Technological capabilities of surface layers formation on implant made of Ti-6Al-4V ELI alloy

被引:25
|
作者
Kiel-Jamrozik, Marta [1 ]
Szewczenko, Janusz [1 ]
Basiaga, Marcin [1 ]
Nowinska, Katarzyna [2 ]
机构
[1] Silesian Tech Univ, Fac Biomed Engn, Dept Biomat & Med Devices Engn, PL-41800 Zabrze, Poland
[2] Silesian Tech Univ, Fac Min & Geol, Inst Appl Geol, Gliwice, Poland
关键词
corrosion resistance; ion infiltration; metallic biomaterials; surface modification; titanium alloys; TITANIUM-ALLOYS; TI6AL4V;
D O I
10.5277/ABB-00065-2014-03
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Purpose: The aim of the presented research was to find a combination of surface modification methods of implants made of the Ti-6Al-4V ELI alloy, that lead to formation of effective barrier for metallic ions that may infiltrate into solution. Methods: To this end, the following tests were carried out: roughness measurement, the voltamperometric tests (potentiodynamic and potentiostatic), and the ion infiltration test. Results: The electropolishing process resulted in the lowering of surface roughness in comparison with mechanical treatment of the surface layer. The anodization process and steam sterilization increased corrosion resistance regardless of the mechanical treatment or electropolishing. The crevice corrosion tests revealed that independent of the modification method applied, the Ti-6Al-4V ELI alloy has excellent crevice corrosion resistance. The smallest quantity of ions infiltrated to the solution was observed for surface modification consisting in the mechanical treatment and anodization with the potential of 97 V. Conclusions: Electric parameters determined during studies were the basis for effectiveness estimation of particular surface treatment methods. The research has shown that the anodization process significantly influences the pitting corrosion resistance of the Ti-6Al-4V ELI alloy independent of the previous surface treatment methods (mechanical and electrochemical). The surface layer after such modification is a protective barrier for metallic ions infiltrated to solution and protects titanium alloy against corrosive environment influence.
引用
收藏
页码:31 / 37
页数:7
相关论文
共 50 条
  • [1] Formation of surface layers on Ti-6Al-4V titanium alloy by laser alloying
    Filip, R
    Sieniawski, J
    Pleszakov, E
    SURFACE ENGINEERING, 2006, 22 (01) : 53 - 57
  • [2] Machining of Ti-6Al-4V ELI Alloy: A brief review
    Anurag, R. Kumar
    Roy, S.
    Joshi, K. K.
    Sahoo, A. K.
    Das, R. K.
    3RD INTERNATIONAL CONFERENCE ON MATERIALS AND MANUFACTURING ENGINEERING 2018, 2018, 390
  • [3] Fracture characteristics of fatigued Ti-6Al-4V ELI as an implant material
    Akahori, Toshikazu
    Niinomi, Mitsuo
    Materials Science and Engineering A, 1998, A243 (1-2): : 237 - 243
  • [4] Fracture characteristics of fatigued Ti-6Al-4V ELI as an implant material
    Akahori, T
    Niinomi, M
    MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 1998, 243 (1-2): : 237 - 243
  • [5] On the hot workability of ELI grade titanium alloy Ti-6Al-4V
    Murty, SVSN
    Rao, BN
    Kashyap, BP
    ZEITSCHRIFT FUR METALLKUNDE, 2001, 92 (05): : 473 - 476
  • [6] Electrochemical Properties of Ti-6Al-4V ELI Alloy after Anodization
    Kiel, Marta
    Szewczenko, Janusz
    Marciniak, Jan
    Nowinska, Katarzyna
    INFORMATION TECHNOLOGIES IN BIOMEDICINE, ITIB 2012, 2012, 7339 : 369 - 378
  • [7] Evaluation of electrochemical properties of modified Ti-6Al-4V ELI alloy
    Szewczenko, Janusz
    Pochrzast, Magdalena
    Walke, Witold
    PRZEGLAD ELEKTROTECHNICZNY, 2011, 87 (12B): : 177 - 180
  • [8] Influence of a Femtosecond Laser Surface Modification on the Fatigue Behavior of Ti-6Al-4V ELI Alloy
    dos Santos, Alan
    Campanelli, Leonardo Contri
    Carvalho Pereira da Silva, Paulo Sergio
    Vilar, Rui
    Martins de Almeida, Maria Amelia
    Kuznetsov, Alexei
    Achete, Carlos Alberto
    Bolfarini, Claudemiro
    MATERIALS RESEARCH-IBERO-AMERICAN JOURNAL OF MATERIALS, 2019, 22 (04):
  • [9] Enhancing the durability of spinal implant fixture applications made of Ti-6Al-4V ELI by means of cavitation peening
    Takakuwa, Osamu
    Nakai, Masaaki
    Narita, Kengo
    Niinomi, Mitsuo
    Hasegawa, Kazuhiro
    Soyama, Hitoshi
    INTERNATIONAL JOURNAL OF FATIGUE, 2016, 92 : 360 - 367
  • [10] Evaluation of corrosion behavior of surface modified Ti-6Al-4V ELI alloy in hanks solution
    Tamilselvi, S.
    Raman, V.
    Rajendran, N.
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2010, 40 (02) : 285 - 293