The passive leg-raising maneuver cannot accurately predict fluid responsiveness in patients with intra-abdominal hypertension

被引:148
|
作者
Mahjoub, Yazine [1 ,4 ]
Touzeau, Jeremie [1 ]
Airapetian, Norair [1 ]
Lorne, Emmanuel [4 ]
Hijazi, Mustapha [1 ]
Zogheib, Elie [1 ]
Tinturier, Francois [1 ]
Slama, Michel [2 ,3 ,4 ]
Dupont, Herve [1 ,4 ]
机构
[1] Amiens Univ, Med Ctr, Med & Surg Intens Care Unit, Dept Anesthesia & Intens Care, Amiens, France
[2] Amiens Univ, Med Ctr, Med Intens Care Unit, Dept Nephrol, Amiens, France
[3] Amiens Univ, Med Ctr, Med Intens Care Unit, Amiens, France
[4] Jules Verne Univ Picardie, INSERM, ERI 12, Amiens, France
关键词
fluid responsiveness; passive leg raising; intra-abdominal hypertension; false negative; CRITICALLY-ILL PATIENTS; PULSE PRESSURE VARIATION; INCREASED ABDOMINAL PRESSURE; TRANSESOPHAGEAL DOPPLER; CARDIAC-OUTPUT; ESOPHAGEAL DOPPLER; BLOOD-FLOW; PERFORMANCE; SURGERY; PNEUMOPERITONEUM;
D O I
10.1097/CCM.0b013e3181eb3c21
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objectives: The passive leg-raising maneuver is a reversible fluid-loading procedure used to predict fluid responsiveness in mechanically ventilated patients. The aim of the present study was to determine whether intra-abdominal hypertension (which impairs venous return) reduces the ability of passive leg raising to detect fluid responsiveness in critically ill ventilated patients. Design: A prospective study. Setting: The medical and surgical intensive care unit of a university medical center. Patients: Forty-one mechanically ventilated patients with a pulse pressure variation of >12%. Interventions: Stroke volume was continuously monitored by esophageal Doppler. Intra-abdominal pressure was measured via bladder pressure. After a passive leg-raising maneuver and a return to baseline, fluid loading with 500 mL of saline was performed. Hemodynamic parameters were recorded at each step. Nonresponders to volume loading were not analyzed (10 patients). Thirty-one patients were classified into two groups according to their response to passive leg raising: responders to passive leg raising (at least a 12% increase in stroke volume) and nonresponders to passive leg raising. Measurements and Main Results: Sixteen patients (52%) were responders to passive leg raising, and 15 (48%) were nonresponders to passive leg raising (i.e., false negatives). At baseline, the median intra-abdominal pressure was significantly higher in the nonresponders to passive leg raising than in the responders to passive leg raising (20 [6.5] vs. 11.5 [5.5], respectively; p < .0001). The area under the receiver-operating characteristic curve was 0.969 +/- 0.033. An intra-abdominal pressure cutoff value of 16 mm Hg discriminated between responders to passive leg raising and nonresponders to passive leg raising with a sensitivity of 100% (confidence interval, 78-100) and a specificity of 87.5% (confidence interval, 61.6-98.1). An intra-abdominal pressure of >= 16 mm Hg was the only independent predictor of nonresponse to passive leg raising in a multivariate analysis (odds ratio, 2.6 [confidence interval, 1.1-6.6]; p = .04). Conclusions: An intra-abdominal pressure of >= 16 mm Hg seems to be responsible for false negatives to passive leg raising. Hence, the intra-abdominal pressure should be measured in critically ill ventilated patients, especially before performing passive leg raising. (Crit Care Med 2010; 38:1824-1829)
引用
收藏
页码:1824 / 1829
页数:6
相关论文
共 50 条
  • [1] Passive Leg-Raising and Prediction of Fluid Responsiveness
    Picket, J. D.
    Bridges, E.
    Kritek, P. A.
    Whitney, J. D.
    CRITICAL CARE NURSE, 2017, 37 (02) : 48 - 48
  • [2] Assessing fluid responsiveness with the passive leg raising maneuver in patients with increased intra-abdominal pressure: Be aware that not all blood returns!
    Malbrain, Manu L. N. G.
    Reuter, Daniel A.
    CRITICAL CARE MEDICINE, 2010, 38 (09) : 1912 - 1915
  • [3] Predicting fluid responsiveness with the passive leg raising test: don't be fooled by intra-abdominal hypertension!
    Minini, Andrea
    Abraham, Paul
    Malbrain, Manu L. N. G.
    ANNALS OF TRANSLATIONAL MEDICINE, 2020, 8 (12)
  • [4] Passive leg raising test in patients with intra-abdominal hypertension: do not throw it
    Beurton, Alexandra
    Teboul, Jean-Louis
    Monnet, Xavier
    ANNALS OF TRANSLATIONAL MEDICINE, 2020, 8 (12)
  • [5] Passive Leg-Raising and Prediction of Fluid Responsiveness: Systematic Review
    Pickett, Joya D.
    Bridges, Elizabeth
    Kritek, Patricia A.
    Whitney, JoAnne D.
    CRITICAL CARE NURSE, 2017, 37 (02) : 32 - 47
  • [6] The passive leg raising under pressure: focus on the impact of intra-abdominal hypertension
    Beaucote, Victor
    Geri, Guillaume
    Vieillard-Baron, Antoine
    ANNALS OF TRANSLATIONAL MEDICINE, 2020, 8 (12)
  • [7] Intra-Abdominal Hypertension Is Responsible for False Negatives to the Passive Leg Raising Test
    Beurton, Alexandra
    Teboul, Jean-Louis
    Girotto, Valentina
    Galarza, Laura
    Anguel, Nadia
    Richard, Christian
    Monnet, Xavier
    CRITICAL CARE MEDICINE, 2019, 47 (08) : E639 - E647
  • [8] ASSESSMENT OF FLUID RESPONSIVENESS BY CHANGES IN PARTIAL ENDTIDAL CO2 PRESSURE DURING PASSIVE LEG-RAISING MANEUVER
    Monge Garcia, M. I.
    Gil Cano, A.
    Gracia Romero, M.
    Perez Madueno, V.
    Monterroso Pintado, R.
    INTENSIVE CARE MEDICINE, 2011, 37 : S89 - S89
  • [9] Use of a modified passive leg-raising maneuver to predict fluid responsiveness during experimental induction and correction of hypovolemia in healthy isoflurane-anesthetized pigs
    Paranjape, Vaidehi V.
    Shih, Andre C.
    Garcia-Pereira, Fernando L.
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2019, 80 (01) : 24 - 32
  • [10] Assessment of fluid responsiveness with end-tidal carbon dioxide using a simplified passive leg-raising maneuver: a prospective observational study
    Barak, Michal
    Yussim, Eliot
    CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2017, 64 (05): : 546 - 546