In maintenance hemodialysis patients lean body mass can be evaluated by bioelectrical impedance analysis

被引:0
|
作者
Ben Halim, A. [1 ]
Khedr, B. [1 ]
Capria, F. [1 ]
Mazzantini, M. [1 ]
Donadio, C. [1 ]
机构
[1] Univ Pisa, Dept Internal Med, Pisa, Italy
关键词
body composition; lean body mass; DXA; BIA; hemodialysis;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In maintenance hemodialysis patients (MHD) analysis of body composition is a key point to assess nutritional status. Dual-energy X-ray absorptiometry (DXA) is a reference method for a detailed assessment of fat mass (FM) and lean body mass (LBM). The reliability of single-frequency bioelectrical impedance (sf-BIA) versus multi-frequency (mf-BIA) to analyze body composition in MHD is debated. Aim: to evaluate the adequacy of sf-BIA and mf-BIA, in comparison with DXA, to evaluate LBM in MHD patients. Patients (9f, 18 m), 32-88 yrs, BW 42-94 kg, BMI 17.5-34.4 kg/m(2), on MHD since 0.5-17.4 years. LBM was measured, in the interdialytic period, with DXA and BIA,with 2 sf-BIA and with I mf-BIA analyzer. A very close correlation was found between LBM-BIA and LBM-DXA (R 0.901 - 0.921). Mean values of LBM were very similar with the different techniques. LBM was 45.1.1 +/- 8.8 kg (DXA); 45.1 +/- 8.5 (sfl-BILA); 45.8 +/- 8.8 (sf2-BIA); 44.4 +/- 11.5 (mf-BIA). Prediction errors were 3.4 kg for sf1-BIA, 4.0 kg for sf2-BIA, and 5.0 kg for mf-BIA. In conclusion, BIA is a reliable method to evaluate lean body mass in MHD.
引用
收藏
页码:767 / 770
页数:4
相关论文
共 50 条
  • [1] Appendicular lean body mass - Prediction by bioelectrical impedance analysis
    Tagliabue, A
    Andreoli, A
    Bertoli, S
    Pagliato, E
    Comelli, M
    Testolin, G
    De Lorenzo, A
    [J]. IN VIVO BODY COMPOSITION STUDIES, 2000, 904 : 218 - 220
  • [2] Assessing lean tissue by bioelectrical impedance analysis pre hemodialysis underestimates the prevalence of sarcopenia in maintenance hemodialysis patients
    Wang, Minmin
    Liu, Lin
    Shen, Xiaogang
    Li, Yiwen
    He, Qiang
    [J]. EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2021, 75 (09) : 1407 - 1413
  • [3] Assessing lean tissue by bioelectrical impedance analysis pre hemodialysis underestimates the prevalence of sarcopenia in maintenance hemodialysis patients
    Minmin Wang
    Lin Liu
    Xiaogang Shen
    Yiwen Li
    Qiang He
    [J]. European Journal of Clinical Nutrition, 2021, 75 : 1407 - 1413
  • [4] The impact of equations on calculation of lean body mass by bioelectrical impedance analysis in RDT patients
    Oe, B
    De Fijter, CWH
    Geers, ABM
    Vos, PF
    Donker, AJM
    De Vries, PMJM
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2000, 23 (03): : 168 - 172
  • [6] Correction to: Assessing lean tissue by bioelectrical impedance analysis pre hemodialysis underestimates the prevalence of sarcopenia in maintenance hemodialysis patients
    Minmin Wang
    Lin Liu
    Xiaogang Shen
    Yiwen Li
    Qiang He
    [J]. European Journal of Clinical Nutrition, 2022, 76 : 334 - 334
  • [7] ESTIMATION OF LEAN BODY-MASS BY BIOELECTRICAL IMPEDANCE
    NELSON, MV
    [J]. AMERICAN JOURNAL OF CLINICAL NUTRITION, 1989, 49 (01): : 184 - 185
  • [8] COMPARISON OF SINGLE AND MULTIFREQUENCY BIOELECTRICAL IMPEDANCE ANALYSIS WITH DUAL-ENERGY X-RAY ABSORPTIOMETRY FOR THE ASSESSMENT OF BODY FAT AND LEAN MASS IN PATIENTS ON MAINTENANCE HEMODIALYSIS
    Nogueira, Suellen C. A.
    Antonio, Karina J.
    Vogt, Barbara P.
    Caramori, Jacqueline C. T.
    [J]. NEPHROLOGY DIALYSIS TRANSPLANTATION, 2015, 30
  • [9] Each of anthropometry, bioelectrical impedance analysis and dual-energy X-ray absorptiometry methods can be used to assess lean body mass in hemodialysis patients
    Chen, YC
    Chen, HH
    Yeh, JC
    Chen, SY
    Lin, KW
    [J]. NEPHRON, 2000, 84 (04): : 374 - 375
  • [10] ESTIMATION OF LEAN BODY-MASS BY BIOELECTRICAL IMPEDANCE - REPLY
    SEGAL, KR
    VANLOAN, M
    [J]. AMERICAN JOURNAL OF CLINICAL NUTRITION, 1989, 49 (01): : 185 - 185