Hand-held dynamic contour tonometry

被引:9
|
作者
Knecht, Pascal B. [1 ]
Schmid, Ursina [1 ]
Romppainen, Timo [1 ]
Hediger, Annette [1 ]
Funk, Jens [1 ]
Kanngiesser, Hartmut [2 ]
Kniestedt, Christoph [1 ]
机构
[1] Univ Zurich Hosp, Dept Ophthalmol, Zurich, Switzerland
[2] Swiss Microtechnol AG, Port, Switzerland
关键词
dynamic contour tonometry; hand-held; Perkins; TonoPenXL; GOLDMANN APPLANATION TONOMETRY; INTRAOCULAR-PRESSURE MEASUREMENT; HUMAN CADAVER EYES; CORNEAL THICKNESS; GLAUCOMA;
D O I
10.1111/j.1755-3768.2009.01625.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: We present a prototype of the hand-held dynamic contour tonometer (HH-DCT) and prospectively compare this HH-DCT with the well-established Perkins applanation tonometer (PAT) and the TonoPenXL (TPXL). Methods: In a prospective, single-centre, randomized study, intraocular pressure (IOP) readings were taken in random order using HH-DCT, PAT and TPXL tonometers. Intra-observer variability was calculated for each observer and compared between three experienced ophthalmologists and an inexperienced medical student. Results: Ninety-two corneas of 92 healthy participants were enrolled. IOP [mean mmHg +/- standard deviation (SD)] as measured by HH-DCT was 16.97 +/- 2.71, by PAT 13.98 +/- 2.52 and by TPXL 13.34 +/- 2.68. The range of three consecutive IOP readings differed significantly between the devices [p < 0.001; mean range: 1.45 +/- 1.07 (HH-DCT), 1.87 +/- 0.97 (PAT) and 2.08 +/- 1.77 (TPXL)]. There was no difference of the range in all devices between the ophthalmologists and the medical student (HH-DCT p = 0.68, PAT p = 0.54, TPXL p = 0.48). Conclusion: IOP readings measured by HH-DCT are significantly higher than by PAT and TPXL. The differences of IOP measurements are in good accordance with previous studies using the slit-lamp-mounted DCT (SL-DCT) and Goldmann Applanation Tonometry, where SL-DCT readings were 1-3.2 mmHg higher. HH-DCT seems to give more constant results, which can be seen in the lower intra-observer variability compared to PAT and TPXL.
引用
收藏
页码:132 / 137
页数:6
相关论文
共 50 条
  • [1] Comparing dynamic contour tonometry to goldmann and hand-held tonometry in normal, ocular hypertension, and glaucoma populations
    Eichenbaum, Kenneth D.
    Mezei, Mihaly
    Eichenbaum, Joseph W.
    [J]. ANNALS OF OPHTHALMOLOGY, 2007, 39 (01) : 41 - 49
  • [2] A hand-held wide dynamic camera
    Lang, Yizheng
    Yan, Lei
    Yao, Ze
    Qian, Yunsheng
    [J]. SIXTH SYMPOSIUM ON NOVEL OPTOELECTRONIC DETECTION TECHNOLOGY AND APPLICATIONS, 2020, 11455
  • [3] A HAND-HELD DYNAMIC STRAIN GAUGE
    JACKSON, RS
    [J]. JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1968, 1 (09): : 937 - &
  • [4] Poor correlation between intracranial pressure and intraocular pressure by hand-held tonometry
    Golan, Shani
    Kurtz, Shimon
    Mezad-Koursh, Daphna
    Waisbourd, Michael
    Kesler, Anat
    Halpern, Pinchas
    [J]. CLINICAL OPHTHALMOLOGY, 2013, 7 : 1083 - 1087
  • [5] HAND-HELD - UPWARD MOBILITY THROUGH HAND-HELD TRANSCEIVERS
    GUSTAFSON, D
    [J]. AIR PROGRESS, 1985, 47 (03): : 30 - 32
  • [6] Dynamic Contour Tonometry
    Kanngiesser, HE
    Robert, YCA
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U59 - U59
  • [7] Dynamic contour tonometry
    Kniestedt, C.
    Kanngiesser, H. E.
    [J]. OPHTHALMOLOGE, 2006, 103 (08): : 713 - 721
  • [8] Intraocular pressure difference in goldmann applanation tonometry versus Perkins hand-held applanation tonometry in overweight patients
    dos Santos, MG
    Makk, S
    Berghold, A
    Eckhardt, M
    Haas, A
    [J]. OPHTHALMOLOGY, 1998, 105 (12) : 2260 - 2263
  • [9] Dynamic Object Localization Using Hand-held Cameras
    Gullapally, Sai Chowdary
    Malireddi, Sri Raghu
    Raman, Shanmuganathan
    [J]. 2015 TWENTY FIRST NATIONAL CONFERENCE ON COMMUNICATIONS (NCC), 2015,
  • [10] The width and height of a hand-held object by dynamic touch
    Turvey, MT
    Burton, G
    Amazeen, EL
    Butwill, M
    Carello, C
    [J]. JOURNAL OF EXPERIMENTAL PSYCHOLOGY-HUMAN PERCEPTION AND PERFORMANCE, 1998, 24 (01) : 35 - 48