Retinometer predicts visual outcome in Descemet membrane endothelial keratoplasty

被引:1
|
作者
Wald, Caroline Sophie [1 ]
Unterlauft, Jan Darius [2 ]
Rehak, Matus [3 ]
Girbardt, Christian [1 ]
机构
[1] Univ Leipzig, Dept Ophthalmol, Med Ctr, Liebigstr 10-14, D-04103 Leipzig, Germany
[2] Univ Bern, Univ Dept Ophthalmol, Inselspital, Bern, Switzerland
[3] Univ Hosp Giessen & Marburg, Dept Ophthalmol, Giessen, Germany
关键词
Retinometer; DMEK; Corneal transplantation; Interference visual acuity; POTENTIAL ACUITY METER; CATARACT; TRANSPLANTATION; SURGERY;
D O I
10.1007/s00417-022-05605-w
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To analyze the preoperative predictive value of retinometer visual acuity (VA) in eyes following Descemet membrane endothelial keratoplasty (DMEK). Methods Patients undergoing DMEK between August 2011 and July 2020 were included. Preoperative interference visual acuity was assessed using Heine Lambda 100 Retinometer. Depending on the presence or absence of concomitant ocular disease, the Retinometer was evaluated for its ability to preoperatively predict best-corrected visual acuity (BCVA) six months after surgery using correlation, simple and multiple linear regression, contingency analyses, and receiver operating characteristic (ROC) analysis. Preoperative corneal backscatter was correlated with Retinometer prediction accuracy. Results A total of 198 eyes were included in the analysis. There was a significant correlation between Retinometer VA and postoperative BCVA (r = 0.647, P < 0.001). Regardless of the presence or absence of concomitant ocular disease and the surgery procedure (DMEK & triple DMEK), Retinometer VA was the most significant predictor of postoperative BCVA (P < 0.001). ROC analysis revealed reliable diagnostic performance of the Retinometer (AUC = 0.829, P < 0.001). A Retinometer VA >= 0.5 accurately predicted a postoperative BCVA >= 0.5 in 91% of cases. No association was found between corneal backscatter and prediction accuracy (P = 0.566). Conclusions Retinometer VA can be used for preoperative prediction of postoperative BCVA in DMEK and triple DMEK patients, independent of increased backscatter values and the presence or absence of concomitant ocular disease. By using this simple but effective tool, indication for DMEK can be facilitated and postoperative outcomes can be realistically predicted preoperatively.
引用
收藏
页码:2283 / 2290
页数:8
相关论文
共 50 条
  • [1] Retinometer predicts visual outcome in Descemet membrane endothelial keratoplasty
    Caroline Sophie Wald
    Jan Darius Unterlauft
    Matus Rehak
    Christian Girbardt
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2022, 260 : 2283 - 2290
  • [2] Visual outcome of penetrating keratoplasty, deep anterior lamellar keratoplasty and Descemet membrane endothelial keratoplasty
    Garrido, Claudia
    Cardona, Genis
    Guell, Josep L.
    Pujol, Jaume
    JOURNAL OF OPTOMETRY, 2018, 11 (03) : 174 - 181
  • [3] Impact of preoperative visual acuity on Descemet Membrane Endothelial Keratoplasty (DMEK) outcome
    Schrittenlocher, Silvia
    Bachmann, B.
    Tiurbe, A. M.
    Tuac, O.
    Velten, K.
    Schmidt, D.
    Cursiefen, C.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2019, 257 (02) : 321 - 329
  • [4] Impact of preoperative visual acuity on Descemet Membrane Endothelial Keratoplasty (DMEK) outcome
    Silvia Schrittenlocher
    B. Bachmann
    A. M. Tiurbe
    O. Tuac
    K. Velten
    D. Schmidt
    C. Cursiefen
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2019, 257 : 321 - 329
  • [5] Mediators of Visual Acuity in Descemet Membrane Endothelial Keratoplasty and Ultrathin Descemet Stripping Automated Endothelial Keratoplasty
    Lin, Charles C.
    Chamberlain, Winston D.
    Kakigi, Caitlin
    Arnold, Benjamin F.
    Rose-Nussbaumer, Jennifer
    CORNEA, 2024, 43 (07) : 853 - 859
  • [6] Outcome of Descemet membrane endothelial keratoplasty for graft failure after Descemet stripping automated endothelial keratoplasty
    Agha, Bishr
    Shajari, Mehdi
    Slavik-Lencova, Anna
    Kohnen, Thomas
    Schmack, Ingo
    CLINICAL OPHTHALMOLOGY, 2019, 13 : 553 - 559
  • [7] The influence of ocular surface parameters on the visual outcome of Descemet-membrane endothelial keratoplasty
    Spaniol, Kristina
    Schwinde, Jan Hendrik
    Hoffmann, Marianne
    Borrelli, Marianne
    Schrader, Stefan
    Geerling, Gerd
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [8] Where is endothelial keratoplasty going: from Descemet stripping (automated) endothelial keratoplasty to Descemet membrane endothelial keratoplasty to Descemet membrane endothelial transfer?
    Tong, C. Maya
    Melles, Gerrit R. J.
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2012, 47 (03): : 197 - 199
  • [9] Descemet Membrane Endothelial Keratoplasty
    Luft, N.
    Dirisamer, M.
    Priglinger, S.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2017, 234 (03) : 354 - 364
  • [10] Descemet membrane endothelial keratoplasty
    Xuan, Rachel
    Hong, Sheng Chiong
    Trinh, Tanya
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2023, 51 (09): : 1043 - 1043