Systolic time intervals as simple echocardiographic parameters of left ventricular systolic performance: correlation with ejection fraction and longitudinal two-dimensional strain

被引:87
|
作者
Reant, Patricia [1 ]
Dijos, Marina [1 ]
Donal, Erwan [2 ,3 ,4 ]
Mignot, Aude [1 ]
Ritter, Philippe [1 ]
Bordachar, Pierre [1 ]
Dos Santos, Pierre [1 ]
Leclercq, Christophe [2 ,3 ,4 ]
Roudaut, Raymond [1 ]
Habib, Gilbert [5 ]
Lafitte, Stephane [1 ]
机构
[1] Univ Bordeaux, CHU Bordeaux, Inserm U828, Dept Cardiol,CIC 0005, Bordeaux, France
[2] CHU Pontchaillou, Rennes, France
[3] Univ Rennes 1 France, CIC IT 804, Rennes, France
[4] INSERM, U642, Rennes, France
[5] Hop La Timone, Dept Cardiol, Marseille, France
来源
EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY | 2010年 / 11卷 / 10期
关键词
Left ventricular function; Echocardiography; Systolic time intervals; 2D strain; ACUTE MYOCARDIAL-INFARCTION; HEART-FAILURE; EXPERIMENTAL VALIDATION; ATRIAL-FIBRILLATION; NORMAL INDIVIDUALS; PRESSURE-FLOW; DISEASE; PERIOD; CARDIOMYOPATHY; CONTRACTILITY;
D O I
10.1093/ejechocard/jeq084
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Conventionally, the evaluation of left ventricular (LV) systolic function is based on ejection fraction assessment, which may be supplemented by other echocardiographic techniques, such as tissue Doppler imaging, 3D evaluation, and speckle tracking strains. However, these imaging modalities have a high technicity and are time-consuming, while being associated with reproducibility limitations. In this context, the usefulness of simpler measurements such as systolic time intervals (STI) by pulsed Doppler echocardiography must be emphasized. In this multicentre study, left ventricular ejection fraction (LVEF), dP/dt(max), LV stroke volume, myocardial longitudinal deformation, aortic pre-ejectional period (PEP, ms), and left ventricular ejection time (LVET, ms) were prospectively investigated and compared in 134 consecutive heart failure (HF) patients and 43 control subjects. Feasibility of STI measurements was 100%. Intra-observer reproducibility was 98% for PEP, 96% for LVET, 87% for LVEF, and 93% for global longitudinal strain (GLS). By subgroup analyses, with increasingly altered LVEF or GLS, PEP significantly increased, whereas significantly LVET decreased, resulting in a significantly increased PEP/LVET ratio (P < 0.001). In the HF patients group, a correlation between LVEF and PEP/LVET was found, with r = 0.55 (y = -0.0083x + 0.75, P < 0.001). Based on receiver operating curve analyses, the area under the curve was 0.91 for PEP/LVET > 0.43, which allowed us to detect LVEF < 35% with a sensitivity of 87%, and a specificity of 84%. STI can be easily and accurately measured in clinical practice, and may be used for detecting alterations in LV systolic function. Moreover, this method is likely to have potential applications in the management of HF patients.
