Improving sampling rate with multiplexed ultrasonic emitters

被引:0
|
作者
Hori, T
Nishida, Y
Kanade, T
Akiyama, K
机构
关键词
multiplexed ultrasonic emitters; multilateration; robust estimation; sensorized environments;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper presents a position estimation method for multiple ultrasonic emitters which are activated simultaneously. Locations of ultrasonic emitters are generally calculated from distance data obtained at receivers. but the emitters must be activated one after another to avoid crosstalk. Thus, the sampling rate for each emitter decreases as the number of emitters increases. The authors solved this problem by activating multiple emitters simultaneously and applying a newly developed position estimation algorithm. This paper presents the theoretical analysis and the results of simulations and experiments.
引用
收藏
页码:4522 / 4527
页数:6
相关论文
共 50 条
  • [1] Improving the Nyquist Rate for Complex Stationary Process Sampling
    Bernard Lacaze
    Sampling Theory in Signal and Image Processing, 2002, 1 (1): : 33 - 51
  • [2] Multiplexed electrospray emitters fabricated by rapid laser micromachining
    Li, Liurui
    Yang, Weiwei
    Zhao, Xinyan
    Deng, Weiwei
    Journal of Aerosol Science, 2020, 150
  • [3] Multiplexed electrospray emitters fabricated by rapid laser micromachining
    Li, Liurui
    Yang, Weiwei
    Zhao, Xinyan
    Deng, Weiwei
    JOURNAL OF AEROSOL SCIENCE, 2020, 150
  • [4] Ultrasonic signal compressive detection with sub-Nyquist sampling rate
    Zhuang, Xiaoyan
    Zhao, Yijiu
    Dai, Zhijian
    Wang, Houjun
    Wang, Li
    JOURNAL OF SCIENTIFIC & INDUSTRIAL RESEARCH, 2012, 71 (03): : 195 - 199
  • [5] Multiplexed interferometer for ultrasonic imaging applications
    Murray, TW
    Krishnaswamy, S
    OPTICAL ENGINEERING, 2001, 40 (07) : 1321 - 1328
  • [6] MULTIPLEXED ARRAYS FOR ULTRASONIC INSPECTION SYSTEMS
    MEYER, PA
    MILLER, CS
    CARODISKEY, TJ
    MATERIALS EVALUATION, 1984, 42 (10) : A28 - A28
  • [7] Hyperspectral Counting of Multiplexed Nanoparticle Emitters in Single Cells and Organelles
    Jena, Prakrit, V
    Gravely, Mitchell
    Cupo, Christian
    Safaee, Mohammad Moein
    Roxbury, Daniel
    Heller, Daniel A.
    ACS NANO, 2022, 16 (02) : 3092 - 3104
  • [8] High Sampling Rate Fiber-Optic Extensometry for Ultrasonic Wave Detection
    Garcia, C. E.
    Gueemes, J. A.
    Fernandez, A.
    STRUCTURAL HEALTH MONITORING 2011: CONDITION-BASED MAINTENANCE AND INTELLIGENT STRUCTURES, VOL 2, 2013, : 1620 - 1627
  • [9] Improving the measurement of the load signal through a more appropriate sampling rate
    Seneviratne, S
    Levy, D
    PDPTA '04: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON PARALLEL AND DISTRIBUTED PROCESSING TECHNIQUES AND APPLICATIONS, VOLS 1-3, 2004, : 756 - 762
  • [10] Sampling Rate Optimization for Improving the Cascaded Integrator Comb Filter Characteristics
    Amrane, Raouf
    Brik, Youcef
    Zeghlache, Samir
    Ladjal, Mohamed
    Chicouche, Djamel
    TRAITEMENT DU SIGNAL, 2021, 38 (01) : 97 - 103