
    Mesa, F
    Rodríguez-Berral, R
    Jackson, DR
    2003 IEEE MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM DIGEST, VOLS 1-3, 2003, : 813 - 816
  • [4] THE MEASUREMENT OF CROSSTALK BETWEEN TRUNK LINES
    VERNIK, SM
    KURSHEV, NV
    NIKITIN, BK
    RUDNITSKIY, VB
    TELECOMMUNICATIONS AND RADIO ENGINEERING, 1983, 37-8 (03) : 43 - 46
  • [5] Characteristics for Crosstalk between Dual Microstrip Transmission Lines in PCB
    Wang, Xin
    Huang, Hui
    Liu, Qi
    PIERS 2011 SUZHOU: PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM, 2011, : 1190 - 1194
  • [6] ANALYSIS AND COMPUTATION OF CROSSTALK NOISE BETWEEN MICROSTRIP TRANSMISSION LINES
    OKUGAWA, S
    HAGIWARA, H
    ELECTRONICS & COMMUNICATIONS IN JAPAN, 1970, 53 (07): : 128 - +
  • [7] Reducing crosstalk between microstrip lines using CSR structure
    Wang, Yafei
    Li, Chenlong
    Li, Xuehua
    ENGINEERING REPORTS, 2024, 6 (03)
  • [8] MEASUREMENT OF CROSSTALK BETWEEN TRUNK LINES.
    Vernik, S.M.
    Kurshev, N.V.
    Nikitin, B.K.
    Rudnitskiy, V.B.
    Telecommunications and Radio Engineering (English translation of Elektrosvyaz and Radiotekhnika), 1983, 37-38 (03): : 43 - 46
  • [9] Crosstalk of microstrip lines with capacitor loads
    Noguchi, Y
    Ohtani, M
    Mariko, K
    Matsumoto, F
    INTERNATIONAL JOURNAL OF ELECTRONICS, 1998, 85 (03) : 327 - 336
  • [10] REDUCING CROSSTALK IN MICROSTRIP LINES.
    Rabbat, N.B.