Integrated SDS Removal and Peptide Separation by Strong-Cation Exchange Liquid Chromatography for SDS-Assisted Shotgun Proteome Analysis

被引:31
|
作者
Sun, Difei [1 ]
Wang, Nan [1 ]
Li, Liang [1 ]
机构
[1] Univ Alberta, Dept Chem, Edmonton, AB T6G 2G2, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
shotgun proteome analysis; surfactants; SDS removal; membrane proteome; strong-cation exchange; LC-MS/MS; SODIUM DODECYL-SULFATE; SPECTROMETRY-COMPATIBLE SURFACTANTS; IONIZATION MASS-SPECTROMETRY; SAMPLE PREPARATION; LC-MS/MS; ENZYMATIC DIGESTION; MEMBRANE-PROTEINS; IDENTIFICATION; QUANTIFICATION; OPTIMIZATION;
D O I
10.1021/pr200676v
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We report an improved shotgun method for analyzing proteomic samples containing sodium dodecyl sulfate (SDS). This method is based on the use of strong-cation exchange (SCX) liquid chromatography (LC) for SDS removal that can be integrated with peptide separation as the first dimension of the two-dimensional LC tandem mass spectrometry workflow. To optimize the performance of SDS removal, various experimental conditions, including the concentrations of chemical reagents and salts in the sample, the SDS concentration, and the SCX mobile phase composition, were investigated. It was found that a peptide recovery rate of about 90% could be achieved while removing SDS efficiently. One key finding was that, by increasing the SDS concentration to a certain level (0.5%) in the digested peptide sample, the sample recovery rate could be increased. The peptide recovery rate of BSA digests was found to be 90.6 +/- 1.0% (n = 3), and SDS in the SCX fractions collected was not detectable by pyrolysis GC-MS, i.e., below the detection limit of 0.00006% for the undesalted SCX fractions. The peptide recovery rates were found to be 90.9% +/- 2.7 (n = 3) and 89.5% +/- 0.5% (n = 3) for the digests of the membrane-protein-enriched fractions of E. coli cell lysates and the MCF-7 breast cancer cell line, respectively. Compared to the methods that use acid-labile surfactants, such as RapiGest and PPS, for the MCF-7 membrane fraction sample, the SDS method identified, on average (n = 3), more peptides (similar to 5%) and proteins (similar to 16%) than the RapiGest method, while the RapiGest method identified more peptides (similar to 21%) and proteins (similar to 7%) from the E. coli membrane fraction than the SDS method. In both cases, the two methods identified more peptides and proteins than the PPS method. Since SCX is widely used as the first dimension of 2D-LC MS/MS, integration of SDS removal with peptide separation in SCX does not add any extra steps to the sample handling process. We demonstrated the application of this method for 2D-LC MS/MS profiling of the MCF-7 membrane protein fraction and identified 6889 unique peptides, corresponding to 2258 unique proteins or protein groups from two replicate experiments with a false peptide discovery rate of, similar to 0.8%, compared to 5172 unique peptides and 1847 unique proteins identified by the RapiGest method.
引用
收藏
页码:818 / 828
页数:11
相关论文
共 49 条
  • [1] Integrated SDS removal and protein digestion by hollow fiber membrane based device for SDS-assisted proteome analysis
    Xia, Simin
    Yuan, Huiming
    Chen, Yuanbo
    Liang, Zheng
    Zhang, Lihua
    Zhang, Yukui
    [J]. TALANTA, 2015, 141 : 235 - 238
  • [2] Shotgun analysis of membrane proteomes by an improved SDS-assisted sample preparation method coupled with liquid chromatography-tandem mass spectrometry
    Lin, Yong
    Jiang, Huajun
    Yan, Yujun
    Peng, Bin
    Chen, Jinhua
    Lin, Haiyan
    Liu, Zhonghua
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 911 : 6 - 14
  • [3] Preparation of a strong-cation exchange monolith by a novel method and its application in the separation of IgG on high performance liquid chromatography
    Yang, Gengliang
    Bai, Ligai
    Yan, Cuihong
    Gu, Yanzhao
    Ma, Junjie
    [J]. TALANTA, 2011, 85 (05) : 2666 - 2672
  • [4] Comparison of Strong Cation Exchange and SDS-PAGE Fractionation for Analysis of Multiprotein Complexes
    Das, Sudipto
    Bosley, Allen D.
    Ye, Xiaoying
    Chan, King C.
    Chu, Isabel
    Green, Jeffery E.
    Issaq, Haleem J.
    Veenstra, Timothy D.
    Andresson, Thorkell
    [J]. JOURNAL OF PROTEOME RESEARCH, 2010, 9 (12) : 6696 - 6704
  • [5] Capillary trap column with strong cation-exchange monolith for automated shotgun proteome analysis
    Wang, Fangjun
    Dong, Jing
    Jiang, Xiaogang
    Ye, Mingliang
    Zou, Hanfa
    [J]. ANALYTICAL CHEMISTRY, 2007, 79 (17) : 6599 - 6606
  • [6] Artificial neural network prediction of peptide separation in strong cation exchange chromatography
    Oh, C.
    Mirzaei, H.
    Regnier, F. E.
    Zhang, X.
    [J]. MOLECULAR & CELLULAR PROTEOMICS, 2006, 5 (10) : S112 - S112
  • [7] Optimization of conditions for the separation of peptide mixtures using strong cation exchange chromatography
    Wang Lu
    Zhou Lanlan
    Qian Xiaohong
    Zhang Yangjun
    [J]. CHINESE JOURNAL OF CHROMATOGRAPHY, 2010, 28 (04) : 368 - 373
  • [8] Recent advances in peptide separation by multidimensional liquid chromatography for proteome analysis
    Di Palma, Serena
    Hennrich, Marco L.
    Heck, Albert J. R.
    Mohammed, Shabaz
    [J]. JOURNAL OF PROTEOMICS, 2012, 75 (13) : 3791 - 3813
  • [9] Nano-flow multidimensional liquid chromatography platform integrated with combination of protein and peptide separation for proteome analysis
    Xia, Simin
    Tao, Dingyin
    Yuan, Huiming
    Zhou, Yuan
    Liang, Zhen
    Zhang, Lihua
    Zhang, Yukui
    [J]. JOURNAL OF SEPARATION SCIENCE, 2012, 35 (14) : 1764 - 1770
  • [10] Automation of nanoflow liquid chromatography-tandem mass spectrometry for proteome analysis by using a strong cation exchange trap column
    Jiang, Xiaogang
    Feng, Shun
    Tian, Ruijun
    Han, Guanghui
    Jiang, Xinning
    Ye, Mingliang
    Zou, Hanfa
    [J]. PROTEOMICS, 2007, 7 (04) : 528 - 539