Laser Doppler velocimetry (LDV) and 3D phase-contrast magnetic resonance angiography (PC-MRA) velocity measurements: Validation in an anatomically accurate cerebral artery aneurysm model with steady flow

被引:32
|
作者
Hollnagel, Dorothea I. [1 ]
Summers, Paul E. [2 ]
Kollias, Spyros S. [3 ]
Poulikakos, Dimos [1 ]
机构
[1] ETH, Inst Energy Technol, LTNT, CH-8092 Zurich, Switzerland
[2] Univ Oxford, Radcliffe Infirm, Dept Neuroradiol, Oxford OX2 6HE, England
[3] Univ Zurich Hosp, Inst Neuroradiol, CH-8091 Zurich, Switzerland
关键词
phase mapping; velocity mapping comparison; magnetic resonance angiography (MRA); magnetic resonance imaging (MRI); cerebral aneurysm; laser Doppler velocimetry (LDV);
D O I
10.1002/jmri.21179
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To verify the accuracy of velocity mapping with three-dimensional (3D) phase-contrast magnetic resonance angiography (PC-MFA) for steady flow in a realistic model of a cerebral artery aneurysm at a 3T scanner. Materials and Methods: Steady flow through an original geometry model of a cerebral aneurysm was mapped at characteristic positions by state-of-the-art laser Doppler velocimetry (LDV) as well as 3D PC-MRA at 3T. The spatial distributions and local values of two velocity components obtained with these two measurement methods were compared. Results: The 3D PC-MRA velocity field distribution and mean velocity values exhibited only minor differences to compare to the LDV measurements in,straight artery regions for both main and secondary velocities. The differences increased in regions with disturbed flow and in cases where the measurement plane was not perpendicular to the main flow direction. Conclusion: 3D PC-MRA can Provide reliable measurements of velocity components of steady flow in small arteries. The accuracy of such measurements depends on the artery size and the measurement plane positioning.
引用
收藏
页码:1493 / 1505
页数:13
相关论文
共 8 条
  • [1] Comparative velocity investigations in cerebral arteries and aneurysms: 3D phase-contrast MR angiography, laser Doppler velocimetry and computational fluid dynamics
    Hollnagel, Dorothea I.
    Summers, Paul E.
    Poulikakos, Dimos
    Kollias, Spyros S.
    NMR IN BIOMEDICINE, 2009, 22 (08) : 795 - 808
  • [2] Evaluation of renal artery stenosis by 3D gadolinium angiography and phase-contrast flow measurements
    Schoenberg, SO
    Knopp, MV
    Bock, M
    Essig, M
    Hawighorst, H
    Allenberg, JR
    RADIOLOGY, 1997, 205 : 473 - 473
  • [3] MEASUREMENTS OF FLOW VELOCITY OF THE CAROTID ARTERIES WITH 3 POINT PHASE-CONTRAST MAGNETIC-RESONANCE ANGIOGRAPHY (PCMRA)
    MAKABE, T
    ASARI, S
    OHMOTO, T
    STROKE, 1994, 25 (03) : 754 - 754
  • [4] Doppler-Assessed Cerebral Blood Flow Velocity in the Neonate as Estimator of Global Cerebral Blood Volume Flow Measured Using Phase-Contrast Magnetic Resonance Angiography
    Benders, Manon J. N. L.
    Hendrikse, Jeroen
    de Vries, Linda
    Groenendaal, Floris
    van Bel, Frank
    NEONATOLOGY, 2013, 103 (01) : 21 - 26
  • [5] Cerebral blood flow volume measurements of the carotid artery and ipsilateral branches using two-dimensional phase-contrast magnetic resonance angiography
    Guo, Gang
    Yang, Yonggui
    Yang, Weiqun
    NEURAL REGENERATION RESEARCH, 2011, 6 (30) : 2367 - 2371
  • [7] Validation of magnetic resonance phase-contrast flow measurements in the main pulmonary artery and aorta using perivascular ultrasound in a large animal model
    Ley, Sebastian
    Unterhinninghofen, Roland
    Ley-Zaporozhan, Julia
    Schenk, Jens-Peter
    Kauczor, Hans-Ulrich
    Szabo, Gabor
    INVESTIGATIVE RADIOLOGY, 2008, 43 (06) : 421 - 426
  • [8] Velocity Measurements in the Middle Cerebral Arteries of Healthy Volunteers Using 3D Radial Phase-Contrast HYPRFlow: Comparison with Transcranial Doppler Sonography and 2D Phase-Contrast MR Imaging
    Chang, W.
    Landgraf, B.
    Johnson, K. M.
    Kecskemeti, S.
    Wu, Y.
    Velikina, J.
    Rowley, H.
    Wieben, O.
    Mistretta, C.
    Turski, P.