PlasmaKinetic™ (bipolar) transurethral resection of prostate: a prospective trial to study pathological artefacts, surgical parameters and clinical outcomes

被引:0
|
作者
Poh, B. K. [1 ]
Mancer, K.
Goh, D. [1 ]
Lim, T. [1 ]
Ng, V
Ng, K. K. [1 ]
Ng, F. C. [1 ]
机构
[1] Changi Gen Hosp, Dept Urol, Singapore 529889, Singapore
关键词
bipolar; cautery artefacts; monopolar; PlasmaKinetic (TM); transurethral resection of prostate;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: The aims of the study were to compare the degree of cautery artefacts in prostatic chips between monopolar and PlasmaKinetic (TM) transurethral resection of prostate (TURP), and to determine if there is any difference in the intraoperative and post surgical parameters between them. Methods: After institutional review board approval, patients were prospectively enrolled to undergo PlasmaKinetic (TM) TURP. Their parameters were compared with those of the historical monopolar TURP controls. All histological specimens were reviewed by a single senior pathologist. Results: 46 patients were recruited to undergo PlasmaKinetic (TM) TURP. The resection time was significantly longer for the bipolar group compared to the monopolar group (50.2 versus 36.7 min, p-value is 0.001). The speed of resection (resection weight/time) was lower for the bipolar group (0.45 versus 0.56 g/min, p-value is 0.017). More irrigant was used for the bipolar group (21.2 versus 15.6 litres, p-value is 0.001) intraoperatively. There was no statistically significant difference in terms of intraoperative drop in haemoglobin and serum sodium change between the two groups. There seems to be a lesser degree of cautery artefacts in the PlasmaKinetic (TM) group than the monopolar group (42.17 versus 45.07 microns); however, this was not statistically significant (p-value is 0.452). Conclusion: Bipolar TURP seems to result in a lesser degree of cautery artefacts when compared to conventional monopolar TURP, albeit statistically insignificant, compared to monopolar TURP. TURP also resulted in a longer resection time and increased irrigant use, but no difference in blood loss and serum sodium levels.
引用
收藏
页码:336 / 339
页数:4
相关论文
共 50 条
  • [1] Four-Year Outcome of a Prospective Randomised Trial Comparing Bipolar Plasmakinetic and Monopolar Transurethral Resection of the Prostate
    Autorino, Riccardo
    Damiano, Rocco
    Di Lorenzo, Giuseppe
    Quarto, Giuseppe
    Perdona, Sisto
    D'Armiento, Massimo
    De Sio, Marco
    EUROPEAN UROLOGY, 2009, 55 (04) : 922 - 931
  • [2] Comparison of transurethral prostate resection and plasmakinetic prostate resection according to cautery artefacts in tissue specimens
    Akguel, K. Turgay
    Ayyildiz, Ali
    Nuhoglu, Baris
    Caydere, Muzaffer
    Uestuen, Hueseyin
    Germiyanoglu, Cankon
    INTERNATIONAL UROLOGY AND NEPHROLOGY, 2007, 39 (04) : 1091 - 1096
  • [3] Comparison of transurethral prostate resection and plasmakinetic prostate resection according to cautery artefacts in tissue specimens
    K. Turgay Akgül
    Ali Ayyıldız
    Barış Nuhoğlu
    Muzaffer Çaydere
    Hüseyin Üstün
    Cankon Germiyanoğlu
    International Urology and Nephrology, 2007, 39 : 1091 - 1096
  • [4] Comparative Study of the Effectiveness and Safety of Transurethral Bipolar Plasmakinetic Enucleation of the Prostate and Transurethral Bipolar Plasmakinetic Resection of the Prostate for Massive Benign Prostate Hyperplasia (>80 ml)
    Jiang, Yumei
    Bai, Xiaojing
    Zhang, Xinwei
    Wang, Meiyu
    Tian, Juanhua
    Mu, Lijun
    Zhang, Na
    Li, Man
    Du, Yuefeng
    MEDICAL SCIENCE MONITOR, 2020, 26
  • [6] Transurethral resection of prostate with plasmakinetic energy: 100 months results of a prospective randomized trial
    Muslumanoglu, Ahmet Y.
    Yuruk, Emrah
    Binbay, Murat
    Akman, Tolga
    BJU INTERNATIONAL, 2012, 110 (04) : 546 - 549
  • [7] Four-Year Outcome of a Prospective Randomised Trial Comparing Bipolar Plasmakinetic and Monopolar Transurethral Resection of the Prostate Editorial Comment
    Kaplan, Steven A.
    JOURNAL OF UROLOGY, 2010, 183 (05): : 1936 - 1936
  • [8] The effect of immediate surgical bipolar plasmakinetic transurethral resection of the prostate on prostatic hyperplasia with acute urinary retention
    He, Le-Ye
    Zhang, Yi-Chuan
    He, Jing-Liang
    Li, Liu-Xun
    Wang, Yong
    Tang, Jin
    Tan, Jing
    Zhong, Kuangbaio
    Tang, Yu-Xin
    Long, Zhi
    ASIAN JOURNAL OF ANDROLOGY, 2016, 18 (01) : 134 - 139
  • [9] Day Surgery Bipolar Plasmakinetic Transurethral Resection of the Prostate (pk-TURP): A 5-Year Prospective Study
    Tsang, W.
    Chua, W.
    Consigliere, D.
    UROLOGY, 2012, 80 (03) : S7 - S8
  • [10] A prospective randomized controlled trial comparing efficacy of hybrid bipolar transurethral vaporization and resection of prostate with bipolar transurethral resection of prostate (TURP)
    Chau, K. F.
    Yee, C. H.
    Chan, C. K.
    Chan, Eddie S. Y.
    Hou, S. M.
    Ng, C. F.
    BJU INTERNATIONAL, 2014, 113 : 13 - 13