The effect of calibration equations on the uncertainty of UV-Vis spectrophotometric measurements

被引:24
|
作者
Hsu, Kang-Hung [1 ]
Chen, Chiachung [1 ]
机构
[1] Natl Chung Hsing Univ, Dept Bioind Mechatron Engn, Taichung 40227, Taiwan
关键词
Uncertainty; Calibration equation; Nonlinearity; UV-Vis spectrophotometer;
D O I
10.1016/j.measurement.2010.08.021
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The effect of adequateness of the calibration equations on measurement uncertainty was not mentioned by EURACHEM. In this work, we investigate the sources of uncertainty when measuring glucose concentration with a UV-Vis spectrophotometer. The effect of two calibration equations on the uncertainty was compared. The sources of the glucose concentration measurement uncertainty include purity, volume of flasks, mass and the calibration equations. The effects of two calibration equations, linear and polynomial equation, on the uncertainty source were evaluated using the inverse calibration equation. The results indicated that the uncertainty components from purity were the smallest. The volumes of the volumetric flasks had only modest effect on the uncertainty, while the mass was an important source of the uncertainty. The contribution of the calibration equation to the total relative measurement uncertainty was 59.39% for the linear equation and 30.34% for the polynomial equation. With the selection of the adequate equation, the uncertainty source of the calibration equation could be reduced significantly. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1525 / 1531
页数:7
相关论文
共 50 条
  • [1] Uncertainty sources in UV-Vis spectrophotometric measurement
    Lilli Sooväli
    Eva-Ingrid Rõõm
    Agnes Kütt
    Ivari Kaljurand
    Ivo Leito
    [J]. Accreditation and Quality Assurance, 2006, 11 : 246 - 255
  • [2] Uncertainty sources in UV-Vis spectrophotometric measurement
    Soovaeli, Lilli
    Room, Eva-Ingrid
    Kuett, Agnes
    Kaljurand, Ivari
    Leito, Ivo
    [J]. ACCREDITATION AND QUALITY ASSURANCE, 2006, 11 (05) : 246 - 255
  • [3] The uncertainty of UV-Vis spectrophotometric and FAAS analysis for the determination of iron in pharmaceutical products
    Jurgens, Jaana
    Paama, Lilli
    Leito, Ivo
    [J]. ACCREDITATION AND QUALITY ASSURANCE, 2007, 12 (11) : 593 - 601
  • [4] Reflectance measurements in UV-VIS spectroscopy
    Jungnickel, A
    [J]. AMERICAN LABORATORY, 2003, 35 (19) : 18 - 19
  • [5] Calibration and validation of UV-vis absorption spectrophotometers
    Richardson, AC
    Messman, JD
    [J]. BIOPHARM-THE TECHNOLOGY & BUSINESS OF BIOPHARMACEUTICALS, 1997, 10 (08): : 7 - 7
  • [6] Calibration of UV-vis spectrophotometers for chemical analysis
    Clare, JF
    [J]. ACCREDITATION AND QUALITY ASSURANCE, 2005, 10 (06) : 283 - 288
  • [7] A new method for the absolute radiance calibration for UV-vis measurements of scattered sunlight
    Wagner, T.
    Beirle, S.
    Doerner, S.
    de Vries, M. Penning
    Remmers, J.
    Rozanov, A.
    Shaiganfar, R.
    [J]. ATMOSPHERIC MEASUREMENT TECHNIQUES, 2015, 8 (10) : 4265 - 4280
  • [8] The influence of the temperature in the UV-Vis spectrophotometers calibration
    Medina Marquez, J.
    Carranza Gallardo, J.
    [J]. 22ND CONGRESS OF THE INTERNATIONAL COMMISSION FOR OPTICS: LIGHT FOR THE DEVELOPMENT OF THE WORLD, 2011, 8011
  • [9] Curve fitting and linearization of UV-Vis spectrophotometric measurements to estimate yeast in inoculum preparation
    Carvalho, Anderson Ramos
    Genz Bazana, Luana Candice
    Ferrao, Marco Flores
    Fuentefria, Alexandre Meneghello
    [J]. ANALYTICAL BIOCHEMISTRY, 2021, 625
  • [10] The influence of local calibration on the quality of UV-VIS spectrometer measurements in urban stormwater monitoring
    Caradot, N.
    Sonnenberg, H.
    Riechel, M.
    Matzinger, A.
    Rouault, P.
    [J]. WATER PRACTICE AND TECHNOLOGY, 2013, 8 (3-4): : 417 - 424