Correlation between anatomical parameters of intertubercular sulcus and retroversion angle of humeral head

被引:1
|
作者
Pan, Zhaoxun [1 ]
Chen, Jun [2 ]
Qu, Lianjun [1 ]
Cui, Yan [1 ]
Sun, Chao [1 ]
Zhang, Hongxin [1 ]
Yang, Xiaoming [1 ]
Guan, Qingli [1 ]
机构
[1] Eighty Ninth Hosp Peoples Liberat Army, Dept Joint Surg, Weifang 261021, Peoples R China
[2] Sanat 71521 Army Retired Cadres, Xinxiang 453000, Henan, Peoples R China
关键词
Intertubercular sulcus; position angle of intertubercular sulcus; retroversion angle of humeral head; measurement; correlation; PROXIMAL HUMERUS; SHOULDER ARTHROPLASTY; PROSTHETIC DESIGN; BICIPITAL GROOVE; ELBOW SURGERY; HEMIARTHROPLASTY; FRACTURES; ORIENTATION; GEOMETRY;
D O I
暂无
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objective: To obtain anatomical data on intertubercular sulcus of humerus, evaluate the correlation between intertubercular sulcus and retroversion angle of humeral head, to guide the positioning of torsion angle of prosthesis during total shoulder arthroplasty and provide references for shoulder prosthesis design. Methods: Using a Siemens Ultrahigh speed 64- rows multi-slices spiral CT scanner and 20 dried adult humeral specimens (intact specimen, no fractures or pathological damage), of these, left lateral in 10 cases, right lateral in 10 cases, male or female all inclusive, specimens are all provided by Anatomy Department of Weifang Medical College, scan ranged from the highest point of humeral head to the distal ends of trochlea. And scanned data were subjected to statistical analysis. Results: There is a linear correlation between the distance from intertubercular sulcus to central axis line of humeral head, position angle of intertubercular sulcus and retroversion angle of humeral head at the beginning slice of intertubercular sulcus. There is a linear correlation between position angle of intertubercular sulcus and retroversion angle of humeral head at the slice of surgical neck. Conclusion: There is a linear correlation between position of intertubercular sulcus and retroversion angle of humeral head, in total shoulder arthroplasty, using intertubercular sulcus as anatomical landmark will help to accurately position torsion angle of individualized prosthesis. Position angle of intertubercular sulcus is an objective, flexible positioning indicator.
引用
收藏
页码:4837 / 4845
页数:9
相关论文
共 50 条
  • [1] Correlation between the retroversion of the humeral head and the orientation of the intertubercular sulcus: a CT scan anatomical study
    Guenoun, Daphne
    Le Corroller, Thomas
    Lagier, Aude
    Pauly, Vanessa
    Champsaur, Pierre
    SURGICAL AND RADIOLOGIC ANATOMY, 2015, 37 (04) : 357 - 361
  • [2] Correlation between the retroversion of the humeral head and the orientation of the intertubercular sulcus: a CT scan anatomical study
    Daphne Guenoun
    Thomas Le Corroller
    Aude Lagier
    Vanessa Pauly
    Pierre Champsaur
    Surgical and Radiologic Anatomy, 2015, 37 : 357 - 361
  • [3] Correlation study on anatomical parameters of bicipital groove and retroversion angle of humeral head
    Pan, Zhaoxun
    Qu, Lianjun
    Cui, Yan
    Guan, Qingli
    Zhang, Hongxin
    Yang, Xiaoming
    Sun, Chao
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2016, 9 (02): : 1354 - 1360
  • [4] Measurement of the humeral head retroversion angle A new radiographic method
    Volkan Öztuna
    Hakan Öztürk
    Metin M. Eskandari
    Fehmi Kuyurtar
    Archives of Orthopaedic and Trauma Surgery, 2002, 122 : 406 - 409
  • [5] Measurement of the humeral head retroversion angle -: A new radiographic method
    Öztuna, V
    Öztürk, H
    Eskandari, MM
    Kuyurtar, F
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2002, 122 (07) : 406 - 409
  • [6] Linear relationship between lateralization of the bicipital groove and humeral retroversion and its link with the biepicondylar humeral line. Anatomical study of seventy cadaveric humerus scans
    Andrin, Julien
    Pottecher, Pierre
    Viard, Brice
    Baulot, Emmanuel
    Trouilloud, Pierre
    Martz, Pierre
    INTERNATIONAL ORTHOPAEDICS, 2017, 41 (07) : 1431 - 1434
  • [7] Linear relationship between lateralization of the bicipital groove and humeral retroversion and its link with the biepicondylar humeral line. Anatomical study of seventy cadaveric humerus scans
    Julien Andrin
    Pierre Pottecher
    Brice Viard
    Emmanuel Baulot
    Pierre Trouilloud
    Pierre Martz
    International Orthopaedics, 2017, 41 : 1431 - 1434
  • [8] An Analysis of the Correlation between Humeral Head Anterior Glide Posture and Elbow Joint Angle, Forward Head Posture and Glenohumeral Joint Range of Motion
    Gong, Wontae
    Jun, Ilsub
    Choi, Yoorim
    JOURNAL OF PHYSICAL THERAPY SCIENCE, 2013, 25 (04) : 489 - 491
  • [9] Correlation between mineralization and mechanical strength of the subchondral bone plate of the humeral head
    Zumstein, Valentin
    Kraljevic, Marko
    Wirz, Dieter
    Huegli, Rolf
    Mueller-Gerbl, Magdalena
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2012, 21 (07) : 887 - 893
  • [10] CORRELATION BETWEEN SPECTRAL PARAMETERS AND VALENCE ANGLE IN PHOSPHINES
    BELSKII, VE
    ROMANOV, GV
    POZHIDAEV, VM
    PUDOVIK, AN
    ZHURNAL OBSHCHEI KHIMII, 1980, 50 (06): : 1222 - 1225