Large area X-ray detectors for cargo radiography

被引:2
|
作者
Bueno, C. [1 ]
Albagli, D. [1 ]
Bendahan, J. [2 ]
Castleberry, D. [1 ]
Gordon, T. [1 ]
Hopkins, F. [1 ]
Ross, W. [1 ]
机构
[1] GE Global Res, One Res Circle, Niskayuna, NY 12309 USA
[2] GE Homeland Protect, Newark, CA 94560 USA
关键词
metal radiators; high-energy flat panel detectors; amorphous silicon diodes; Gd2O2S : Tb;
D O I
10.1117/12.736076
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Large area x-ray detectors based on phosphors coupled to flat panel amorphous silicon diode technology offer significant advances for cargo radiologic imaging. Flat panel area detectors provide large object coverage offering high throughput inspections to meet the high flow rate of container commerce. These detectors provide excellent spatial resolution when needed, and enhanced SNR through low noise electronics. If the resolution is reduced through pixel binning, further advances in SNR are achievable. Extended exposure imaging and frame averaging enables improved x-ray penetration of ultra-thick objects, or "select-your-own" contrast sensitivity at a rate many times faster than LDAs. The areal coverage of flat panel technology provides inherent volumetric imaging with the appropriate scanning methods. Flat panel area detectors have flexible designs in terms of electronic control, scintillator selection, pixel pitch, and frame rates. Their cost is becoming more competitive as production ramps up for the healthcare, nondestructive testing (NDT), and homeland protection industries. Typically used medical and industrial polycrystalline phosphor materials such as Gd2O2S:Tb (GOS) can be applied to megavolt applications if the phosphor layer is sufficiently thick to enhance x-ray absorption, and if a metal radiator is used to augment the quantum detection efficiency and reduce x-ray scatter. Phosphor layers ranging from 0.2-mm to 1-mm can be "sandwiched" between amorphous silicon flat panel diode arrays and metal radiators. Metal plates consisting of W, Pb or Cu, with thicknesses ranging from 0.25-mm to well over 1-min can be used by covering the entire area of the phosphor plate. In some combinations of high density metal and phosphor layers, the metal plate provides an intensification of 25% in signal due to electron emission from the plate and subsequent excitation within the phosphor material. This further improves the SNR of the system.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] X-ray detectors for digital radiography
    Yaffe, MJ
    Rowlands, JA
    PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (01): : 1 - 39
  • [2] APPLICATIONS OF X-RAY AREA DETECTORS
    ARNDT, UW
    ACTA CRYSTALLOGRAPHICA SECTION A, 1984, 40 : C405 - C405
  • [3] AREA DETECTORS FOR X-RAY SPECTROSCOPY
    CALLCOTT, TA
    TSANG, KL
    ZHANG, CH
    EDERER, DL
    ARAKAWA, ET
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 266 (1-3): : 578 - 585
  • [4] X-RAY TELEVISION AREA DETECTORS
    ARNDT, UW
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 201 (01): : 13 - 20
  • [5] Digital x-ray detectors for radiography: Technical innovations
    Dobbins, JT
    RADIOLOGY, 1999, 213P : 149 - 149
  • [6] Comparison of semiconductor radiation detectors for large area X-ray imaging
    Chi-Won, Choi
    Ji-Koon, Park
    Sang-Sik, Kang
    Sung-Ho, Cho
    Kyung-Jin, Kim
    Sung-Kwang, Park
    Heung-Kook, Choi
    Jae-Hyung, Kim
    Sang-Hee, Nam
    ADVANCES IN NANOMATERIALS AND PROCESSING, PTS 1 AND 2, 2007, 124-126 : 123 - 126
  • [7] Silicon-based large-area X-ray detectors
    Kaaret, P
    X-RAY TIMING 2003: ROSSI AND BEYOND, 2004, 714 : 423 - 430
  • [8] Large area X-ray detectors based on amorphous silicon technology
    Moy, JP
    THIN SOLID FILMS, 1999, 337 (1-2) : 213 - 221
  • [9] X-RAY PHOTOCATHODES FOR IMAGE INTENSIFIERS AND LARGE AREA THICK WINDOW DETECTORS
    ALEXANDROPOULOS, NG
    NUCLEAR INSTRUMENTS & METHODS, 1976, 137 (01): : 49 - 56
  • [10] A diffraction effect in X-ray area detectors
    Gollwitzer, C. (christian.gollwitzer@ptb.de), 1600, International Union of Crystallography, 5 Abbey Road, Chester, CH1 2HU, United Kingdom (47):