Evaluation of the effect of tolterodine on pupil diameter and anterior chamber parameters with the Pentacam

被引:1
|
作者
Goktas, Altan [1 ]
机构
[1] Training & Res Hosp, Dept Ophthalmol, Kayseri, Turkey
关键词
Anterior chamber structures; anterior chamber parameters; Pentacam; pupil; tolterodine; BLADDER;
D O I
10.3109/15569527.2010.523036
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Methods: aEuro,The 56 eyes of 28 patients who were diagnosed as having overactive bladder and planned to be treated with tolterodine were followed up prospectively in the study. All the patients underwent full ophthalmic examination and scanning with the Pentacam (Oculus, Inc., Wetzlar, Germany) before and 4 weeks after the start date of tolterodine therapy. In addition, the 30 eyes of 15 healthy volunteers were analyzed twice as a control group for repeatability of the measurements. Results: aEuro,The quantitative descriptors of the anterior chamber before and after the treatment, respectively, were as follows: pupil diameter, 3.02 +/-+/- 0.56 mm and 3.01 +/-+/- 0.55 mm; anterior chamber depth, 2.74 +/-+/- 0.35 mm and 2.75 +/-+/- 0.34 mm; anterior chamber volume, 150.23 +/-+/- 33.95 mm<SU3</SU and 150.27 +/-+/- 34.48 mm<SU3</SU; and anterior chamber angle, 34.56 degrees A degrees +/-+/- 5.68 degrees A degrees and 35.03 degrees A degrees +/-+/- 5.99 degrees A degrees. For all the measurements, the differences did not reach statistical significance (p > .05). Also, the comparison of the same parameters obtained from the first and second measurements of healthy volunteers was not statistically significant (p > .05). Conclusion: aEuro,Our study demonstrates that tolterodine does not affect pupil diameter and anterior chamber parameters, including angle, volume, and depth. Most likely, it is an organ-selective agent, inhibiting muscarinic receptors in the bladder rather than in the anterior segment of the eye.
引用
收藏
页码:61 / 63
页数:3
相关论文
共 50 条
  • [1] Evaluation of the Effects of Menstrual Cycle on Anterior Chamber Parameters as Measured with Pentacam
    Karatepe, Arzu Seyhan
    Onay, Melis Palamar
    Egrilmez, Sait
    Yagci, Ayse
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2013, 43 (01): : 15 - 18
  • [2] Central Corneal Thickness, Anterior Chamber Depth, and Pupil Diameter Measurements Using Visante OCT, Orbscan, and Pentacam
    Yazici, Ahmet Taylan
    Bozkurt, Ercument
    Alagoz, Cengiz
    Alagoz, Nese
    Pekel, Gokhan
    Kaya, Vedat
    Yilmaz, Omer Faruk
    JOURNAL OF REFRACTIVE SURGERY, 2010, 26 (02) : 127 - 133
  • [3] Biometric Evaluation of Anterior Chamber Changes after Physiologic Pupil Dilation Using Pentacam and Anterior Segment Optical Coherence Tomography
    Aptel, Florent
    Chiquet, Christophe
    Beccat, Sylvain
    Denis, Philippe
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (07) : 4005 - 4010
  • [4] Evaluation of Cornea and Anterior Chamber with Pentacam in Scleroderma Cases
    Palamar, Melis
    Karatepe, Arzu Seyhan
    Egrilmez, Sait
    Yagci, Ayse
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2011, 41 (04): : 221 - 224
  • [5] Evaluation of Cornea and Anterior Chamber Using Pentacam in Pediatric Cases
    Onay, Melis Palamar
    Egrilmez, Salt
    Uretmen, Onder
    Yagci, Ayse
    Kose, Suheyla
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2011, 41 (03): : 133 - 137
  • [6] Evaluation of anterior chamber morphology following scleral buckling with Pentacam
    Zhu, Kai
    Li, Xiaojun
    Zhou, Enliang
    Zhang, Wei
    Zhang, Rui
    Gu, Yonghao
    PHOTODIAGNOSIS AND PHOTODYNAMIC THERAPY, 2023, 44
  • [7] Pentacam anterior chamber parameters in young and middle-aged Chinese
    Lam, Andrew K. C.
    Tse, Jimmy S. H.
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2013, 96 (01) : 85 - 91
  • [8] The Alterations of the Anterior Chamber Parameters Measured with Pentacam with Age in Healthy Subjects
    Emre, Sinan
    Koc, Bekir
    Doganay, Selim
    Yologlu, Saim
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2008, 38 (06): : 452 - 458
  • [9] EFFECT OF PUPIL DILATION AND CONSTRICTION ON ANTERIOR CHAMBER DEPTH
    Curchin, James
    Ong, Keith
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2018, 46 : 111 - 112
  • [10] Quantitative evaluation of anterior chamber changes after iridotomy using Pentacam anterior segment analyzer
    Lopez-Caballero, Cristina
    Puerto-Hernandez, Beatriz
    Munoz-Negrete, Francisco J.
    Rebolleda, Gema
    Contreras, Ines
    Cabarga, Carmen
    Corral, Angeles
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2010, 20 (02) : 327 - 332