Risk factors for complications in cancer patients with totally implantable access ports: A retrospective study and review of the literature

被引:5
|
作者
Bademler, Suleyman [1 ]
Ucuncu, Muhammed [2 ]
Yildirim, Ilknur [3 ]
Karanlik, Hasan [4 ]
机构
[1] Istanbul Univ, Dept Gen Surg, Fac Med, Istanbul, Turkey
[2] Istanbul Gelisim Univ, Inst Hlth Sci, Istanbul, Turkey
[3] Istanbul Univ, Inst Oncol, Dept Anesthesiol, Istanbul, Turkey
[4] Istanbul Univ, Inst Oncol, Dept Gen Surg, Istanbul, Turkey
关键词
Cancer treatment; totally implantable access port; catheterization; complication; percutaneous intervention; ultrasound guidance; CENTRAL VENOUS CATHETERS; BLOOD-STREAM INFECTION; INTERNAL JUGULAR-VEIN; CHEMOTHERAPY; ULTRASOUND; DEVICES;
D O I
10.1177/0300060518808167
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objectives To analyze the risk factors for complications associated with the use of totally implantable access ports (TIAPs) in cancer patients. Methods Data for 2,713 cancer patients who received a TIAP between January 2010 and September 2016 at a single center were analyzed retrospectively. Results The average age of the patients was 54.2 +/- 9.92 years, and 1,247 (47.5%) were women. The right subclavian vein was the preferred insertion site. Seventy-seven patients developed early complications and 50 developed late complications. The incidence of complications increased as the number of punctures increased. Percutaneous intervention increased the risk of complications during port insertion, but age, sex, body mass index, and the use of physiological saline solution instead of heparin for washing after port insertion did not increase the risk. The use of ultrasonography during insertion reduced the risk of complications. Conclusions Various factors may affect the function of TIAPs in cancer patients both during insertion and follow-up. Age, sex, body mass index, and the use of physiological saline solution for washing did not affect the incidence of complications, but the use of ultrasonography during insertion did affect the complication rate.
引用
收藏
页码:702 / 709
页数:8
相关论文
共 50 条
  • [1] Late complications of totally implantable venous access ports in patients with cancer Risk factors and related nursing strategies
    Yu, Xin-Yan
    Xu, Jia-Lan
    Li, Dan
    Jiang, Zi-Fang
    MEDICINE, 2018, 97 (38)
  • [2] Totally implantable venous access ports: Retrospective review of long-term complications in 81 patients
    Bassi, K. K.
    Giri, A. K.
    Pattanayak, M.
    Abraham, S. W.
    Pandey, K. K.
    INDIAN JOURNAL OF CANCER, 2012, 49 (01) : 114 - 118
  • [3] Incidence of and risk factors for totally implantable vascular access device complications in patients with gastric cancer: A retrospective analysis
    Okazaki, Mitsuyoshi
    Oyama, Katsunobu
    Kinoshita, Jun
    Miyashita, Tomoharu
    Tajima, Hidehiro
    Takamura, Hiroyuki
    Ninomiya, Itasu
    Fushida, Sachio
    Ohta, Tetsuo
    MOLECULAR AND CLINICAL ONCOLOGY, 2019, 11 (04) : 343 - 348
  • [4] Complications and Risk Factors of Infection in Pediatric Hemato-Oncology Patients With Totally Implantable Access Ports (TIAPs)
    Nam, So-Hyun
    Kim, Dae-Yeon
    Kim, Seong-Chul
    Kim, In-Koo
    PEDIATRIC BLOOD & CANCER, 2010, 54 (04) : 546 - 551
  • [5] Risk factors for totally implantable access ports-associated thrombosis in pediatric oncology patients
    Yingxia Lan
    Liuhong Wu
    Jin Guo
    Juan Wang
    Huijie Guan
    Baihui Li
    Longzhen Liu
    Lian Zhang
    Ye Hong
    Jun Deng
    Jia Zhu
    Suying Lu
    Feifei Sun
    Junting Huang
    Xiaofei Sun
    Yizhuo Zhang
    Jian Wang
    Ruiqing Cai
    Scientific Reports, 13
  • [6] Risk factors for totally implantable access ports-associated thrombosis in pediatric oncology patients
    Lan, Yingxia
    Wu, Liuhong
    Guo, Jin
    Wang, Juan
    Guan, Huijie
    Li, Baihui
    Liu, Longzhen
    Zhang, Lian
    Hong, Ye
    Deng, Jun
    Zhu, Jia
    Lu, Suying
    Sun, Feifei
    Huang, Junting
    Sun, Xiaofei
    Zhang, Yizhuo
    Wang, Jian
    Cai, Ruiqing
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [7] Risk factors of infection of totally implantable venous access port: A retrospective study
    Guan, Xiaonan
    Yan, He
    Zhang, Jianjun
    Li, Yanbing
    Zhou, Yiming
    JOURNAL OF VASCULAR ACCESS, 2023, 24 (06): : 1340 - 1348
  • [8] Utility of totally implantable venous access ports in patients with breast cancer
    Zhang, Peng
    Du, Jun
    Fan, Changsheng
    Mo, Xueli
    Dong, Jie
    Fan, Zhenhua
    Zhao, Qikang
    BREAST JOURNAL, 2020, 26 (02): : 333 - 334
  • [9] A retrospective observational study on maintenance and complications of totally implantable venous access ports in 563 patients:Prolonged versus short flushing intervals
    Yuejiao Zhang
    Ruiyi Zhao
    Nan Jiang
    Yun Shi
    Qianmi Wang
    Ye Sheng
    InternationalJournalofNursingSciences, 2021, 8 (03) : 252 - 256
  • [10] A retrospective observational study on maintenance and complications of totally implantable venous access ports in 563 patients: Prolonged versus short flushing intervals
    Zhang, Yuejiao
    Zhao, Ruiyi
    Jiang, Nan
    Shi, Yun
    Wang, Qianmi
    Sheng, Ye
    INTERNATIONAL JOURNAL OF NURSING SCIENCES, 2021, 8 (03) : 252 - 256