Postural control in the elderly:: An analysis of test-retest and interrater reliability of the COP-COM variable

被引:88
|
作者
Corriveau, H
Hébert, R
Prince, F
Raîche, M
机构
[1] Univ Ottawa, Sch Rehabil Sci, Ottawa, ON K1H 8M5, Canada
[2] Sherbrooke Geriatr Univ Inst, Gerontol & Geriatr Res Ctr, Sherbrooke, PQ, Canada
[3] Univ Montreal, Dept Kinesiol, Montreal, PQ, Canada
来源
基金
英国医学研究理事会;
关键词
accidental falls; aged; cerebrovascular accidents; diabetic neuropathics; posture; rehabilitation;
D O I
10.1053/apmr.2001.18678
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objectives: To estimate the test-retest and interrater reliability of the center of pressure-center of mass (COP-COM) variable of postural control in the elderly. Design: The biomechanic variable COP-COM, which represents the distance between the COP and the COM, was determined from 2 AMTI force platforms and 3 OPTOTRAK(T) position sensors. Measurements were taken in quiet position, double leg stance, and eyes open and eyes closed conditions. Setting: Laboratory environment. Participants: Forty-five healthy subjects, 8 patients with diabetes neuropathy, and 7 stroke survivors, all of whom were at least 60 years old. Interventions: Subjects were evaluated on 2 separate occasions within 7 days by the same evaluator to determine test-retest reliability. Interrater reliability was determined the same day. Main Outcome Measures: The biomechanic variable COP-COM, which represents the distance between the COP and the COM in terms of root mean square. The mean of 4 trials of the COP-COM variable for each condition was used for statistical analysis. Intraclass correlation coefficients (ICCs) were used. Results: The COP-COM variable has good reliability for both the test-retest and interrater studies, but its reliability varies according to the direction of the COP-COM. For the test-retest and interrater studies, the ICC ranged from .89 to .93 in the anteroposterior direction and from .74 to .79 in the mediolateral direction. Conclusion: The equivalence of the test-retest and interrater coefficients obtained suggests that the measurement error of the COP-COM variable is mainly linked to the biologic variability of this measure over a short period of time. Using the mean of 4 trials stabilizes the COP-COM variable enough to be potentially used to evaluate clinical change.
引用
收藏
页码:80 / 85
页数:6
相关论文
共 50 条
  • [1] Test-retest and interrater reliability of Barcelona test
    Serra-Mayoral, A.
    Pena-Casanova, J.
    [J]. NEUROLOGIA, 2006, 21 (06): : 277 - 281
  • [2] Test-Retest Reliability of Postural Control Assessment on Biodex BioSway™
    Miner, Daniel
    Harper, Brent A.
    Glass, Stephen
    Martin, Brooke
    Polizotto, Molly
    Hearl, S. Montana
    Turner, Ellen
    [J]. BIOMED RESEARCH INTERNATIONAL, 2022, 2022
  • [3] Test-Retest Reliability of Multiple Postural Control Assessment Measures
    Mormile, Megan E.
    Szekely, Brian J.
    Grimes, Katelyn E.
    Mizeski, Brian J.
    Munkasy, Barry A.
    Powell, Douglas W.
    Murray, Nicholas G.
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2017, 49 (05): : 314 - 314
  • [4] TEST-RETEST AND INTERRATER RELIABILITY OF A PROCESS SKILLS ASSESSMENT
    DOBLE, SE
    [J]. OCCUPATIONAL THERAPY JOURNAL OF RESEARCH, 1991, 11 (01): : 8 - 23
  • [5] Test-Retest and Interrater Reliability of the Functional Movement Screen
    Shultz, Rebecca
    Anderson, Scott C.
    Matheson, Gordon O.
    Marcello, Brandon
    Besier, Thor
    [J]. JOURNAL OF ATHLETIC TRAINING, 2013, 48 (03) : 331 - 336
  • [6] Interrater and test-retest reliability of the Hand Assessment for Infants
    Ullenhag, Anna
    Ek, Linda
    Eliasson, Ann-Christin
    Krumlinde-Sundholm, Lena
    [J]. DEVELOPMENTAL MEDICINE AND CHILD NEUROLOGY, 2021, 63 (12): : 1456 - 1461
  • [7] Interrater and test-retest reliability of a fixed condition Design Fluency Test
    Kingery, Lisle R.
    Schretlen, David J.
    Sateri, Sara
    Langley, Linda K.
    Marano, Nicole C.
    Meyer, Stephen M.
    [J]. CLINICAL NEUROPSYCHOLOGIST, 2006, 20 (04) : 729 - 740
  • [8] Test-Retest and Interrater Reliability of the Functional Lower Extremity Evaluation
    Haitz, Karyn
    Shultz, Rebecca
    Hodgins, Melissa
    Matheson, Gordon O.
    [J]. JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2014, 44 (12): : 947 - 954
  • [9] INTERRATER AND TEST-RETEST RELIABILITY OF 2 PEDIATRIC BALANCE TESTS
    ATWATER, SW
    CROWE, TK
    DEITZ, JC
    RICHARDSON, PK
    [J]. PHYSICAL THERAPY, 1990, 70 (02): : 79 - 87
  • [10] Interrater and Test-Retest Reliability of the Sensory Integration Clinical Observations
    May-Benson, Teresa