Simultaneous Determination of Hydrocodone, and Its Two Metabolites in Human Plasma by HPLC-MS-MS

被引:4
|
作者
Hao, Guang-Tao [1 ]
Chen, Yan [2 ]
Dong, Rui-Hua [1 ]
Qu, Heng-Yan [1 ]
Liang, Yu-Guang [1 ]
Li, Yuan-Yuan [1 ]
Zheng, Zhuan-Jie [1 ]
Gao, Hong-Zhi [1 ]
Liu, Ze-Yuan [1 ]
机构
[1] Acad Mil Med Sci, Affiliated Hosp, Dept Pharmacol, Beijing 100071, Peoples R China
[2] Bejing Wellso Pharmaceut Co Ltd, Beijing 100081, Peoples R China
关键词
HPLC-MS-MS; Hydrocodone; Norhydrocodone; Hydromorphone; LIQUID-CHROMATOGRAPHY; HYDROMORPHONE; CODEINE;
D O I
10.1007/s10337-011-2118-z
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A rapid, sensitive and specific assay method has been developed to simultaneously determine human plasma concentrations of hydrocodone and its metabolites, norhydrocodone, hydromorphone, using high-performance liquid chromatography with an electrospray ionization (ESI) tandem mass spectrometry (HPLC-MS-MS). Hydrocodone, its metabolites, and internal standard, hydrocodone-d(3), norhydrocodone-d(3), hydromorphone-d(3), were separated from human plasma using solid-phase extraction (Empore MPC-SD Solid Phase Extraction Disk). The eluate was dried, reconstituted and injected into the LC-MS-MS system. Chromatographic separation was performed on a Kromasil 100-5SIL-Dimensions C-18 column (100 x 2.1 mm, 5.0 mu m, Thermo Hypersil-Keystone, USA) using a gradient mobile phase with 20 mmol L-1 ammonium formate in water with 0.2% formic acid and 0.1% formic acid in acetonitrile. Detection and quantitation were performed by MS/MS using electrospray ionization and multiple reactions monitoring in the positive ion mode. The calibration curves were linear over the concentration ranges 0.05-50 ng mL(-1) for hydrocodone (r(2) = 0.9991) and norhydrocodone (r(2) = 0.9990), and 0.01-10 ng mL(-1) for hydromorphone (r(2) = 0.9990). The limit of quantification was 0.05 ng mL(-1) for hydrocodone and norhydrocodone, and 0.01 ng mL(-1) for hydromorphone. The extraction recovery was above 64.36, 68.51 and 71.78% for hydrocodone, norhydrocodone and hydromorphone. The accuracy was higher than 99.06, 97.70 and 100.07% for hydrocodone, norhydrocodone and hydromorphone. The intra-and inter-day precisions were <5.80, 5.90 and 3.02% for hydrocodone, norhydrocodone and hydromorphone. The method was accurate, sensitive and simple and was successfully applied to a pharmacokinetic study after a single oral administration of hydrocodone bitartrate at a dose of 5 mg in 12 healthy Chinese volunteers.
引用
收藏
页码:567 / 574
页数:8
相关论文
共 50 条
  • [1] Simultaneous Determination of Hydrocodone, and Its Two Metabolites in Human Plasma by HPLC–MS–MS
    Guang-Tao Hao
    Yan Chen
    Rui-Hua Dong
    Heng-Yan Qu
    Yu-Guang Liang
    Yuan-Yuan Li
    Zhuan-Jie Zheng
    Hong-Zhi Gao
    Ze-Yuan Liu
    Chromatographia, 2011, 74 : 567 - 574
  • [2] Determination of caffeine metabolites in human urine by HPLC-MS-MS
    Schneider, H
    Ma, L
    Glatt, HR
    NAUNYN-SCHMIEDEBERGS ARCHIVES OF PHARMACOLOGY, 2002, 365 : R157 - R157
  • [3] A sensitive HPLC-MS-MS method for the determination of raltegravir in human plasma
    Long, Mary C.
    Bennetto-Hood, Chantelle
    Acosta, Edward P.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 867 (02): : 165 - 171
  • [4] HPLC-MS-MS for the Simultaneous Determination of Atorvastatin and Amlodipine in Plasma of Hypertensive Patients
    Yu, Qi
    Hu, Zhe-Yi
    Zhu, Fan-Yuan
    Zhu, Jin-Hui
    Wan, Li-Li
    Li, Yan
    Guo, Cheng
    CHROMATOGRAPHIA, 2011, 73 (3-4) : 257 - 262
  • [5] Simultaneous Determination of Luteolin and Ayanin in Rat Plasma by HPLC-MS-MS and its Application in a Pharmacokinetic Study
    Li, Li
    Liang, Ji-Jun
    Liu, Yu
    Chen, Li-Jiang
    Zhang, Wen-Jun
    Lu, En
    LATIN AMERICAN JOURNAL OF PHARMACY, 2014, 33 (09): : 1475 - 1480
  • [6] Validated HPLC-MS-MS method for determination of azithromycin in human plasma
    Barrett, B
    Borek-Dohalsky, V
    Fejt, P
    Vaingátová, S
    Huclová, J
    Nemec, B
    Jelínek, I
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 383 (02) : 210 - 217
  • [7] HPLC-MS-MS of enterostatin in human CSF and plasma
    Liu, YM
    Prasad, C
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2003, 225 : U117 - U117
  • [8] Simultaneous determination of pioglitazone and its two active metabolites in human plasma by LC-MS/MS
    Lin, ZPJ
    Ji, WH
    Desai-Krieger, D
    Shum, LY
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 33 (01) : 101 - 108
  • [9] An HPLC-MS-MS method for the simultaneous determination of diazepam and its metabolites in liver and in fly larvae sampled from a putrefied cadaver
    Button, J
    Sanderson, H
    Lee, T
    Holt, DW
    THERAPEUTIC DRUG MONITORING, 2005, 27 (02) : 222 - 222
  • [10] Simultaneous determination of atorvastatin and its metabolites in human plasma by UPLC-MS/MS
    Cai, Liyun
    Zheng, Zhijie
    Wang, Xipei
    Tang, Lan
    Mai, Liping
    He, Guodong
    Leib, Heping
    Zhong, Shilong
    ANALYTICAL METHODS, 2017, 9 (06) : 1038 - 1045