Prospective comparison of 3-dimensional volume rendered computerized tomography and conventional renal arteriography for surgical planning in patients undergoing laparoscopic donor nephrectomy

被引:54
|
作者
Abou El Fettouh, H
Herts, BR
Nimeh, T
Wirth, SL
Caplin, A
Sands, M
Ramani, AP
Kaouk, J
Goldfarb, DA
Gill, IS
机构
[1] Cleveland Clin Fdn, Inst Urol, Sect Laparoscop & Minimally Invas Surg, Cleveland, OH 44195 USA
[2] Cleveland Clin Fdn, Inst Urol, Sect Renal Transplantat, Cleveland, OH 44195 USA
[3] Cleveland Clin Fdn, Dept Radiol, Cleveland, OH 44195 USA
来源
JOURNAL OF UROLOGY | 2003年 / 170卷 / 01期
关键词
kidney; nephrectomy; tomography; x-ray computed; angiography; laparoscopy;
D O I
10.1097/01.ju.0000068039.79654.d3
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose: We prospectively assessed the accuracy of 3-dimensional (3-D) volume rendered computerized tomography (CT) and conventional renal arteriography to visualize renovascular anatomy in patients undergoing laparoscopic donor nephrectomy. Materials and Methods: A total of 60 consecutive patients undergoing laparoscopic donor nephrectomy (left side in 46 and right side in 14) prospectively underwent 3-D CT and renal angiography. A short videotape of 3-D CT was prepared using volume rendering software that demonstrated the anatomical location, number, anomalies and spatial interrelationships of the renal arteries and veins. These 3-D videotapes and arteriogram findings were directly correlated with intraoperative surgical findings at laparoscopy and during ex vivo bench preparation of the harvested kidney. The perceived intraoperative value of 3D-CT to delineate renovascular anatomical detail was scored subjectively by the laparoscopic surgeon for each case on a 10-point scale of 0-completely inaccurate to 10-completely accurate. Results: There were no complications related to the 3-D CT protocol and volume rendering was successful in all patients. Three-D CT accurately identified the number of renal arteries in 59 patients (98%). In I patient with 3 renal arteries 3-D CT and arteriogram each identified only 2. In the 46 patients undergoing left donor nephrectomy 3-D CT accurately identified the number of veins and venous anomalies in 45 (98%), including 2 with a circumaortic left renal vein. Another case of circumaortic vein was misdiagnosed as 2 renal veins. On the right side in 14 patients 3-D CT accurately identified the renal veins in 13 (94%) and missed 1 vein in a patient with 2 renal veins. Angiography correctly identified the number of renal veins in only 52 cases (87%). Furthermore, it misdiagnosed all 3 cases of circumaortic left renal vein. The laparoscopic surgeon believed that 3-D CT accurately identified the location and anatomical interrelationship of the renal vessels with precision. Mean subjective score +/- SEM was 8.5 +/- 1 for the arterial system, 8.6 +/- 1.1 for the venous system and 9.2 +/- 0.5 for any vascular anomalies. Conclusions: Three-D CT accurately identifies renal vascular anatomy in a manner that may facilitate renal hilar dissection during laparoscopic donor nephrectomy, especially during the initial surgeon experience. This imaging modality integrates essential information from angiography, venography and excretory urography into a single study, and it can obviate the need for more invasive vascular imaging in most cases.
引用
收藏
页码:57 / 60
页数:4
相关论文
共 22 条
  • [1] Prospective comparison of 3-dimensional volume rendered computerized tomography and conventional renal arteriography for surgical planning in patients undergoing laparoscopic donor nephrectomy
    El Fettouh, HIA
    Herts, B
    Nimeh, T
    Wirth, SL
    Caplin, A
    Goldfarb, DA
    Gill, IS
    JOURNAL OF UROLOGY, 2002, 167 (04): : 387 - 388
  • [2] Helical computerized tomography arteriography for evaluation of live renal donors undergoing laparoscopic nephrectomy
    Del Pizzo, JJ
    Sklar, GN
    You-Cheong, JW
    Levin, B
    Krebs, T
    Jacobs, SC
    JOURNAL OF UROLOGY, 1999, 162 (01): : 31 - 34
  • [3] 3-dimensional volume rendered computerized tomography for preoperative evaluation and intraoperative treatment of patients undergoing nephron sparing surgery
    Coll, DM
    Uzzo, RG
    Herts, BR
    Davros, WJ
    Wirth, SL
    Novick, AC
    JOURNAL OF UROLOGY, 1999, 161 (04): : 1097 - 1102
  • [4] Interactive 3-dimensional computerized tomography reconstruction in evaluation of living renal donor
    Lerner, LB
    Henriques, HF
    Harris, RD
    JOURNAL OF UROLOGY, 1999, 161 (02): : 403 - 407
  • [5] Comparison of three dimensional reconstruction and conventional computer tomography angiography in patients undergoing zero-ischemia laparoscopic partial nephrectomy
    Xiaorong Wu
    Chen Jiang
    Guangyu Wu
    Chao Shen
    Qibo Fu
    Yonghui Chen
    Dongming Liu
    Wei Xue
    BMC Medical Imaging, 20
  • [6] Comparison of three dimensional reconstruction and conventional computer tomography angiography in patients undergoing zero-ischemia laparoscopic partial nephrectomy
    Wu, Xiaorong
    Jiang, Chen
    Wu, Guangyu
    Shen, Chao
    Fu, Qibo
    Chen, Yonghui
    Liu, Dongming
    Xue, Wei
    BMC MEDICAL IMAGING, 2020, 20 (01)
  • [7] Computerized tomography with 3-dimensional reconstruction for the evaluation of renal size and arterial anatomy in the living kidney donor
    Janoff, DM
    Davol, P
    Hazzard, J
    Lemmers, MJ
    Paduch, DA
    Barry, JM
    JOURNAL OF UROLOGY, 2004, 171 (01): : 27 - 30
  • [8] PRE-OPERATIVE VIRTUAL LAPAROSCOPIC NEPHRECTOMY USING 3-DIMENSIONAL COMPUTERIZED TOMOGRAPHY - A UROLOGY RESIDENTS TRAINING TOOL
    Watcyn-Jones, Thomas
    Youssef, Fady
    Kamath, Sadashiv
    Pathak, Sanjeev
    JOURNAL OF UROLOGY, 2014, 191 (04): : E66 - E67
  • [9] CT urogram vs. CT angiography with 3-dimensional reconstruction for preoperative planning of laparoscopic donor nephrectomy
    Kristo, B
    Perry, KT
    Phelan, MW
    Schulam, PG
    JOURNAL OF UROLOGY, 2003, 169 (04): : 495 - 495
  • [10] Diagnostic accuracy of a volume-rendered computed tomography movie and other computed tomography-based imaging methods in assessment of renal vascular anatomy for laparoscopic donor nephrectomy
    Yamamoto, Shingo
    Tanooka, Masao
    Ando, Kumiko
    Yamano, Toshiko
    Ishikura, Reiichi
    Nojima, Michio
    Hirota, Shozo
    Shima, Hiroki
    INTERNATIONAL UROLOGY AND NEPHROLOGY, 2009, 41 (04) : 785 - 790