IMRT: delivery techniques and quality assurance

被引:35
|
作者
Williams, PC [1 ]
机构
[1] Christie Hosp NHS Trust, N Western Med Phys, Manchester M20 4BX, Lancs, England
来源
BRITISH JOURNAL OF RADIOLOGY | 2003年 / 76卷 / 911期
关键词
D O I
10.1259/bjr/12907222
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Intensity modulated radiotherapy (IMRT) is a major development in the delivery of radiation therapy that has the potential to improve patient outcome by reducing morbidity or increasing local tumour control. Delivery techniques include those based on purpose built devices and treatment machines together with those utilizing the capabilities of computer controlled multileaf collimators which are more widely available. The complexity of IMRT techniques demands a high level of quality control both in the operation of the equipment and in the delivery of treatment to individual patients. The purpose of this paper is therefore to review the techniques available, concentrating on the use of multileaf collimators, and to consider the necessary quality control requirements for clinical application. It demonstrates that the technology is mature and sufficiently well understood so that IMRT can be safely implemented in the general clinical environment rather than being limited to application in the research environment.
引用
收藏
页码:766 / 776
页数:11
相关论文
共 50 条
  • [1] Quality assurance of IMRT delivery systems - Siemens
    Verhey, L
    Xia, P
    [J]. MEDICAL PHYSICS, 2002, 29 (06) : 1280 - 1280
  • [2] A Comparison of Four IMRT Quality Assurance Techniques
    McKissick, M.
    Duggan, D.
    Gaiser, J.
    [J]. MEDICAL PHYSICS, 2010, 37 (06)
  • [3] MLC quality assurance techniques for IMRT applications
    Bayouth, JE
    Wendt, D
    Morrill, SM
    [J]. MEDICAL PHYSICS, 2003, 30 (05) : 743 - 750
  • [4] CE-IMRT 1: Quality assurance of IMRT delivery systems - Elekta
    Sharpe, M
    [J]. MEDICAL PHYSICS, 2002, 29 (06) : 1280 - 1280
  • [5] CE-IMRT 1: Quality assurance of IMRT delivery systems - Varian
    LoSasso, T
    [J]. MEDICAL PHYSICS, 2002, 29 (06) : 1279 - 1280
  • [6] Dynamic delivery quality assurance for IMRT to account for target motion
    Jaradat, H. A.
    Mehta, M.
    Nelson, K.
    Schmidt, D.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S711 - S712
  • [7] Quality assurance of IMRT
    Chui, CS
    LoSasso, T
    [J]. USE OF COMPUTERS IN RADIATION THERAPY, 2000, : 168 - 169
  • [8] Quality assurance and validation of individual IMRT treatment plans before delivery
    Niemierko, A
    [J]. MEDICAL PHYSICS, 2004, 31 (02) : 421 - 422
  • [9] Patient-specific quality assurance for IMRT delivery: A multicentre study
    Hizam, Diyana Afrina
    Jong, Wei Loong
    Zin, Hafiz Mohd
    Ng, Kwan Hoong
    Ung, Ngie Min
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2023, 209
  • [10] IMRT system quality assurance
    Low, D
    [J]. MEDICAL PHYSICS, 2003, 30 (06) : 1412 - 1412