引用
收藏
页码:834 / 844
页数:11
相关论文
共 50 条
  • [1] Three-dimensional echocardiographic analysis of electromechanical synchrony: comparison with threedimensional and two-dimensional ejection fraction for evaluation of left ventricular systolic performance
    Campos Vieira, Marcelo Luiz
    Cury, Alexandre Ferreira
    Frazatto Naccarato, Gustavo Alberto
    Alves de Oliveira, Wercules Antonio
    Cordovil, Adriana
    Tude Rodrigues, Ana Clara
    Monaco, Claudia Gianini
    Lira Filho, Edgar Bezerra
    Penha Tavares, Glaucia Maria
    Pfeferman, Abraham
    Pinho Makdisse, Marcia Regina
    Fischer, Claudio Henrique
    Morhy, Samira Saady
    EINSTEIN-SAO PAULO, 2008, 6 (04): : 445 - 451
  • [2] FACTORS INFLUENCING VALIDITY OF SYSTOLIC TIME INTERVALS IN ESTIMATING LEFT VENTRICULAR EJECTION FRACTION
    THOMAS, D
    BASTA, L
    KIOSCHOS, M
    CIRCULATION, 1972, 46 (04) : 230 - &
  • [3] Systolic time intervals in haemodialysis patients with normal ejection fraction:: An echocardiographic study
    Tükek, T
    Yildiz, A
    Akkaya, V
    Görçin, B
    Sever, MS
    Atilgan, D
    Korkut, F
    NEPHROLOGY, 2002, 7 (01) : 43 - 49
  • [4] Echocardiographic assessment of left ventricular systolic function: from ejection fraction to torsion
    Cameli, Matteo
    Mondillo, Sergio
    Solari, Marco
    Righini, Francesca Maria
    Andrei, Valentina
    Contaldi, Carla
    De Marco, Eugenia
    Di Mauro, Michele
    Esposito, Roberta
    Gallina, Sabina
    Montisci, Roberta
    Rossi, Andrea
    Galderisi, Maurizio
    Nistri, Stefano
    Agricola, Eustachio
    Mele, Donato
    HEART FAILURE REVIEWS, 2016, 21 (01) : 77 - 94
  • [5] Echocardiographic assessment of left ventricular systolic function: from ejection fraction to torsion
    Matteo Cameli
    Sergio Mondillo
    Marco Solari
    Francesca Maria Righini
    Valentina Andrei
    Carla Contaldi
    Eugenia De Marco
    Michele Di Mauro
    Roberta Esposito
    Sabina Gallina
    Roberta Montisci
    Andrea Rossi
    Maurizio Galderisi
    Stefano Nistri
    Eustachio Agricola
    Donato Mele
    Heart Failure Reviews, 2016, 21 : 77 - 94
  • [6] Overweight and obesity impair left ventricular systolic function as measured by left ventricular ejection fraction and global longitudinal strain
    Blomstrand, Peter
    Sjoblom, Peter
    Nilsson, Mats
    Wijkman, Magnus
    Engvall, Martin
    Lanne, Toste
    Nystrom, Fredrik H.
    Ostgren, Carl Johan
    Engvall, Jan
    CARDIOVASCULAR DIABETOLOGY, 2018, 17
  • [7] Overweight and obesity impair left ventricular systolic function as measured by left ventricular ejection fraction and global longitudinal strain
    Peter Blomstrand
    Peter Sjöblom
    Mats Nilsson
    Magnus Wijkman
    Martin Engvall
    Toste Länne
    Fredrik H. Nyström
    Carl Johan Östgren
    Jan Engvall
    Cardiovascular Diabetology, 17
  • [8] ADVANTAGES OF SYSTOLIC-TIME INTERVALS OVER ECHOCARDIOGRAPHY IN THE MEASUREMENT OF LEFT-VENTRICULAR EJECTION FRACTION
    ADENLE, B
    WEIR, EK
    CHESLER, E
    MINNESOTA MEDICINE, 1981, 64 (08) : 479 - 483
  • [9] Two-dimensional longitudinal strain for the assessment of the left ventricular systolic function as compared with conventional echocardiographic methods in patients with acute coronary syndromes
    Ryczek, Robert
    Krzesinski, Pawel
    Krzywicki, Pawel
    Smurzynski, Pawel
    Cwetsch, Andrzej
    KARDIOLOGIA POLSKA, 2011, 69 (04) : 357 - 363
  • [10] Real-time three dimensional echocardiographic left ventricular systolic evaluation: comparison between dyssynchrony indexes and ejection fraction
    Vieira, M. L. C.
    Gimenes, V. M. L.
    Oliveira, W. A.
    Naccarato, G.
    Cury, A.
    Pinheiro, J., Jr.
    Andrade, M. M.
    Pedra, S. F. P.
    Fischer, C. H.
    Morhy, S. S.
    CIRCULATION, 2008, 118 (12) : E451 - E452