Acute outcomes of three-dimensional mapping for fluoroscopy reduction in paediatric catheter ablation for supraventricular tachycardia

被引:2
|
作者
Anderson, Chris [1 ]
Rahman, Maryam [2 ]
Bradley, David J. [3 ]
Breedlove, Kristen [2 ]
Dick, Macdonald [3 ]
LaPage, Martin J. [3 ]
Martinez, Alaina R. [4 ]
McNinch, Neil L. [4 ]
Moore, Jeremy P. [5 ]
Papagiannis, John [6 ]
Razminia, Mansour [7 ]
Shannon, Kevin M. [5 ]
Shauver, Lisa M. [4 ]
Tuzcu, Volkan [8 ]
Clark, John M. [2 ]
机构
[1] Providence Sacred Heart Childrens Hosp, Ctr Congenital Heart Dis, Spokane, WA USA
[2] Akron Childrens Hosp, Heart Ctr, One Perkins Sq, Akron, OH 44308 USA
[3] Univ Michigan, CS Mott Childrens Hosp, Div Pediat Cardiol, Ann Arbor, MI 48109 USA
[4] Akron Childrens Hosp, Rebecca D Considine Res Inst, Akron, OH 44308 USA
[5] UCLA Mattel Childrens Hosp, Dept Pediat, Div Pediat Cardiol, Los Angeles, CA USA
[6] Childrens Mercy Hosp, Div Cardiol, Kansas City, MO 64108 USA
[7] Amita Hlth St Joseph Hosp, Clin Cardiac Electrophysiol, Elgin, IL USA
[8] Istanbul Medipol Univ Hosp, Dept Pediat Cardiol Electrophysiol, Istanbul, Turkey
关键词
Catheter ablation; three-dimensional mapping; fluoroscopy; radiation; supraventricular tachycardia; paediatric; CRYOTHERMAL ABLATION; RADIATION EXPOSURE; ACCESSORY PATHWAYS; IONIZING-RADIATION; ELECTROPHYSIOLOGY; CRYOABLATION; ELIMINATION; CHILDREN;
D O I
10.1017/S1047951121001086
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Catheter ablation is a safe and effective therapy for the treatment of supraventricular tachycardia in children. Current improvements in technology have allowed progressive reduction in radiation exposure associated with the procedure. To assess the impact of three-dimensional mapping, we compared acute procedural results collected from the Catheter Ablation with Reduction or Elimination of Fluoroscopy registry to published results from the Prospective Assessment after Pediatric Cardiac Ablation study. Methods: Inclusion and exclusion criteria from the Prospective Assessment after Pediatric Cardiac Ablation study were used as guidelines to select patient data from the Catheter Ablation with Reduction or Elimination of Fluoroscopy registry to compare acute procedural outcomes between cohorts. Outcomes assessed include procedural and fluoroscopy exposure times, success rates of procedure, and complications. Results: In 786 ablation procedures, targeting 498 accessory pathways and 288 atrioventricular nodal reentrant tachycardia substrates, average procedural time (156.5 versus 206.7 minutes, p < 0.01), and fluoroscopy time (1.2 versus 38.3 minutes, p < 0.01) were significantly shorter in the study group. Success rates for the various substrates were similar except for manifest accessory pathways which had a significantly higher success rate in the study group (96.4% versus 93.0%, p < 0.01). Major complication rates were significantly lower in the study group (0.3% versus 1.6%, p < 0.01). Conclusions: In a large, multicentre study, three-dimensional systems show favourable improvements in clinical outcomes in children undergoing catheter ablation of supraventricular tachycardia compared to the traditional fluoroscopic approach. Further improvements are anticipated as technology advances.
引用
收藏
页码:1923 / 1928
页数:6
相关论文
共 50 条
  • [1] IMPROVED OUTCOMES OF SUPRAVENTRICULAR TACHYCARDIA ABLATIONS WITH THE USE OF THREE-DIMENSIONAL MAPPING
    Crass, Stephanie
    Manley-Casco, Dario
    Jevicks, Justin
    Mayo, MacKenzie
    Gundapaneni, Lakshmi Saroja
    Imtiaz, Komal
    Rajkumar, Dixy
    Battaglia, Michael
    Shinn, Timothy
    Greenstein, Radmira
    Ravindran, Bipin
    Han, Jihn
    Zishiri, Edwin
    Hebsur, Shrinivas
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 77 (18) : 414 - 414
  • [2] Catheter Ablation of Supraventricular Tachycardia Without Fluoroscopy During Pregnancy
    Clark, John M.
    Bigelow, Amee M.
    Crane, Stephen S.
    Khoury, Fadi R.
    OBSTETRICS AND GYNECOLOGY, 2014, 123 : 44S - 45S
  • [3] Catheter Ablation of Supraventricular Tachycardia Without Fluoroscopy During Pregnancy
    Bigelow, Amee M.
    Crane, Stephen S.
    Khoury, Fadi R.
    Clark, John M.
    OBSTETRICS AND GYNECOLOGY, 2015, 125 (06): : 1338 - 1341
  • [4] Three-dimensional noncontact mapping for catheter ablation of nonsustained monomorphic ventricular tachycardia
    Chen, J
    Hoff, PI
    Rossvoll, O
    Erga, KS
    Ohm, OJ
    EUROPEAN HEART JOURNAL, 2001, 22 : 696 - 696
  • [5] Catheter Ablation of Ventricular Tachycardia From Indication to Three-Dimensional Mapping Technology
    Eckardt, Lars
    Breithardt, Guenter
    HERZ, 2009, 34 (03) : 187 - 196
  • [6] Intraoperative Three-Dimensional Mapping of Supraventricular Tachycardia in a Young Fontan Patient
    Perry, James C.
    Williams, Matthew R.
    Shepard, Suzanne
    Bratincsak, Andras
    Murphy, Cynthia
    Murthy, Raghav
    Ebrahim, Mohammad
    Lamberti, John J.
    ANNALS OF THORACIC SURGERY, 2017, 103 (05): : E453 - E456
  • [7] Catheter ablation of ventricular tachycardia following myocardial infarction using three-dimensional electroanatomical mapping
    Kautzner, J
    Cihák, R
    Peichl, P
    Vancura, V
    Bytesník, J
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2003, 26 (01): : 342 - 347
  • [8] Noncontact three-dimensional mapping guides catheter ablation of difficult atrioventricular nodal reentrant tachycardia
    Lee, Pi-Chang
    Tai, Ching-Tai
    Lin, Yenn-Jiang
    Liu, Tu-Ying
    Huang, Bien-Hsien
    Higa, Satoshi
    Yuniadi, Yoga
    Lee, Kun-Tai
    Hwang, Betau
    Hwang, Betau
    Chen, Shih-Ann
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2007, 118 (02) : 154 - 163
  • [9] Epicardial mapping and radiofrequency catheter ablation of ischemic ventricular tachycardia using a three-dimensional nonfluoroscopic mapping system
    Tomassoni, G
    Stanton, M
    Richey, M
    Leonelli, FM
    Beheiry, S
    Natale, A
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1999, 10 (12) : 1643 - 1648
  • [10] Three-dimensional electromagnetic catheter technology: Electroanatomical mapping of the right atrium and ablation of ectopic atrial tachycardia
    Kottkamp, H
    Hindricks, G
    Breithardt, G
    Borggrefe, M
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1997, 8 (12) : 1332 - 1337