Evaluation of T2-Weighted MRI for Visualization and Sparing of Urethra with MR-Guided Radiation Therapy (MRgRT) On-Board MRI

被引:10
|
作者
Pham, Jonathan [1 ,2 ]
Savjani, Ricky R. [2 ]
Gao, Yu [2 ]
Cao, Minsong [1 ,2 ]
Hu, Peng [1 ,3 ]
Sheng, Ke [1 ,2 ]
Low, Daniel A. [1 ,2 ]
Steinberg, Michael [2 ]
Kishan, Amar U. [2 ]
Yang, Yingli [1 ,2 ]
机构
[1] Univ Calif Los Angeles, Phys & Biol Med IDP, 650 Charles E Young Dr S, Los Angeles, CA 90095 USA
[2] Univ Calif Los Angeles, Dept Radiat Oncol, 200 Med Plaza Driveway, Los Angeles, CA 90095 USA
[3] Univ Calif Los Angeles, Dept Radiol, 300 Med Plaza Driveway, Los Angeles, CA 90095 USA
关键词
MR-guided radiation therapy (MRgRT); prostate cancer; urethra; genitourinary (GU) toxicity; treatment planning; contouring; PROSTATE; BRACHYTHERAPY;
D O I
10.3390/cancers13143564
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Simple Summary Stereotactic body radiation therapy (SBRT) has become a standard of care option for prostate cancer patients, utilizing large fractionated dose to shorten treatment times. However, genitourinary (GU) toxicity associated with urethral injury remains prevalent due to non-trivial urethra delineation and sparing at treatment planning and treatment delivery. The aim of our study was to evaluate two optimized urethral MRI sequences (3D HASTE and 3D TSE) with a 0.35T MR-guided radiotherapy (MRgRT) system for urethral visibility and delineation. Among 11 prostate cancer patients, a radiation oncologist qualitatively scored MRgRT 3D HASTE as having the best urethra visibility, superior to CT, clinical MRgRT 3D bSSFP, MRgRT 3D TSE, and similar to diagnostic 3T (2D/3D) T2-weighetd MRI. Moreover, urethra contours from different imaging and clinical workflows demonstrated significant urethra localization variability. Optimized 3D MRgRT HASTE can provide urethral visualization and delineation within an MRgRT workflow for urethral sparing, avoiding cross-modality/system registration errors. Purpose: To evaluate urethral contours from two optimized urethral MRI sequences with an MR-guided radiotherapy system (MRgRT). Methods: Eleven prostate cancer patients were scanned on a MRgRT system using optimized urethral 3D HASTE and 3D TSE. A resident radiation oncologist contoured the prostatic urethra on the patients' planning CT, diagnostic 3T T2w MRI, and both urethral MRIs. An attending radiation oncologist reviewed/edited the resident's contours and additionally contoured the prostatic urethra on the clinical planning MRgRT MRI (bSSFP). For each image, the resident radiation oncologist, attending radiation oncologist, and a senior medical physicist qualitatively scored the prostatic urethra visibility. Using MRgRT 3D HASTE-based contouring workflow as baseline, prostatic urethra contours drawn on CT, diagnostic MRI, clinical bSSFP and 3D TSE were evaluated relative to the contour on 3D HASTE using 95th percentile Hausdorff distance (HD95), mean-distance-to-agreement (MDA), and DICE coefficient. Additionally, prostatic urethra contrast-to-noise-ratios (CNR) were calculated for all images. Results: For two out of three observers, the urethra visibility score for 3D HASTE was significantly higher than CT, and clinical bSSFP, but was not significantly different from diagnostic MRI. The mean HD95/MDA/DICE values were 11.35 +/- 3.55 mm/5.77 +/- 2.69 mm/0.07 +/- 0.08 for CT, 7.62 +/- 2.75 mm/3.83 +/- 1.47 mm/0.12 +/- 0.10 for CT + diagnostic MRI, 5.49 +/- 2.32 mm/2.18 +/- 1.19 mm/0.35 +/- 0.19 for 3D TSE, and 6.34 +/- 2.89 mm/2.65 +/- 1.31 mm/0.21 +/- 0.12 for clinical bSSFP. The CNR for 3D HASTE was significantly higher than CT, diagnostic MRI, and clinical bSSFP, but was not significantly different from 3D TSE. Conclusion: The urethra's visibility scores showed optimized urethral MRgRT 3D HASTE was superior to the other tested methodologies. The prostatic urethra contours demonstrated significant variability from different imaging and workflows. Urethra contouring uncertainty introduced by cross-modality registration and sub-optimal imaging contrast may lead to significant treatment degradation when urethral sparing is implemented to minimize genitourinary toxicity.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Evaluation of T2-Weighted MRI Pulse Sequences for Visualization and Sparing of Urethra with MR-Guided Radiation Therapy (MRgRT) On-Board MRI
    Pham, J.
