Circulating Tumour Cell Release after Cement Augmentation of Vertebral Metastases

被引:32
|
作者
Mohme, Malte [1 ]
Riethdorf, Sabine [2 ]
Dreimann, Marc [3 ]
Werner, Stefan [2 ]
Maire, Cecile L. [1 ]
Joosse, Simon A. [2 ]
Bludau, Frederic [4 ]
Mueller, Volkmar [5 ]
Neves, Rui P. L. [6 ,7 ]
Stoecklein, Nikolas H. [6 ,7 ]
Lamszus, Katrin [1 ]
Westphal, Manfred [1 ]
Pantel, Klaus [2 ]
Wikman, Harriet [2 ]
Eicker, Sven O. [1 ]
机构
[1] Univ Med Ctr Hamburg Eppendorf, Dept Neurosurg, Hamburg, Germany
[2] Univ Med Ctr Hamburg Eppendorf, Dept Tumor Biol, Hamburg, Germany
[3] Univ Med Ctr Hamburg Eppendorf, Dept Trauma Hand & Reconstruct Surg, Hamburg, Germany
[4] Heidelberg Univ, Univ Med Ctr Mannheim, Dept Trauma Surg, Heidelberg, Germany
[5] Univ Med Ctr Hamburg Eppendorf, Dept Gynecol, Hamburg, Germany
[6] Heinrich Heine Univ Dusseldorf, Univ Hosp, Dept Gen Visceral & Pediat Surg, Dusseldorf, Germany
[7] Heinrich Heine Univ Dusseldorf, Med Fac, Dusseldorf, Germany
来源
SCIENTIFIC REPORTS | 2017年 / 7卷
关键词
NO-TOUCH ISOLATION; PERCUTANEOUS VERTEBROPLASTY; BREAST-CANCER; SPINAL METASTASES; PERIPHERAL-BLOOD; CONTROLLED-TRIAL; POOLED ANALYSIS; DISSEMINATION; SURVIVAL; RECURRENCE;
D O I
10.1038/s41598-017-07649-z
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Cement augmentation via percutaneous vertebroplasty or kyphoplasty for treatment of spinal metastasis is a well-established treatment option. We assessed whether elevated intrametastatic pressure during cement augmentation results in an increased dissemination of tumour cells into the vascular circulation. We prospectively collected blood from patients with osteolytic spinal column metastases and analysed the prevalence of circulating tumour cells (CTCs) at three time-points: preoperatively, 20 minutes after cement augmentation, and 3-5 days postoperatively. Enrolling 21 patients, including 13 breast-(61.9%), 5 lung-(23.8%), and one (4.8%) colorectal-,renal-,and prostate-carcinoma patient each, we demonstrate a significant 1.8-fold increase of EpCAM+/K+ CTCs in samples taken 20 minutes post-cement augmentation (P < 0.0001). Despite increased mechanical CTC dissemination due to cement augmentation, follow-up blood draws demonstrated that no long-term increase of CTCs was present. Array-CGH analysis revealed a specific profile of the CTC collected 20 minutes after cement augmentation. This is the first study to report that peripheral CTCs are temporarily increased due to vertebral cement augmentation procedures. Our findings provide a rationale for the development of new prophylactic strategies to reduce the increased release of CTC after cement augmentation of osteolytic spinal metastases.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Circulating Tumour Cell Release after Cement Augmentation of Vertebral Metastases
    Malte Mohme
    Sabine Riethdorf
    Marc Dreimann
    Stefan Werner
    Cecile L. Maire
    Simon A. Joosse
    Frederic Bludau
    Volkmar Mueller
    Rui P. L. Neves
    Nikolas H. Stoecklein
    Katrin Lamszus
    Manfred Westphal
    Klaus Pantel
    Harriet Wikman
    Sven O. Eicker
    Scientific Reports, 7
  • [2] Cement Leakage after Augmentation of Osteoporotic Vertebral Bodies
    Aziz, Mina
    Kniep, Inga
    Ondruschka, Benjamin
    Pueschel, Klaus
    Hessler, Christian
    ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2024,
  • [3] Revision surgery after cement augmentation for osteoporotic vertebral fracture
    Hu, Xudong
    Jiang, Weiyu
    Chen, Yunlin
    Wang, Yang
    Ma, Weihu
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2021, 107 (07)
  • [4] Pulmonary Artery Cement Embolization After Vertebral Augmentation Procedures
    Malik, Adil
    Litz, Cristen
    Tran, Nam
    Moodie, Carla
    Garrett, Joseph
    Fontaine, Jacques-Pierre
    Toloza, Eric
    CHEST, 2017, 152 (04) : 1022A - 1022A
  • [5] Cement augmentation in vertebral burst fractures
    Zaryanov, Anton V.
    Park, Daniel K.
    Khalil, Jad G.
    Baker, Kevin C.
    Fischgrund, Jeffrey S.
    NEUROSURGICAL FOCUS, 2014, 37 (01)
  • [6] Sandwich Vertebral Fracture in the Study of Adjacent-level Fracture After Vertebral Cement Augmentation
    Wang, Lijun
    Yang, Huilin
    Shi, Yuanxin
    Luo, Zongping
    Jiang, Weimin
    Bao, Zhaohua
    Chen, Kangwu
    Wang, Genlin
    ORTHOPEDICS, 2012, 35 (08) : E1225 - E1230
  • [7] Risk factors for bone cement displacement after percutaneous vertebral augmentation for osteoporotic vertebral compression fractures
    Gao, Xiangcheng
    Du, Jinpeng
    Gao, Lin
    Hao, Dingjun
    Hui, Hua
    He, Baorong
    Yan, Liang
    FRONTIERS IN SURGERY, 2022, 9
  • [8] Development of a clinical predictive model for cement loosening after vertebral augmentation in osteoporotic vertebral compression fractures
    Wei, Qipeng
    Zhan, Jinxiang
    Chen, Xiaofeng
    Li, Hao
    Guo, Weijun
    Liu, Zihao
    Huang, Qingyan
    Cai, Dongling
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
  • [9] Inexpensive bone cement substitute for vertebral cement augmentation training
    Hollensteiner, Marianne
    Samrykit, Markus
    Hess, Michael
    Fuerst, David
    Esterer, Benjamin
    Schrempf, Andreas
    2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 2202 - 2205
  • [10] Percutaneous cement augmentation for osteoporotic vertebral fractures
    Sebaaly, Amer
    Rizkallah, Maroun
    Bachour, Falah
    Atallah, Firas
    Moreau, Pierre Emmanuel
    Maalouf, Ghassan
    EFORT OPEN REVIEWS, 2017, 2 (06): : 293 - 299