Modular head-mounted cortical imaging device for chronic monitoring of intrinsic signals in mice

被引:8
|
作者
Guinto, Mark Christian [1 ]
Haruta, Makito [1 ]
Kurauchi, Yuki [2 ]
Saigo, Taisuke [1 ]
Kurasawa, Kazuki [1 ]
Ryu, Sumika [2 ]
Ohta, Yasumi [1 ]
Kawahara, Mamiko [1 ]
Takehara, Hironari [1 ]
Tashiro, Hiroyuki [1 ,3 ]
Sasagawa, Kiyotaka [1 ]
Katsuki, Hiroshi [2 ]
Ohta, Jun [1 ]
机构
[1] Nara Inst Sci & Technol, Grad Sch Sci & Technol, Div Mat Sci, Ikoma, Japan
[2] Kumamoto Univ, Grad Sch Pharmaceut Sci, Dept Chem Sci, Kumamoto, Japan
[3] Kyushu Univ, Div Med Technol, Dept Hlth Sci, Fac Med Sci, Fukuoka, Japan
关键词
intrinsic optical signal; cortical imaging; CMOS; head-mounted devices; chronic imaging; LONG-TERM; NEURAL ACTIVITY; HEMODYNAMIC-RESPONSES; VISUAL-CORTEX; BLOOD-FLOW; BRAIN; OXYGENATION; REVEALS; MAPS; INTEGRATION;
D O I
10.1117/1.JBO.27.2.026501
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Significance: Intrinsic optical signals (IOS) generated in the cortical tissue as a result of various interacting metabolic processes are used extensively to elucidate the underlying mechanisms that govern neurovascular coupling. However, current IOS measurements still often rely on bulky, tabletop imaging systems, and there remains a dearth of studies in freely moving subjects. Lightweight, miniature head-mounted imaging devices provide unique opportunities for investigating cortical dynamics in small animals under a variety of naturalistic behavioral settings. Aim: The aim of this work was to monitor IOS in the somatosensory cortex of wild-type mice by developing a lightweight, biocompatible imaging device that readily lends itself to animal experiments in freely moving conditions. Approach: Herein we describe a method for realizing long-term IOS imaging in mice using a 0.54-g, compact, CMOS-based, head-mounted imager. The two-part module, consisting of a tethered sensor plate and a base plate, allows facile assembly prior to imaging sessions and disassembly when the sensor is not in use. LEDs integrated into the device were chosen to illuminate the cortical mantle at two different wavelengths in the visible regime (. center: 535 and 625 nm) for monitoring volume- and oxygenation state-dependent changes in the IOS, respectively. To test whether the system can detect robust cortical responses, we recorded sensoryevoked IOS from mechanical stimulation of the hindlimbs (HL) of anesthetized mice in both acute and long-term implantation conditions. Results: Cortical IOS recordings in the primary somatosensory cortex hindlimb receptive field (S1HL) of anesthetized mice under green and red LED illumination revealed robust, multiphasic profiles that were time-locked to the mechanical stimulation of the contralateral plantar hindpaw. Similar intrinsic signal profiles observed in S1HL at 40 days postimplantation demonstrated the viability of the approach for long-term imaging. Immunohistochemical analysis showed that the brain tissue did not exhibit appreciable immune response due to the device implantation and operation. A proof-of-principle imaging session in a freely behaving mouse showed minimal locomotor impediment for the animal and also enabled estimation of blood flow speed. Conclusions: We demonstrate the utility of a miniature cortical imaging device for monitoring IOS and related hemodynamic processes in both anesthetized and freely moving mice, cueing potential for applications to some neuroscientific studies of sensation and naturalistic behavior.
引用
收藏
页数:20
相关论文
共 50 条
  • [1] A head-mounted photoacoustic fiberscope for hemodynamic imaging in mobile mice
    Zheng, Xiaoyan
    Na, Shuai
    [J]. LIGHT-SCIENCE & APPLICATIONS, 2024, 13 (01)
  • [2] An Inconspicuous and Modular Head-Mounted Eye Tracker
    Eivazi, Shaharam
    Kuebler, Thomas C.
    Santini, Thiago
    Kasneci, Enkelejda
    [J]. 2018 ACM SYMPOSIUM ON EYE TRACKING RESEARCH & APPLICATIONS (ETRA 2018), 2018,
  • [3] Patient monitoring with head-mounted displays
    Liu, David
    Jenkins, Simon A.
    Sanderson, Penelope M.
    [J]. CURRENT OPINION IN ANESTHESIOLOGY, 2009, 22 (06) : 796 - 803
  • [4] Imaging Cortical Dynamics in GCaMP Transgenic Rats with a Head-Mounted Widefield Macroscope
    Scott, Benjamin B.
    Thiberge, Stephan Y.
    Guo, Caiying
    Tervo, D. Gowanlock R.
    Brody, Carlos D.
    Karpova, Alla Y.
    Tank, David W.
    [J]. NEURON, 2018, 100 (05) : 1045 - +
  • [5] Chronic monitoring of cortical hemodynamics in behaving, freely-moving rats using a miniaturized head-mounted optical microscope
    Sigal, Iliya
    Gad, Raanan
    Koletar, Margaret
    Ringuette, Dene
    Stefanovic, Bojana
    Levi, Ofer
    [J]. CLINICAL AND TRANSLATIONAL NEUROPHOTONICS; NEURAL IMAGING AND SENSING; AND OPTOGENETICS AND OPTICAL MANIPULATION, 2016, 9690
  • [6] Development of Head-mounted Color Imaging Sonar
    Zhou, Wenjia
    Zhang, Chunlong
    [J]. 2016 IEEE INTERNATIONAL CONFERENCE ON ELECTRONIC INFORMATION AND COMMUNICATION TECHNOLOGY ICEICT 2016 PROCEEDINGS, 2016, : 363 - 366
  • [7] Assistive Pointing Device Based on a Head-Mounted Camera
    Walsh, Edwin
    Daems, Walter
    Steckel, Jan
    [J]. IEEE TRANSACTIONS ON HUMAN-MACHINE SYSTEMS, 2017, 47 (04) : 590 - 597
  • [8] Design of lighting system for head-mounted display device
    Xing, Chunlei
    Chen, Yujie
    Xu, Feng
    Ma, Suodong
    [J]. AOPC 2021: MICRO-OPTICS AND MOEMS, 2021, 12066
  • [9] Tactile Language for a Head-Mounted Sensory Augmentation Device
    Kerdegari, Hamideh
    Kim, Yeongmi
    Prescott, Tony
    [J]. BIOMIMETIC AND BIOHYBRID SYSTEMS, LIVING MACHINES 2015, 2015, 9222 : 359 - 365
  • [10] Monitoring of postural sway with a head-mounted wearable device: effects of gender, participant state, and concussion
    Grafton, Scott T.
    Ralston, Andreas B.
    Ralston, John D.
    [J]. MEDICAL DEVICES-EVIDENCE AND RESEARCH, 2019, 12 : 151 - 164