    Savjani, R.
    Gao, Y.
    Cao, M.
    Hu, P.
    Low, D.
    Steinberg, M.
    Kishan, A.
    Yang, Y.
    MEDICAL PHYSICS, 2020, 47 (06) : E616 - E616
  • [2] Fully Automated Segmentation of Prostatic Urethra for MR-Guided Radiation Therapy (MRgRT)
    Xu, D.
    Ma, T.
    Savjani, R.
    Cao, M.
    Yang, Y.
    Kishan, A.
    Scalzo, F.
    Sheng, K.
    MEDICAL PHYSICS, 2022, 49 (06) : E483 - E483
  • [3] GAN for synthesizing CT from T2-weighted MRI data towards MR-guided radiation treatment
    Ranjan, Amit
    Lalwani, Debanshu
    Misra, Rajiv
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2022, 35 (03) : 449 - 457
  • [4] GAN for synthesizing CT from T2-weighted MRI data towards MR-guided radiation treatment
    Amit Ranjan
    Debanshu Lalwani
    Rajiv Misra
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2022, 35 : 449 - 457
  • [5] On-board MRI image compression using video encoder for MR-guided radiotherapy
    Shang, Jiawen
    Huang, Peng
    Zhang, Ke
    Dai, Jianrong
    Yan, Hui
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (08) : 5207 - 5217
  • [6] Comparison of Motion-Insensitive T2-Weighted MRI Pulse Sequences for Visualization of the Prostatic Urethra During MR Simulation
    Zakian, Kristen L.
    Wibmer, Andreas
    Vargas, Hebert A.
    Alberts, Eveline
    Kadbi, Mo
    Mychalczak, Borys
    Kollmeier, Marisa
    Gorovets, Daniel
    McBride, Sean
    Hunt, Margie
    Zelefsky, Michael J.
    Tyagi, Neelam
    PRACTICAL RADIATION ONCOLOGY, 2019, 9 (06) : E534 - E540
  • [7] Ferumoxytol Relaxivity and Signal Enhancement for MR-Guided Radiation Therapy (MRgRT) at 0.35T: A Feasibility Study
    Pham, J.
    Colbert, C.
    Cao, M.
    Nguyen, K.
    Yang, Y.
    MEDICAL PHYSICS, 2022, 49 (06) : E422 - E422
  • [8] The Role of MRS in Radiation Therapy: Correlation Between T2-Weighted MRI, Biopsy and MRS
    Hossain, M.
    Chen, L.
    Buyyounouski, M.
    Milestone, B.
    Richardson, T.
    Ma, C.
    MEDICAL PHYSICS, 2008, 35 (06) : 2721 - +
  • [9] A neuropsychological, MR sprectroscopic and MR perfusion study ofsignal hyperintensities on T2-weighted MRI
    Sachdev, P
    Looi, J
    Wen, W
    Brodaty, H
    Valenzuela, M
    Lorentz, L
    Howard, L
    Jones, M
    Sims, J
    Shnier, R
    Zagami, A
    Gillies, D
    NEUROBIOLOGY OF AGING, 2002, 23 (01) : S363 - S363
  • [10] Evaluation of 3D T2-weighted Breast MRI
    Moran, C. J.
    Hargreaves, B. A.
    Saranathan, M.
    Daniel, B. L.
    CANCER RESEARCH, 2012, 72