Modal transformation obtained from Clarke's matrix - Asymmetrical three-phase case

被引:0
|
作者
Prado, A. J. [1 ]
Pissolato Filho, J. [3 ]
Kurokawa, S. [2 ]
Bovolato, L. F. [2 ]
机构
[1] Univ Estadual Londrina, DEE CTU UEL, Dept Elect Engn, Londrina, Brazil
[2] Univ Estadual Paulista, Dept Elect Engn, DEE FEIS UNESP, Paulista, Brazil
[3] Campinas Univ State, Dept Elect Engn, DSCE FEEC UNICAMP, BR-13081970 Campinas, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Clarke's matrix; eigenvector; eigenvalue; frequency; mode domain; transformation matrix; transmission lines;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Some constant matrices can be used as phase-mode transformation matrices for transposed three-phase transmission tines. Clarke's matrix is one of these options. Its application as a phase-mode transformation matrix for untransposed three-phase transmission lines has been analyzed through error and frequency scan comparisons. Based on an actual untransposed asymmetrical three-phase transmission line example, a correction procedure is applied searching for better results from the Clarke's matrix applicaton as a phase-mode transformation matrix. The error analyses are carried out using Clarke's matrix and the new transformation matrices obtained from the correction procedure. Applying Clarke's matrix, the relative errors of the eigenvalue matrix elements can be considered negligible and the relative values of the off-diagonal elements are significant. If the the corrected transformation matrices are used, the relative values of the off-diagonal elements are decreased. Based on the results of these analyses, the homopolar mode is more sensitive to the frequency influence than the two other modes related to three-phase lines.
引用
收藏
页码:220 / +
页数:2
相关论文
共 50 条
  • [1] Application of Clarke's transformation to the modal analysis of asymmetrical single-circuit three-phase line configurations
    Faria, JAB
    EUROPEAN TRANSACTIONS ON ELECTRICAL POWER, 2000, 10 (04): : 225 - 231
  • [2] Clarke Transformation Solution of Asymmetrical Transients in Three-Phase Circuits
    Bellan, Diego
    ENERGIES, 2020, 13 (19)
  • [3] Interrelation of a clarke and fortescue transformation for the three-phase asymmetrical electrical network
    Bialobrzheskyi, O.V.
    Vlasenko, R.V.
    Naukovyi Visnyk Natsionalnoho Hirnychoho Universytetu, 2016, (05): : 67 - 74
  • [4] Corrected transfom-iation matrices from Clarke's matrix -Asymmetrical three-phase lines applications
    Prado, A. J.
    Pissolato Filho, J.
    Kurokawa, S.
    Bovolato, L. F.
    2006 POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-9, 2006, : 850 - +
  • [5] Three-phase adaptive frequency measurement based on Clarke's transformation
    Manana, Mario
    Ortiz, Alfredo
    Eguiluz, Luis Ignacio
    Renedo, Carlos J.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2006, 21 (03) : 1101 - 1105
  • [6] On the modal analysis of asymmetrical three-phase transmission lines using standard transformation matrices
    Faria, JAB
    Briceno, JH
    IEEE TRANSACTIONS ON POWER DELIVERY, 1997, 12 (04) : 1760 - 1765
  • [7] Time Domain Analyses for Three-phase Lines with Corrected Modal Transformation Matrix
    Prado, A. J.
    Kurokawa, S.
    Costa, E. C. M.
    Pissolato Filho, J.
    Bovolato, L. F.
    2012 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2012,
  • [8] Single Real Transformation Matrix Application for Asymmetrical Three-phase Line Transient Analyses
    Prado, A. J.
    Kurokawa, S.
    Pissolato Filho, J.
    Bovolato, L. F.
    2008 IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXPOSITION: LATIN AMERICA, VOLS 1 AND 2, 2008, : 243 - +
  • [9] Clarke's Matrix Correction Procedure for Non Transposed Three-phase Transmission Lines
    Prado, A. J.
    Pissolato Filho, J.
    Kurokawa, S.
    Bovolato, L. F.
    2008 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-11, 2008, : 5592 - +
  • [10] Modal transformation analyses for double three-phase transmission lines
    do Prado, Afonso Jose
    Pissolato Filho, Jose
    Kurokawa, Sergio
    Bovolato, Luiz Fernando
    IEEE TRANSACTIONS ON POWER DELIVERY, 2007, 22 (03) : 1926 - 1936