END-TO-END AUDIT: COMPARISON OF TLD AND LITHIUM FORMATE EPR DOSIMETRY

被引:1
|
作者
Adolfsson, Emelie [1 ,2 ]
Wesolowska, Paulina [3 ]
Izewska, Joanna [3 ]
Lund, Eva [2 ]
Tedgren, Asa Carlsson [2 ,4 ]
机构
[1] Linkoping Univ, Dept Radiat Phys, SE-58185 Linkoping, Sweden
[2] Linkoping Univ, Dept Med & Hlth Sci, SE-58185 Linkoping, Sweden
[3] IAEA, Dosimetry & Med Radiat Phys Sect, A-1020 Vienna, Austria
[4] Karolinska Univ Hosp, Dept Med Radiat Phys & Nucl Med, Sect Radiotherapy Phys & Engn, SE-17176 Stockholm, Sweden
关键词
RADIOTHERAPY; SERVICE; SYSTEM;
D O I
10.1093/rpd/ncy289
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The aim of this study was to test two different solid state dosimetry systems for the purpose of end-to-end audits of radiotherapy volumetric modulated arc therapy (VMAT) technique; a lithium formate electron paramagnetic resonance system and a lithium fluoride thermoluminescent dosimetry system. As a complement to the solid state systems, ion chamber measurements were performed. A polystyrene phantom with a planning target volume (PTV) and an organ at risk (OAR) structure was scanned using CT. A VMAT dose plan was optimized to deliver 2 Gy to the target volume and to minimize the dose to the OAR. The different detectors were inserted into the phantom and the planned dose distribution was delivered. The measured doses were compared to the treatment planning system (TPS) calculated doses. Good agreement was found between the TPS calculated and the measured doses, well accepted for the dose determinations in remote dosimetry audits of VMAT treatment technique.
引用
收藏
页码:119 / 122
页数:4
相关论文
共 50 条
  • [1] End-to-end dosimetric audit - comparison of TLD and lithium formate EPR dosimetry
    Adolfsson, E.
    Wesolowska, P.
    Izewska, J.
    Lund, E.
    Olsson, M.
    Tedgren, A. Carlsson
    [J]. RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S917 - S917
  • [2] A national cranial stereotactic radiosurgery end-to-end dosimetry audit
    Dimitriadis, A.
    Thomas, R. A. S.
    Palmer, A. L.
    Eaton, D.
    Lee, J.
    Patel, R.
    Patallo, I. Silvestre
    Nisbet, A.
    Clark, C. H.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S287 - S287
  • [3] Australasian brachytherapy audit: Results of the "end-to-end' dosimetry pilot study
    Haworth, Annette
    Wilfert, Lisa
    Butler, Duncan
    Ebert, Martin A.
    Todd, Stephen
    Bucci, Joseph
    Duchesne, Gillian M.
    Joseph, David
    Kron, Tomas
    [J]. JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2013, 57 (04) : 490 - 498
  • [4] What can reveal onsite end-to-end audit? The experience of national dosimetry audit group
    Koniarova, I.
    Horakova, I.
    Dufek, V.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S951 - S952
  • [5] Pilot study of a remote end-to-end dosimetry audit for IMRT and VMAT treatments
    Wesolowska, P.
    Almady, B.
    Adolfsson, E.
    Tedgren, A. Carlsson
    Georg, D.
    Kry, S.
    Lechner, W.
    Povall, J.
    Tenhunen, M.
    Tomsej, M.
    Izewska, J.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S164 - S165
  • [6] Results from ACDS end-to-end dosimetry audit of spine and lung SBRT
    Lye, J.
    Shaw, M.
    Alves, A.
    Supple, J.
    Davey, C.
    Brown, R.
    Cole, A.
    Kadeer, F.
    Kenny, J.
    Lehmann, J.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2019, 141 : S5 - S6
  • [7] LITHIUM FORMATE EPR DOSIMETRY FOR DOSIMETRY VERIFICATIONS IN RADIOTHERAPY
    Olsson, S.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S27 - S27
  • [8] Adaptation and validation of a commercial head phantom for cranial radiosurgery dosimetry end-to-end audit
    Dimitriadis, Alexis
    Palmer, Antony L.
    Thomas, Russell A. S.
    Nisbet, Andrew
    Clark, Catharine H.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2017, 90 (1074):
  • [9] A CT Polymer Gel Dosimetry System for End-To-End Dosimetry
    Hilts, M.
    Carrick, J.
    Johnston, H.
    Jirasek, A.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [10] 3D Dosimetry in End-To-End Dosimetry QA
    Ibbott, G.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3695 - 3695