A quantitative comparison of a bone remodeling model with dual-energy X-ray absorptiometry and analysis of the inter-individual biological variability of femoral neck T-score

被引:15
|
作者
Santos, L. [1 ,2 ]
Romeu, J. C. [3 ]
Canhao, H. [2 ,3 ]
Fonseca, J. E. [2 ,3 ]
Fernandes, P. R. [1 ]
机构
[1] Univ Tecn Lisboa, IDMEC IST, P-1100 Lisbon, Portugal
[2] Univ Lisbon, Lisbon Sch Med, Inst Mol Med, Rheumatol Res Unit, P-1699 Lisbon, Portugal
[3] Hosp Santa Maria, Rheumatol & Bone Dis Dept, Lisbon, Portugal
关键词
Osteoporosis; Bone remodeling; DXA; Finite element model; Femoral neck; FINITE-ELEMENT MODELS; PROXIMAL FEMUR; IN-VITRO; HIP FRACTURE; LONG BONES; SIMULATION; DENSITY; STRAIN; RISK; STRENGTH;
D O I
10.1016/j.jbiomech.2010.07.028
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The development of consistent procedures with the inclusion of patient-specific data is essential in the computational modeling of biological processes, in order to achieve clinical relevant data. In this work, these issues are addressed with the development of a methodology that combines the gold standard technique for bone mineral density measurement and osteoporosis diagnosis, Dual energy X-ray absorptiometry (DXA), with a computational model for bone remodeling simulation. The DXA results were divided in three samples constituted from proximal femur DXA exams of patients in different stages of bone mineral density (normal, osteopenia and osteoporosis). These results were quantitatively compared with computational model results. A correlation study was performed between femoral neck T-score and a parameter from the model to ascertain the hypothesis of adjusting the model accordingly to biological variables. The results evidenced the predictive ability of the computational model in the estimation of femoral neck bone mineral content (BMC), with a maximum relative error of 3.92%. On the other hand, a strong correlation (R = -0.862) was found between the variables in study and a mathematical relationship was obtained to estimate the range of values for a model parameter that leads to biological relevant results. The methodology developed and the results obtained represent a solid and reliable basis to further studies on bone quality, ensuring the validity of the computational model in the simulation of bone remodeling process. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3150 / 3155
页数:6
相关论文
共 50 条
  • [1] DUAL-ENERGY X-RAY ABSORPTIOMETRY OF THE CALCANEUS - COMPARISON WITH VERTEBRAL DUAL-ENERGY X-RAY ABSORPTIOMETRY AND QUANTITATIVE COMPUTED-TOMOGRAPHY
    LAVALJEANTET, AM
    BERGOT, C
    WILLIAMS, M
    DAVIDSON, K
    LAVALJEANTET, M
    CALCIFIED TISSUE INTERNATIONAL, 1995, 56 (01) : 14 - 18
  • [2] DUAL-ENERGY X-RAY ABSORPTIOMETRY ANALYSIS OF FEMORAL REMODELING OBSERVED WITH UNCEMENTED PROSTHESES OF DIFFERENT DESIGNS
    SCOTT, DF
    JAFFE, F
    JAFFE, W
    JOURNAL OF BONE AND MINERAL RESEARCH, 1993, 8 : S347 - S347
  • [3] DUAL-ENERGY X-RAY ABSORPTIOMETRY AS AN INDICATOR FOR FRAGILITY FRACTURE RISKS OF THE FEMORAL NECK
    Tsouknidas, Alexander
    Michailidis, Nikolaos
    Anagnostidis, Kleovoulos
    Lontos, Antonios
    BIOINFORMATICS: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON BIOINFORMATICS MODELS, METHODS AND ALGORITHMS, 2012, : 96 - 101
  • [4] Evaluation of femoral head bone quality by Hounsfield units: a comparison with dual-energy X-ray absorptiometry
    Kilinc, Rabia Mihriban
    Acan, Ahmet Emrah
    Turk, Gamze
    Kilinc, Cem Yalin
    Yeniceri, Ibrahim Onder
    ACTA RADIOLOGICA, 2022, 63 (07) : 933 - 941
  • [5] Quantitative ultrasound of the radius and calcaneus: a comparison with dual-energy X-ray absorptiometry
    Boyanov, M.
    Shinkov, A.
    Nestorova, R.
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 2007, 132 (16) : 869 - 873
  • [6] Dual-energy X-ray Absorptiometry Does Not Represent Bone Structure in Patients with Osteoporosis A Comparison of Lumbar Dual-Energy X-Ray Absorptiometry with Vertebral Biopsies
    Pumberger, Matthias
    Palmowski, Yannick
    Strube, Patrick
    Schwemmer, Christin
    Roll, Stephanie
    Zippelius, Timo
    Putzier, Michael
    SPINE, 2021, 46 (13) : 861 - 866
  • [7] Maintenance of proximal bone mass with an uncemented femoral stem analysis with dual-energy x-ray absorptiometry
    Wixson, RL
    Stulberg, D
    VanFlandern, GJ
    Puri, L
    JOURNAL OF ARTHROPLASTY, 1997, 12 (04): : 365 - 372
  • [8] Comparison of bone mineral density and T-score measured by two different dual X-ray absorptiometry machines.
    Yang, SO
    Ham, SY
    Jeong, YK
    Lee, JH
    Lee, HK
    JOURNAL OF BONE AND MINERAL RESEARCH, 1999, 14 : S367 - S367
  • [9] Role of dual-energy X-ray absorptiometry in the estimation of the risk for femoral neck fractures in osteoporosis
    Makarov, M. A.
    Rodionova, S. S.
    OSTEOPOROSIS INTERNATIONAL, 2006, 17 : S301 - S302
  • [10] GEOMETRIC STRUCTURE OF THE FEMORAL-NECK MEASURED USING DUAL-ENERGY X-RAY ABSORPTIOMETRY
    YOSHIKAWA, T
    TURNER, CH
    PEACOCK, M
    SLEMENDA, CW
    WEAVER, CM
    TEEGARDEN, D
    MARKWARDT, P
    BURR, DB
    JOURNAL OF BONE AND MINERAL RESEARCH, 1994, 9 (07) : 1053 - 1064