Effect of Cementless Acetabular Component Orientation, Position, and Containment in Total Hip Arthroplasty for Congenital Hip Disease

被引:48
|
作者
Georgiades, George [1 ]
Babis, George C. [2 ]
Kourlaba, Georgia [3 ]
Hartofilakidis, George [4 ]
机构
[1] Dept Tripoli Hosp, Athens 11525, Greece
[2] Univ Athens, Sch Med, Dept Orthoped 1, Athens 14576, Greece
[3] Harokopio Univ, Off Biostat, Athens 11528, Greece
[4] Univ Athens, Sch Med, Athens 11471, Greece
来源
JOURNAL OF ARTHROPLASTY | 2010年 / 25卷 / 07期
关键词
cementless acetabular component; position; orientation; containment; congenital hip disease; LOW-FRICTION ARTHROPLASTY; FOLLOW-UP; DEVELOPMENTAL DYSPLASIA; POLYETHYLENE WEAR; FEMORAL COMPONENTS; PELVIC OSTEOLYSIS; DISLOCATION; REPLACEMENT; PLACEMENT; ADULTS;
D O I
10.1016/j.arth.2009.12.016
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We evaluated the effect of the inclination angle, position, and containment of 53 cementless cups inserted in patients with congenital hip disease (CHD), after a minimum of 10 years of follow-up. The polyethylene wear rate was significantly greater when the cup was placed in more than 45 degrees inclination (P = .045) or if the cup was placed lateral to the teardrop position by more than 25 mm (P = .001). Aseptic loosening of the femoral component was significantly greater when the cup was placed more than 25 mm superiorly to the teardrop (P = .049). Cup placement of more than 25 mm lateral to the teardrop affected significantly periacetabular osteolysis (P = .032). In CHD cases, it is preferable to avoid excessive vertical inclination, lateral, and superior placement of cementless cups in an attempt to obtain better containment.
引用
收藏
页码:1143 / 1150
页数:8
相关论文
共 50 条
  • [1] CEMENTLESS FIXATION OF THE ACETABULAR COMPONENT IN TOTAL HIP-ARTHROPLASTY
    DEKLERK, AJ
    BOMBELLI, R
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1984, 66 (03): : 447 - 447
  • [2] Total hip arthroplasty with the use of nonmodular cementless acetabular component
    Kim, SY
    Kim, DH
    Oh, CW
    Kim, PT
    Ihn, JC
    Kim, SY
    [J]. JOURNAL OF ARTHROPLASTY, 2005, 20 (05): : 632 - 638
  • [3] Effect of acetabular cup position and orientation in cemented total hip arthroplasty
    Hirakawa, K
    Mitsugi, N
    Koshino, T
    Saito, T
    Hirasawa, Y
    Kubo, T
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2001, (388) : 135 - 142
  • [4] Effect of Pelvic Obliquity on the Orientation of the Acetabular Component in Total Hip Arthroplasty
    Zhou, Xiaoxiao
    Wang, Qi
    Zhang, Xianlong
    Chen, Yunshu
    Shen, Hao
    Jiang, Yao
    [J]. JOURNAL OF ARTHROPLASTY, 2012, 27 (02): : 299 - 304
  • [5] CEMENTLESS FIXATION OF POLYETHYLENE ACETABULAR COMPONENT IN TOTAL HIP-ARTHROPLASTY
    MORSCHER, EW
    DICK, W
    KERNEN, V
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1982, 99 (04) : 223 - 230
  • [6] Acetabular component orientation in total hip arthroplasty: the impact of obesity
    McArthur, Benjamin A.
    Vulcano, Ettore
    Cross, Michael
    Nguyen, Joseph
    Della Valle, Alejandro G.
    Salvati, Eduardo
    [J]. HIP INTERNATIONAL, 2014, 24 (03) : 263 - 269
  • [7] The influence of acetabular component position on wear in total hip arthroplasty
    Wan, Zhinian
    Boutary, Myriam
    Dorr, Lawrence D.
    [J]. JOURNAL OF ARTHROPLASTY, 2008, 23 (01): : 51 - 56
  • [8] Spinopelvic mobility and acetabular component position for total hip arthroplasty
    Stefl, M.
    Lundergan, W.
    Heckmann, N.
    McKnight, B.
    Ike, H.
    Murgai, R.
    Dorr, L. D.
    [J]. BONE & JOINT JOURNAL, 2017, 99B (01): : 37 - 45
  • [9] ACETABULAR COMPONENT ORIENTATION IN TOTAL HIP ARTHROPLASTY: THE ROLE OF ACETABULAR TRANSVERSE LIGAMENT
    El Idrissi, Mohammed
    Elibrahimi, Abdelhalim
    Shimi, Mohammed
    Elmrini, Abdelmajid
    [J]. Acta Ortopedica Brasileira, 2016, 24 (05): : 267 - 269
  • [10] Cementless total hip arthroplasty with a threaded acetabular cup
    Fernandez-Gonzalez, J
    Sevillano, RC
    Garcia-Araujo, C
    [J]. INTERNATIONAL ORTHOPAEDICS, 1997, 21 (05) : 327 - 331