Application of XMR 2D-3D registration to cardiac interventional guidance

被引:0
|
作者
Rhode, KS [1 ]
Hill, DLG
Edwards, PJ
Hipwell, J
Rueckert, D
Sanchez-Ortiz, GI
Hegde, S
Rahunathan, V
Razavi, R
机构
[1] Kings Coll London, Div Imaging Sci, London WC2R 2LS, England
[2] Univ London Imperial Coll Sci Technol & Med, Dept Comp Sci, London SW7 2BZ, England
来源
MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2003, PT 1 | 2003年 / 2878卷
关键词
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
We describe a registration and tracking technique to integrate cardiac x-ray images and cardiac magnetic resonance (MR) images acquired from a combined x-ray and MR interventional suite (XMR). Optical tracking is used to determine the transformation matrices relating MR and x-ray image coordinates. Calibration and tracking enable us to combine x-ray projection images with registered projection MR images from a volume acquisition, and to display 3D reconstructions of catheters within the MR volume. Registration errors were assessed using phantom experiments. Errors in the combined projection images (2D root mean square target registration error - RMS TRE) were found to be 2.4 - 4.2 mm, and the errors in the integrated volume representation (3D RMS TRE) were found to be 4.6 - 5.1 mm. These errors are clinically acceptable for alignment of images of the heart and the great vessels. We demonstrate that our technique can be used to guide catheters and to combine electrical and mechanical information in the context of the patient-specific anatomy for a patient undergoing cardiac radio-frequency (RF) ablation.
引用
收藏
页码:295 / 302
页数:8
相关论文
共 50 条
  • [1] 2D-3D registration of coronary angiograms for cardiac procedure planning and guidance
    Turgeon, GA
    Lehmann, G
    Guiraudon, G
    Drangova, M
    Holdsworth, D
    Peters, T
    MEDICAL PHYSICS, 2005, 32 (12) : 3737 - 3749
  • [2] 2D-3D registration for interventional procedures: A clinical perspective
    Klingenbeck, K
    BIOMEDICAL IMAGE REGISTRATION, 2003, 2717 : 212 - 213
  • [3] 2D-3D Registration of Cardiac Images Using Catheter Constraints
    Truong, M. V. N.
    Aslam, A.
    Ginks, M.
    Rinaldi, C. A.
    Rezavi, R.
    Penney, G. P.
    Rhode, K. S.
    CINC: 2009 36TH ANNUAL COMPUTERS IN CARDIOLOGY CONFERENCE, 2009, 36 : 605 - +
  • [4] A robust technique for 2D-3D registration
    Gong, Ren Hui
    Abolinaesumi, Purang
    Stewart, James
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 714 - 717
  • [5] Standardized evaluation of 2D-3D registration
    van de Kraats, EB
    Penney, GP
    Tomazevic, D
    van Walsum, T
    Niessen, WJ
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2004, PT 1, PROCEEDINGS, 2004, 3216 : 574 - 581
  • [6] A Flexible 2D-3D Parametric Image Registration Algorithm for Cardiac MRI
    Ma, L. W. Lorraine
    Ebrahimi, Mehran
    IMAGE ANALYSIS AND RECOGNITION (ICIAR 2016), 2016, 9730 : 661 - 671
  • [7] Interventional Digital Tomosynthesis from a Standard Fluoroscopy System Using 2D-3D Registration
    Alhrishy, Mazen
    Varnavas, Andreas
    Carrell, Tom
    King, Andrew
    Penney, Graeme
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION (MICCAI 2013), PT III, 2013, 8151 : 98 - 105
  • [8] Interventional digital tomosynthesis from a standard fluoroscopy system using 2D-3D registration
    Alhrishy, Mazen
    Varnavas, Andreas
    Carrell, Tom
    King, Andrew
    Penney, Graeme
    MEDICAL IMAGE ANALYSIS, 2015, 19 (01) : 137 - 148
  • [9] Efficient framework for deformable 2D-3D registration
    Fluck, Oliver
    Aharon, Shmuel
    Khamene, Ali
    MEDICAL IMAGING 2008: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, PTS 1 AND 2, 2008, 6918
  • [10] Increasing the Automation of a 2D-3D Registration System
    Varnavas, Andreas
    Carrell, Tom
    Penney, Graeme
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2013, 32 (02) : 387 - 399