Calibrated simulation for estimating energy savings by the use of cool roof in five Indian climatic zones

被引:32
|
作者
Bhatia, Aviruch [1 ]
Mathur, Jyotirmay [1 ]
Garg, Vishal [2 ]
机构
[1] Malaviya Natl Inst Technol, Dept Mech Engn, Jaipur 302017, Rajasthan, India
[2] Int Inst Informat Technol, Ctr IT Bldg Sci, Hyderabad 500032, Andhra Pradesh, India
关键词
BUILDING ENERGY; PERFORMANCE;
D O I
10.1063/1.3582768
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A calibrated model has been used to estimate the energy savings by cool roof application on buildings located in five different climatic zones. The model has been calibrated as per the measured data in a building located in Hyderabad (India), and the same has been used to project energy savings in different cities located in five different climatic zones of the country. Results show that the maximum reduction in energy consumption is observed in Mumbai (warm and humid climate), followed by Ahmedabad (hot and dry climate), Bangalore (temperate climate), and Delhi (composite climate). Least energy saving is observed in Shillong (cold climate). In all the climates except cold, the financial payback period is acceptable, being less than 3 yr, whereas for cold climate, the investment is getting paid back in 6.69 yr, making the cool roof application not very attractive. (C) 2011 American Institute of Physics. [doi: 10.1063/1.3582768]
引用
收藏
页数:14
相关论文
共 34 条
  • [1] Calibrated simulation analysis for integration of evaporative cooling and radiant cooling system for different Indian climatic zones
    Srivastava, Prateek
    Khan, Yasin
    Bhandari, Mahabir
    Mathur, Jyotirmay
    Pratap, Ranaveer
    JOURNAL OF BUILDING ENGINEERING, 2018, 19 : 561 - 572
  • [2] Demonstrated energy savings of cool roof coatings and future directions for research
    Gartland, Lisa
    Interface (Raleigh, North Carolina), 1997, 15 (11): : 8 - 10
  • [3] Simulation of the thermal behaviour of a building retrofitted with a green roof: optimization of energy efficiency with reference to italian climatic zones
    Gargari, Caterina
    Bibbiani, Carlo
    Fantozzi, Fabio
    Campiotti, Carlo Alberto
    FLORENCE 'SUSTAINABILITY OF WELL-BEING INTERNATIONAL FORUM', 2015: FOOD FOR SUSTAINABILITY AND NOT JUST FOOD, FLORENCESWIF2015, 2016, 8 : 628 - 636
  • [4] Correlation of Ventilative Cooling Potentials and Building Energy Savings in Various Climatic Zones
    Rahman, Haolia
    Han, Hwataik
    ENERGIES, 2019, 12 (06):
  • [5] Measured temperature reductions and energy savings from a cool tile roof on a central California home
    Rosado, Pablo J.
    Faulkner, David
    Sullivan, Douglas P.
    Levinson, Ronnen
    ENERGY AND BUILDINGS, 2014, 80 : 57 - 71
  • [6] A detailed investigation on thermal performance and energy savings of cool roof systems for composite climates of India
    Kulkarni, Kishor S.
    Singh, Garima
    Premi, Renu
    ADVANCES IN BUILDING ENERGY RESEARCH, 2024, 18 (05) : 453 - 474
  • [7] Energy and cost savings of cool coatings for multifamily buildings in U.S. climate zones
    Nie, Xiao
    Flores, Robert
    Brouwer, Jack
    Lee, Jaeho
    ADVANCES IN APPLIED ENERGY, 2024, 13
  • [8] Estimating Industrial Building Energy Savings using Inverse Simulation
    Sever, Franc
    Kissock, Kelly
    Brown, Dan
    Mulqueen, Steve
    ASHRAE: TRANSACTIONS 2011, VOL 117, PT 1, 2011, 117 : 348 - 355
  • [9] Estimates of cooling effect and energy savings for a cool white coating used on the roof of scale model buildings
    Qu, J.
    Guan, S.
    Qin, J.
    Zhang, W.
    Li, Y.
    Zhang, T.
    3RD INTERNATIONAL CONFERENCE ON NEW MATERIAL AND CHEMICAL INDUSTRY, 2019, 479
  • [10] Cool Roof Use in Commercial Buildings in the United States: An Energy Cost Analysis
    Taylor, Thomas J.
    Hartwig, Christian
    ASHRAE TRANSACTIONS, VOL 124, PT 1, 2018, 124 : 88 - 96