Effects of contact angle hysteresis on bubble dynamics and heat transfer characteristics in saturated pool boiling

被引:15
|
作者
Wang, Haoyuan
Lou, Qin [1 ]
Liu, Gaojie
Li, Ling
机构
[1] Univ Shanghai Sci & Technol, Sch Energy & Power Engn, Shanghai 200093, Peoples R China
基金
上海市自然科学基金; 中国国家自然科学基金;
关键词
Boiling heat transfer; Contact angle hysteresis; Boiling curves; Bubble dynamics; Lattice Boltzmann method; LATTICE BOLTZMANN SIMULATIONS; NUMERICAL-SIMULATION; DEPARTURE DIAMETER; FLOW; SURFACE; WETTABILITY; EQUATION; GROWTH; LBM; RELEASE;
D O I
10.1016/j.ijthermalsci.2022.107554
中图分类号
O414.1 [热力学];
学科分类号
摘要
As an inherent physical phenomenon of the contact-line motion, the contact angle hysteresis (CAH) has an important effect on dynamic behaviors of bubble/bubbles from a solid surface. In this study, boiling heat transfer considering the CAH is investigated by employing a phase change lattice Boltzmann (LB) model. Effects of the CAH on the bubble/bubbles dynamics during the boiling process and the boiling curves for both the hydrophilic and hydrophobic hysteresis windows are studied in detail. It is found that the bubble base, bubble height and phase change rate increase as the increase of the width of hysteresis window. On the other hand, the pinning of three-phase contact line is observed during the bubble growth processes. And the pinning times increase with the contact angle hysteresis. For the hydrophilic hysteresis window, the bubble completely departs from the heater if a small range of the hysteresis window is considered, while a residual bubble is left when the bubble departs from the heater in the cases of the hysteresis window larger than an approximate critical value of 45 degrees. For the hydrophobic hysteresis window, a residual bubble can be observed regardless of the level of the contact angle hysteresis. The numerical results also indicate that the CAH affects the position of bubbles coalescence. The bubbles merge above the heater for the hydrophilic hysteresis window with a small level of hysteresis. While the bubbles merge on the heater for the hydrophilic hysteresis window with a large level of hysteresis as well as for the hydrophobic hysteresis window. Moreover, as the increase of the width of the hysteresis window, the critical heat flux (CHF) as well as the Leidenfrost temperature (the minimum temperature for film boiling) decrease, and the transition boiling regimes become shorter. Finally, we present the fitting equations between the width of the hysteresis window and the CHF/Leidenfrost temperature. The results show that the CHF and the Leidenfrost temperature decrease linearly as the width of the hysteresis window increases.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Vapor bubble dynamics and heat transfer characteristics over the spherical surface during saturated pool boiling
    Kushwaha, Naveen
    Sasmito, Agus P.
    Kumar, Vimal
    HEAT TRANSFER, 2023, 52 (01) : 1000 - 1028
  • [2] Bubble Dynamics and Heat Transfer in Microgravity Pool Boiling
    Zhao, Jian-Fu
    ADVANCED RESEARCH IN PHYSICS AND ENGINEERING, 2010, : 54 - +
  • [3] Experimental investigation on bubble dynamics and boiling heat transfer for saturated pool boiling and comparison data with previous works
    Chang, Y. H.
    Ferng, Y. M.
    APPLIED THERMAL ENGINEERING, 2019, 154 : 284 - 293
  • [4] Bubble dynamics and heat transfer during pool and flow boiling
    Dhir, Vijay K.
    Abarajith, Hari S.
    Li, Ding
    HEAT TRANSFER ENGINEERING, 2007, 28 (07) : 608 - 624
  • [5] HYSTERESIS AND CONTACT-ANGLE EFFECTS IN TRANSITION POOL BOILING OF WATER
    MARACY, M
    WINTERTON, RHS
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1988, 31 (07) : 1443 - 1449
  • [6] Experimental Study of Bubble Dynamics in Pool Boiling Heat Transfer using Saturated Water and Surfactant solution
    Najim, A.
    Acharya, A. R.
    Pise, A. T.
    Gajghate, S. S.
    2014 INTERNATIONAL CONFERENCE ON ADVANCES IN ENGINEERING AND TECHNOLOGY (ICAET), 2014,
  • [7] Bubble Dynamics and Heat Transfer in Pool Boiling on Wires at Different Gravity
    Zhao, Jian-Fu
    Wan ', Shi-Xin
    ASTM Special Technical Publication, 2012, 1534 : 402 - 419
  • [8] Bubble dynamics and heat transfer in pool boiling on wires at different gravity
    Zhao J.-F.
    Wan S.-X.
    Journal of ASTM International, 2011, 8 (05):
  • [9] Bubble dynamics and heat transfer under a single bubble during nucleate pool boiling
    Bi, Jing-Liang
    Christopher, David M
    Lin, Xi-Peng