Utilization of the lower inflection point of the pressure-volume curve results in protective conventional ventilation comparable to high frequency oscillatory ventilation in an animal model of acute respiratory distress syndrome

被引:3
|
作者
Rossi, Felipe S. [1 ]
Mascaretti, Renata Suman [1 ]
Haddad, Luciana B. [1 ]
Freddi, Norberto A. [1 ]
Mauad, Thais [2 ]
Rebello, Celso M. [1 ]
机构
[1] Univ Sao Paulo, Sch Med, Dept Pediat, Expt Res Unit LIM 30, Sao Paulo, Brazil
[2] Univ Sao Paulo, Sch Med, Dept Pathol, Sao Paulo, Brazil
关键词
acute respiratory distress syndrome; mechanical ventilation; ventilation induced lung injury; LIP; protective ventilation;
D O I
10.1590/S1807-59322008000200013
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
INTRODUCTION: Studies comparing high frequency oscillatory and conventional ventilation in acute respiratory distress syndrome have used low values of positive end-expiratory pressure and identified a need for better recruitment and pulmonary stability with high frequency. OBJECTIVE: To compare conventional and high frequency ventilation using the lower inflection point of the pressure-volume curve as the determinant of positive end-expiratory pressure to obtain similar levels of recruitment and alveolar stability. METHODS: After lung lavage of adult rabbits and lower inflection point determination, two groups were randomized: conventional (positive end-expiratory pressure = lower inflection point; tidal volume=6 ml/kg) and high frequency ventilation (mean airway pressures= lower inflection point +4 cmH(2)O). Blood gas and hemodynamic data were recorded over 4 h. After sacrifice, protein analysis from lung lavage and histologic evaluation were performed. RESULTS: The oxygenation parameters, protein and histological data were similar, except for the fact that significantly more normal alveoli were observed upon protective ventilation. High frequency ventilation led to lower PaCO2 levels. DISCUSSION: Determination of the lower inflection point of the pressure-volume curve is important for setting the minimum end expiratory pressure needed to keep the airways opened. This is useful when comparing different strategies to treat severe respiratory insufficiency, optimizing conventional ventilation, improving oxygenation and reducing lung injury. CONCLUSIONS: Utilization of the lower inflection point of the pressure-volume curve in the ventilation strategies considered in this study resulted in comparable efficacy with regards to oxygenation and hemodynamics, a high PaCO2 level and a lower pH. In addition, a greater number of normal alveoli were found after protective conventional ventilation in an animal model of acute respiratory distress syndrome.
引用
收藏
页码:237 / 244
页数:8
相关论文
共 50 条
  • [1] High-frequency oscillatory ventilation versus conventional ventilation for acute respiratory distress syndrome
    Sud, Sachin
    Sud, Maneesh
    Friedrich, Jan O.
    Wunsch, Hannah
    Meade, Maureen O.
    Ferguson, Niall D.
    Adhikari, Neill K. J.
    [J]. COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2016, (04):
  • [2] High-Frequency Oscillatory Ventilation Combined with Volume Guarantee in a Neonatal Animal Model of Respiratory Distress Syndrome
    Sanchez Luna, Manuel
    Santos Gonzalez, Martin
    Tendillo Cortijo, Francisco
    [J]. CRITICAL CARE RESEARCH AND PRACTICE, 2013, 2013
  • [3] The role of high frequency oscillatory ventilation in acute respiratory distress syndrome
    Gubran, Christopher
    Braganza-Menezes, Darryl
    [J]. THORAX, 2013, 68 (05) : 467 - 467
  • [4] High-frequency oscillatory ventilation for acute respiratory distress syndrome
    Dincer Yildizdas
    Hacer Yapicioglu
    Ibrahim Bayram
    Levent Yilmaz
    Yasar Sertdemir
    [J]. The Indian Journal of Pediatrics, 2009, 76 : 921 - 927
  • [5] High-frequency oscillatory ventilation for acute respiratory distress syndrome
    Yildizdas, Dincer
    Yapicioglu, Hacer
    Bayram, Ibrahim
    Yilmaz, Levent
    Sertdemir, Yasar
    [J]. INDIAN JOURNAL OF PEDIATRICS, 2009, 76 (09): : 921 - 927
  • [6] High frequency oscillatory ventilation in patients with acute respiratory distress syndrome
    Andersen, FA
    Guttormsen, AB
    Flaatten, HK
    [J]. INTENSIVE CARE MEDICINE, 2002, 28 : S141 - S141
  • [7] Body Mass Index And Outcome In Patients With Acute Respiratory Distress Syndrome Ventilated By High Frequency Oscillatory Ventilation Or Conventional Ventilation
    Tlayjeh, H.
    Arabi, Y. M.
    Ferguson, N. D.
    Lamontagne, F.
    Arroliga, A. C.
    Danesh, V.
    Dominguez-Cherit, G.
    Jimenez, E.
    Mullaly, A.
    Staub, B.
    Meade, M. O.
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2017, 195
  • [8] High frequency oscillatory ventilation versus conventional mechanical ventilation in pediatric acute respiratory distress syndrome: A randomized controlled study
    El-Nawawy, Ahmed
    Moustafa, Azza
    Heshmat, Hassan
    Abouahmed, Ahmed
    [J]. TURKISH JOURNAL OF PEDIATRICS, 2017, 59 (02) : 130 - 143
  • [9] High-frequency oscillatory ventilation for trauma patients with acute respiratory distress syndrome who fail conventional mechanical ventilation
    F Eng
    M Ferri
    S Rizoli
    L Tremblay
    [J]. Critical Care, 11 (Suppl 2):
  • [10] High frequency oscillatory ventilation in burn patients with the acute respiratory distress syndrome
    Cartotto, R
    Ellis, S
    Gomez, M
    Cooper, A
    Smith, T
    [J]. BURNS, 2004, 30 (05) : 453 - 463